Models: WRH605IWRH608I • WRH908IREHR6 • REHR9 • RRE634 • RRE635 • RRE934
These cooker hoods are domestic appliances which have been manufactured and tested to comply with
Australian and New Zealand Standard AS/NZS 3350.2.31.
13427_Rangehood_Electrolux.indd 1
13427_Rangehood_Electrolux.indd 1
13427_Rangehood_Electrolux.indd 1
13427_Rangehood_Electrolux.indd 113427_Rangehood_Electrolux.indd 1 3/11/05 6:28:19PM
3/11/05 6:28:19PM
3/11/05 6:28:19PM
3/11/05 6:28:19PM
RETRACTABLE RANGEHOOD
Safety Warnings
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision or insruction
concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
Ensure the cooker hood is switched off before carrying out maintenance, to avoid any possibility of electric shock.
Grease lters must be removed every four weeks (maximum) for cleaning to reduce the risk of re.
Do not ambé under the cooker hood.
This cooker hood is not recommended for barbeques.
The exhaust air from the cooker hood must not be discharged into any heating ue, which may carry combustion
products from other sources.
Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for the purpose.
There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning
gas or other fuels.
Always cover lit gas burners with pots or pans when the cooker hood is in use.
Always switch off gas burners before you remove pots or pans.
Cleaning
Wipe the cooker hood body and ue with a sponge or soft cloth soaked in warm soapy water. Do not use oven cleaners
or other abrasive materials.
Electrical Connection
Check that the mains voltage matches with the voltage on the data plate inside the cooker hood.
Check that the installation complies with standards of local gas and electricity authorities.
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similarly quali ed
person in order to avoid a hazard.
Accessories
Use 125mm round exhaust ducting for best performance.
When using exible duct always install duct with the wire helix pulled taut to minimise pressure loss.
Try to keep exhaust duct short and straight.
Keep bends in the exhaust duct to a minimum.
Do not reduce the size or restrict exhaust duct.
P1
13427_Rangehood_Electrolux.indd 2
CAUTION: Accessible parts may become hot when used with cooking appliance.
Regulations concerning the discharge of air have to be fulfilled.
Please read instructions carefully. Service calls resulting from incorrect installation will be charged for.
Exhaust air from the Rangehood must not be discharged into any heating fl ue which may carry
combustion products from other sources. In addition, exhaust air must not be discharged into a wall
cavity, unless the cavity is designed for the purpose. Adequate ventilation of the room must
be ensured when the Rangehood is operating simultaneously with appliances burning gas or
other fuels. Installation must comply in all respects with your gas and electrical authorities. This
Rangehood is an indoor domestic appliance, and has been manufactured and tested to comply with
Australian and New Zealand Standard AS/NZS 3350.2.31
It is recommended that the unit be positioned as close as possible to 600mm (electric hobs),
650mm (gas hobs), and no further from the hob than 800mm. The unit becomes less effective
as the distance from the cooking surface to the hood increases.
FIXING POINT DIMENSIONS - 600mm Retractable cooker hood
FIXING POINT DIMENSIONS - 900mm Retractable
cooker hood
INSTALLATION INSTRUCTIONS
600650
GAS
ELECTRIC
Ducting hole
cover
Duct Spigot
DUCTING INSTALLATION
When installing with ducting pipe the Duct
spigot must be fitted to the ducting hole
on top of the body of the cooker hood
RECIRCULATING INSTALLATION
(For Models: WRH608, RRE634, RRE635, WRH908
& RRE934)
When installed in recirculating mode the
ducting hole cover be fittedmust
P2
13427_Rangehood_Electrolux.indd 3
13427_Rangehood_Electrolux.indd 3
13427_Rangehood_Electrolux.indd 3
13427_Rangehood_Electrolux.indd 313427_Rangehood_Electrolux.indd 3 3/11
3/11
3/11
3/11
OPERATION GUIDE & INSTALLATION INSTRUCTIONS
The maximum space between the wall and screw cap is 5mm.