Altronix 6062 Bruksanvisning

Läs nedan 📖 manual på svenska för Altronix 6062 (2 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 6 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
6062 - Multi-purpose Timer
Overview:
Model 6062 programmable timer is suitable for many functions that require a timed operation e.g. Access Control Applications,
Siren/Bell Cut Off Module, Dialer Delay, Guard Tour Supervisory Timer, etc. Some optional functions include: One Shot, Delayed
Release, Delayed Operate, Delayed Pulse and Pulser/Flasher. A new feature has been added which provides a momentary relay acti-
vation at the end of a desired timing cycle. This feature eliminates the need for having to use two (2) timers to achieve this function.
Specifications:
Installation Instructions:
1. Mount 6062 in desired location/enclosure.
2. Set proper DC Input Voltage Dip Switch 3: 12VDC ON, 24VDC OFF.
3. Refer to and for desired functions (e.g.: Timing, Trigger, Pulse)Dip Switch Selection Jumper Selection Tables
4. Measure DC input voltage before powering device to ensure proper operation.
5. Refer to and for desired wiring connections.Terminal Identification Table Typical Applications g. 1 thru g. 8.
Note: When triggering via a N.O. (normally open), momentary or maintained trigger, connect the dry contact trigger to Pos (+)
and TRG terminals. When triggering via a N.C. (normally closed), momentary or maintained trigger, connect the trigger to Neg. (-)
and TRG terminals and install a resistor [for 12VDC - 2K (2,000 ohm) or for 24VDC - 4.7K (4,700 ohm)]
between the Pos (+) and TRG terminals (Fig. 8).
6. Enable the reset features:
- Cut J3 when power is removed the timer will reset and not re-trigger when power is restored unless a new trigger is applied.
The closed trigger and delayed pulse options will not operate if the reset feature is desired.Note:
Dip Switch Selection Table:
Dip # Off On
1 Relay energizes at the start of timing cycle.* Relay energizes at the end of timing cycle.*
2 1-60 Minutes timing range (trimpot adjustable). 1-60 Seconds timing range (trimpot adjustable).
3 24VDC operating voltage. 12VDC operating voltage.
4 Timing begins immediately upon trigger input. Timing starts after removal of trigger input.
* When relay energizes (LED is on) [N.O. & C] switch from open to close and [N.C. & C] switch from close to open.
Jumper Selection Table:
Number Function/Description
J1 Cutting J1 selects the pulser/flasher mode. Relay will flip ON and OFF
continuously in equally set timed intervals when timer is powered up.
J2 Cutting J2 puts timer in delayed output mode. Relay will pulse for 1 second at
the end of a preset timing cycle. *Dip Switch 1 must be ON for this function.
J3 6062 will go through an initial timing cycle when first powered up unless J3 is cut.
If J3 is cut, timing can only be initiated via TRG terminal.
Terminal Identification:
Terminal
Legend Function/Description
TRG Applying a positive voltage will activate timing cycle.
Trigger voltage range: 7-12VDC at 12 volt setting, 15-24VDC at 24 volt setting.
--- , + Connect 12 or 24VDC filtered and regulated voltage. Refer to for voltage setting.Dip Switch Selection Table
N.O., C, N.C. Dry form “C” relay contacts are rated 8 amp at 120VAC/28VDC.
•12VDCor24VDCoperationisselectable.
•Quickandextremelyaccuratetimerangeadjustmentfrom
1 sec. to 60 min.
•LEDindicatesrelayisenergized.
•Form“C”relaycontactsare8ampat120VAC/28VDC.
•CurrentDraw:Stand-by3mA,RelayEnergized40mA.
•TriggersviapositiveDC(+)voltage,drycontactclosure,
or removal of contact closure.
•Selectablerelayactivationatthestartorendofthe
timing cycle.
•One(1)secondmomentaryrelayactivationattheendof
the timing cycle (eliminates the need to use two (2) timers
for this function).
•Built-inresetfeaturewhichcancelstimingcycle.
•Repeat(pulser/flasher)mode.
•SnapTrackcompatible(orderAltronixmodel#ST3)
•DINRailMountversionavailable
 (orderAltronixmodel#DTMR1).
Boarddimensions:3”Lx2.5”Wx.75”H(approximate)
6062 Typical Applications:
Fig. 1 - Timed Door Annunciator:
ForthisapplicationSwitch#1andSwitch#4
should be in the OFF position.
Fig. 5 - Timed Door Strike:
ForthisapplicationSwitch#1shouldbeintheOFF
positionandSwitch#4shouldbeintheONposition.
