Back-UPS BX650LI
User Guide
™
ON/OFF button
LED status indicator
AD
C
B
Battery connector
AC power inlet
EBattery and surge protected outlets
Fuse
Features
3
F
IEC jumper cable for
PC connection
1Safety and General Information
Inspect the package contents upon receipt. Notify the
carrier and dealer if there is any damage.
Read the following reminders before stalling the UPS. in
• This UPS is inten ded for indo or use only.
• Con nect the UPS power cable directly to a wall outlet. Do not use surge protecto rs or
extension cords.
• When grounding can not be verified, disconnect the equipment from the AC power outlet
before installing or connecting to other equipment. Reconnect the power cord after all
connections are made.
• Servicing of batteries should be performed by Schneider Electric IT (SEIT) Customer
Sup port only.
• When replacing battery the UPS must be OFF, and its AC inlet unplugged.
• Do no t dispose of batteries in a fire. The batteries may explode.
• Do no t open or mutilate batteries. They contain an electrolyte that is toxic and harmful
to the skin and eyes.
• To avoid harmful injury due to energ y hazard, remove wrist watches and jewelry such
as rings when replacing the batteries. Use tools with insulated han dles.
• Replace batteries with the same number an d type of batteries as originally installed in
the equipment.
2Place and Power On
Replace PC's input cord with a jumper cable and use PC's input cord to connect
the UPS.
2
1
3
4
Con nect the battery by pulling the battery handle up,
and then pushing it into the unit.
Press the ON/OFF button to tu rn on the unit.
The green “Power On” indictor co nfirms th at the Back-UPS is on and read y to
pro vid e protection.
The Back-UP S should charger for at least 6 hours to ensure sufficient runtime.
The unit is being charged whenever it is connected to AC power, whether the
unit is turned ON or OFF.
Place the Back-UPS to avoid:
‧Direct sunlight
‧Excessive heat
‧Excessive moisture
For safety operation, please place the unit on the floor.
4
Specifications
Input Voltage / Frequency 230 VAC / 5 6 Hz0 Hz or 0
Brownout Transfer /
Over-voltage Transfer
1 0 VAC, typical / 7
280 VAC, typical
Output UPS Capacity (total) 650 VA / 325 W
Voltage On Battery 230 Vac rms
Frequency - On Battery 50 Hz / 60 Hz Hz±1
Transfer me 6ms typicalTi
Protection AC Input Fuse
Battery Type (maintenance-free) 12V, 7 AH
Typical Recharge Time Hours 4-6
Physical Net Weight . kg 4 2
Dimensions (H x W x D) cm x 1 . cm x cm 14.2 0 1 30
Average Life years. Environmental factors impact battery
life. Elevated temperatures, high humidity,
poor quality mains power, and frequent,
short duration discharges will shorten
battery life.
The battery typically lasts for three to five
The battery in the Back-UPS BX 650LI
Series is not user-replaceable. Contact
SEIT Technical Support for a list of
authorized service centers near you.
APC by Schneider Electric IT Customer
Support Worldwide
For country specific customer support, go to the APC by Schn idere Electric Web site w , w w. .apc com.
Troubleshooting and Service
1 act Schneider Electric stomer Support through the APC by. If the problem persists, cont IT (SEIT) Cu
Schneider Electric Web site, www.apc.com. .
a. Note the model number and serial number . and the date of purchase The model and serial numbers
are located on the rear panel of the unit and are available through the LCD display on select models.
b. Call SEIT Customer Support and a technician will attempt to solve the problem over the phone. If it
is not possible, the technician will issue a Returned Material Authorization Number (RMA#).
c. If the unit is under warranty, the repairs are free.
d. Service procedures and returns may vary . internationally Refer to the APC by Schneider Electric
Web site for country specific instructions.
2 phone If this is not successful and the unit is still under. Prepare to troubleshoot the problem over the . ,
, warranty the SEIT Technical Support Representative will provide all necessary information to return the
unit for replacement .
5LED Condition
On Off On-line - The Back-UPS is supplying AC power to
the connected equipment
Constant Tone On Line Overload - The power being used by the
connected equipment has exceeded the capacity of the
unit. Disconnect some equipment.
