AnD UA-704 Bruksanvisning

Läs nedan 📖 manual på svenska för AnD UA-704 (15 sidor) i kategorin Blodtrycksmätare. Denna guide var användbar för 6 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/15
Digital Blood Pressure Monitor
Model UA-704
Instruction Manual
Original
Manuel d’instructions
Traduction
Manual de Instrucciones
Traducción
Manuale di Istruzioni
Traduzione
使用手冊
翻譯
1WMPD4000735E
English 1
Contents
Dear Customers ............................................................................... 1
Preliminary Remarks ........................................................................ 1
Precautions ....................................................................................... 2
Parts Identification .......................................................................... 3
Symbols .................................................................................. 4
Using The Monitor ........................................................................... 5
Installing / Changing The Battery ........................................ 5
Selecting The Correct Cuff ................................................... 6
Applying The Arm Cuff ........................................................ 7
How To Take Proper Measurements ..................................... 7
Measurement ............................................................................... 7
After Measurement ...................................................................... 7
Measurement .................................................................................... 8
Notes For Proper Measurement .................................................. 9
What Is An Irregular Heartbeat? .................................................... 10
About Blood Pressure .................................................................... 10
What Is Blood Pressure? ............................................................ 10
What Is Hypertension And How Is It Controlled? .................... 10
Why Measure Blood Pressure At Home? .................................. 11
WHO Blood Pressure Classification .......................................... 11
Blood Pressure Variations ......................................................... 11
Troubleshooting ............................................................................ 12
Maintenance ................................................................................... 12
Technical Data ............................................................................... 13
Dear Customers
Congratulations on purchasing a state-of-the-art A&D blood pressure
monitor, one of the most advanced monitors available today. Designed for
ease of use and accuracy, this device will facilitate your daily blood
pressure regimen.
We recommend that you read through this manual carefully before
using the device for the first time.
Preliminary Remarks
This device conforms to the European Directive 93/42 EEC for Medical
Products. This is made evident by the mark of conformity.
(0123: The reference number to the involved notified body)
The device is designed for use on adults only, not newborns or infants.
Environment for use: The device is for use in the home healthcare
environment.
This device is designed to measure blood pressure and pulse rate of
people for diagnosis.
English 2
Precautions
Precision components are used in the construction of this device.
Extremes in temperature, humidity, direct sunlight, shock or dust should
be avoided.
Clean the device and cuff with a dry, soft cloth or a cloth dampened with
water and a neutral detergent. Never use alcohol, benzene, thinner or
other harsh chemicals to clean the device or cuff.
Avoid tightly folding the cuff or storing the hose tightly twisted for long
periods, as such treatment may shorten the life of the components.
The device and cuff are not water-resistant. Prevent rain, sweat and
water from soiling the device and cuff.
Measurements may be distorted if the device is used close to television,
microwave oven, cellular telephone, X-ray or other devices with strong
electrical fields.
Used equipment, parts and battery are not treated as ordinary household
waste, and must be disposed of according to the applicable local
regulations.
When reusing the device, confirm that the device is clean.
Do not modify the device. It may cause accidents or damage to the
device.
To measure blood pressure, the arm must be squeezed by the cuff hard
enough to temporarily stop blood flow through the artery. This may cause
pain, numbness or a temporary red mark to the arm. This condition will
appear especially when measurement is repeated successively. Any
pain, numbness, or red marks will disappear with time.
Contraindications
The following are precautions for proper use of the device.
Do not apply the cuff on an arm with another medical electrical
equipment attached. The equipment may not function properly.
People who have a severe circulatory deficit in the arm must consult a
doctor before using the device, to avoid medical problems.
Do not self-diagnose the measurement results and start treatment by
yourself. Always consult your doctor for evaluation of the results and
treatment.
Do not apply the cuff on an arm with an unhealed wound.
Do not apply the cuff on an arm receiving an intravenous drip or blood
transfusion. It may cause injury or accidents.
Do not use the device where flammable gases such as anesthetic
gases are present. It may cause an explosion.
Do not use the device in highly concentrated oxygen environments,
such as a high-pressure oxygen chamber or an oxygen tent. It may
cause a fire or explosion.