Fig. 2 - Guard Tour Supervisory Timer:
ForthisapplicationSwitch#1andSwitch#4
should be in the OFF position.
Fig. 6 - Timed Shunt for a Door: Use to bypass alarm contacts.
ForthisapplicationSwitch#1shouldbeintheOFF
positionandSwitch#4shouldbeintheONposition.
Fig. 3 - Swinger Eliminator:
ForthisapplicationSwitch#1shouldbeintheOFFposition
andSwitch#4shouldbeintheONposition.
Fig. 7 - Bell Cut Off Timer:
ForthisapplicationSwitch#1shouldbeintheONpositionand
Switch#4isnotusedinthisapplication.
Fig. 8 - Closed Circuit Trigger Option:
TRG -- +
Closed
Ci uitrc
Contact
Pull up
Resistor
Power
Supply
+
---
Fig. 4 - Delay Timer: Use for Door Ajar Alarm, Delayed
Activation of Digital Dialer, Defrost Cycle Timer, etc...
ForthisapplicationSwitch#1shouldbeintheONposition
andSwitch#4isnotusedinthisapplication.
MEMBER
For this application a resistor [for 12VDC - 2K (2,000 ohm)
or for 24VDC - 4.7K (4,700 ohm)] must be installed as shown
(resistor not supplied).
Altronixisnotresponsibleforanytypographicalerrors.
14058th Street,Brooklyn,New York11220USA,718-567-8181,fax:718-567-9056
website:www.altronix.com,e-mail:info@altronix.com, LifetimeWarranty, MadeinU.S.A.
II6062 - Rev. 032211 C22K
TRG -- + NO C NC
1
ON
ON
1 2 3 4
OF F
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELAY CONTROL
CHIME
Pos (+) and Neg ( --
)
terminals constant
12VDC or 24VDC
Normally Open
Door Contacts
+
---
+
---
4
3
2
1
J3
CUT J2 FOR DELAY PULSE J2
CUT J1 FOR REPEAT J1
45 60
TRG -- + NO C NC
1
ON
ON
1 2 3 4
OF F
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELAY CONTROL
Pos (+) and Neg ( --
)
terminals constant
12VDC or 24VDC
Normally Open
Door Contacts
Door Strike
+
---
+ ---
4
3
2
1
J3
CUT J2 FOR DELAY PULSE J2
CUT J1 FOR REPEAT J1
45 60
TRG -- + NO C NC
1
ON
ON
1 2 3 4
OF F
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELAY CONTROL
DIALER OR
TRANSMITTER
Pos (+) and Neg ( )--
terminals constant
12VDC or 24VDC
Normally Open
Switch Contacts
+
---
4
3
2
1
J3
CUT J2 FOR DELAY PULSE J2
CUT J1 FOR REPEAT J1
45 60
TRG -- + NO C NC
1
ON
ON
1 2 3 4
OF F
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELAY CONTROL
Pos (+) and Neg ( --
)
terminals constant
12VDC or 24VDC
Door Contacts
Protective
Ci uitrc
+
---
4
3
2
1
J3
CUT J2 FOR DELAY PULSE J2
CUT J1 FOR REPEAT J1
45 60
Normally Open
Switch Contacts
TRG -- + NO C NC
1
ON
ON
1 2 3 4
OF F
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELAY CONTROL
Closed
Ci uitrc
Zone on
Control Panel
Pos (+) and Neg ( --
)
terminals constant
12VDC or 24VDC
Protective
Ci uitrc
+
---
4
3
2
1
J3
CUT J2 FOR DELAY PULSE J2
CUT J1 FOR REPEAT J1
45 60
TRG -- + NO C NC
1
ON
ON
1 2 3 4
OF F
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELAY CONTROL
Use appropriate contacts
to porting devicesre
Normally Open
Triggering Device
Pos (+) and Neg ( --
)
terminals constant
12VDC or 24VDC
+
---
4
3
2
1
J3
CUT J2 FOR DELAY PULSE J2
CUT J1 FOR REPEAT J1
45 60
TRG -- + NO C NC
1
ON
ON
1 2 3 4
OF F
15
CUT J3 FOR RESET
ON POWER-UP
TRIG CONTROL
12V / 24V
SEC. / MIN.
RELAY CONTROL
Bell
or
Siren
+
---
4
3
2
1
J3
CUT J2 FOR DELAY PULSE J2
CUT J1 FOR REPEAT J1
45 60
Bell
Output
Control Panel
12VDC or 24VDC