Apc Back-UPS BN450M Bruksanvisning
Läs nedan 📖 manual på svenska för Apc Back-UPS BN450M (12 sidor) i kategorin UPS. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/12

Safety and General Information
Inspect the package contents upon receipt. Notify the carrier and
dealer if there is any damage.
SAVE THESE INSTRUCTIONS - This section contains important
instructions that should be followed during installation and maintenance
of the UPS and batteries.
Inventory
DANGER
HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH
•This UPS is intended for indoor use only.
•Do not operate this UPS in direct sunlight, in contact with fluids, or where there is excessive
dust or humidity.
•Connect the UPS power cable directly to a wall outlet.
•Be sure the air vents on the UPS are not blocked. Allow adequate space for proper ventilation.
Failure to follow these instructions will result in death or serious injury.
bu462a
User Manual Back-UPS™
BE425M/425M-LM, BN450M/450M-CA

Back-UPS BE425M/425M-LM, BN450M/450M-CA2
Connect the Battery
The Back-UPS is shipped with one battery cable disconnected.
Specifications
Remove the “Stop! Connect the Battery” label
that covers the outlets.
The battery connector is located on the
underside of the unit.
Slide the battery connector handle away from its
disconnected position.
Turn the battery connector to a 90-degree
upright position and push it into the unit.
Model BE425M / BE425M-LM BN450M / BN450M-CA
Input Voltage 120 Vac Nominal
Frequency 50/60 Hz + 1Hz auto-sensing
Brownout Transfers 92 Vac Typical
Over-voltage Transfer 139 Vac Typical
Output UPS Capacity 425 VA, 255 W 450 VA, 255 W
No. of Outlets 6
Battery Backup/Surge Outlets 4 / 2
Total output current 6A
Voltage - On Battery 115 Vac ± 8%
Frequency - On Battery 50/60 Hz + 1 Hz
Transfer Time 4 ms Typical
Protection
and
Filtering
EMI/RFI Filter Full time
AC Input Resettable circuit breaker
Battery Type Sealed, maintenance-free, lead acid, 12V
Average Life 3 - 5 years, the number of discharge cycles, poor
quality AC power, environmental temperature and
humidity may shorten the battery lifetime
Charging Time 8 hours
bu462a
bu463a
bu464a
bu465a

Back-UPS BE425M/425M-LM, BN450M/450M-CA 3
Connect Equipment
.
Turn On the Back-UPS
Press the POWER button. It will illuminate green and a single short beep indicating that
the Back-UPS is on and providing protection for connected equipment.
The Back-UPS battery will charge regardless of whether the Back-UPS is switched on or
off as long as it is connected to AC power. The UPS will have full runtime capability
after the initial 24-hour charging period, connected to AC power.
If the red Building Wiring Fault indicator (located on the end near the power cord) is lit,
your building wiring may present a shock hazard that should be corrected by a qualified
electrician.
Model BE425M / BE425M-LM BN450M / BN450M-CA
Physical Net Weight 5.7 lb (2.6 kg)
Dimensions
LxWxH
9.98 in x 4.13 in x 5.51 in
25.35 cm x 10.5 cm x 14.02 cm
Operating Temperature 32º F to 104º F (0º C to 40º C)
Storage Temperature -4º F to 122º F (–20º C to 50º C)
Operating Relative Humidity 0 to 95% non-condensing humidity
Operating Elevation 0 to 10,000 ft (0 to 3000 m)
Feature Function Suggested Use
Battery Backup +
Surge Protection
Outlets
• Receive power from the battery for a
limited period of time when a power
outage, or brownout condition
occurs.
• Provide protection from power
surges or spikes.
Connect a computer, monitor
and other critical peripheral
devices that need to remain on
during power outages or AC
problems.
Surge Protection
Outlets
• Provide protection from power
surges or spikes. Connect non-critical
peripheral devices (such as
printer, scanner, etc.) that do
not need to remain on during
power outages or AC
problems.
Battery Backup + Surge
Protection Outlets
Surge Protection
Outlets
bu461a
POWER
Button
Ba ck -UPS 450
Surge
bu460a
Building
Wiring
Fault
AC Power
Inlet
Circuit
Breaker
Produktspecifikationer
Varumärke: | Apc |
Kategori: | UPS |
Modell: | Back-UPS BN450M |
Behöver du hjälp?
Om du behöver hjälp med Apc Back-UPS BN450M ställ en fråga nedan och andra användare kommer att svara dig
UPS Apc Manualer

31 Januari 2025

31 Januari 2025

15 Januari 2025

15 Januari 2025

15 Januari 2025

15 Januari 2025

15 Januari 2025

2 Januari 2025

31 December 2025

14 December 2024
UPS Manualer
- UPS AEG
- UPS IKEA
- UPS HP
- UPS Siemens
- UPS LC-Power
- UPS Lenovo
- UPS Tripp Lite
- UPS Energenie
- UPS Voltcraft
- UPS Emerson
- UPS Steren
- UPS Adj
- UPS Digitus
- UPS LevelOne
- UPS Teltonika
- UPS Gys
- UPS Eaton
- UPS Jung
- UPS CyberPower
- UPS Conceptronic
- UPS Block
- UPS Liebert
- UPS Avocent
- UPS Furman
- UPS Minuteman
- UPS Riello
- UPS Maruson
- UPS V7
- UPS Phoenix Contact
- UPS Puls Dimension
- UPS Vanson
- UPS Salicru
- UPS Equip
- UPS Approx
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nyaste UPS Manualer

5 Mars 2025

5 Mars 2025

30 Januari 2025

15 Januari 2025

4 Januari 2025

4 Januari 2025

1 Januari 2025

1 Januari 2025

31 December 2025

31 December 2025