Constant beeping Over-temperature Warning - The unit is
overheating and will shut down if the temperature is
not lowered. Disconnect some of the connected
equipment.
On
(Off during 4 beeps)
4 beeps repeated
every 30 seconds
On-Battery - The Back-UPS is supplying battery
power.
Flashing Rapid Beeping
(every 1/2 second)
Low Battery Warning - The Back-UPS has 2
minutes of runtime remaining.
Constant tone Bad Battery Detected - The battery needs to be
charged, or is at end of life. (See Battery
Replacement.)
Off Short eep very b e
4 seconds Low Battery Shutdown - During On Battery
operation the battery power was almost completely
exhausted, and the Back-UPS is waiting for AC power
to return to normal.
Constant Tone On Battery Overload - The connected equipment
requires more wer thanpo provided by the Back-UPS
battery. Unplug devices one at a time to remove
overload. If the problem is not corrected, contact SEIT
Technical Support
Constant Tone Charger Fault - Back-UPS has an internal problem,
and is no longer powering the load. Contact SEIT
Technical Support
Audible Alarm
Long beep every
4 seconds UPS has ov erheated and has shut down.
Unp lug connected devices one at a time or
wait for a few hours for system to co ol down.
Over-temperature Protected - The Back-
Status Indicators
Warranty
Register your product on-line. http://warranty.apc.com
The standard warranty is two (2) years from the date of purchase. SEIT standard procedure is to replace the
original unit with a factory reconditioned unit. Customers who must have the original unit back due to the
assignment of asset tags and set depreciation schedules must declare such a need at first contact with an SEIT
Technical Support representative. SEIT will ship the replacement unit once the defective unit has been
received by the repair department, or cross-ship upon the receipt of a valid credit card number. The customer
pays for shipping the unit to SEIT. SEIT ays groundp freight transportation costs to placement unit ship the re
to the customer.
No-load Shutdown
If the UPS is operating on battery power and detects that the connected equipment is using less than
15W of energ y for more than 15 minutes, it will shut do wn to conserve en ergy. When th e UPS is
reconnected to AC power, th e UPS will automatically switch on .
Operational Features
6
Automatic Voltage Regulation bo osts/trims th e AC voltage when it drop s/exceeds safe levels.
This allows the equipmen t plu gged in to th e unit to operate durin g low/h igh voltage co nditions,
conserving the battery power in the event of a power cut.
The Back-UP S will switch to battery power if the input voltag e level becomes too low/high for the
Automatic Voltage Regulation to comp ensate, or if the AC po wer is distorted.
Automatic Voltage Regulation (AVR)
Fuse Replacement
A spare fuse is provided in every Back-UP S unit.
Once the input current exceed s 5A, the installed
fuse in ev ery unit will burn to safeguard connected
equipment fro m excessive input currents. Replace
it using the sp are fuse, or with a fuse that has
similar input current rating.
Produktspecifikationer
Varumärke: | Apc |
Kategori: | UPS |
Modell: | Back-UPS BX650LI |
Behöver du hjälp?
Om du behöver hjälp med Apc Back-UPS BX650LI ställ en fråga nedan och andra användare kommer att svara dig
UPS Apc Manualer
18 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
13 Oktober 2024
4 Oktober 2024
UPS Manualer
- UPS AEG
- UPS IKEA
- UPS HP
- UPS Siemens
- UPS LC-Power
- UPS Tripp Lite
- UPS Energenie
- UPS Voltcraft
- UPS Emerson
- UPS Adj
- UPS Digitus
- UPS LevelOne
- UPS Eaton
- UPS Jung
- UPS CyberPower
- UPS Block
- UPS Avocent
- UPS Minuteman
- UPS Maruson
- UPS V7
- UPS Salicru
- UPS Equip
- UPS Approx
- UPS SurgeX
- UPS Murr Elektronik
- UPS Altronix
- UPS Ditek
- UPS Bxterra
- UPS Middle Atlantic
- UPS FSP
- UPS Atlantis Land
- UPS PowerWalker
- UPS FSP/Fortron
- UPS Online USV
Nyaste UPS Manualer
24 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
20 Oktober 2024
18 Oktober 2024
11 Oktober 2024
9 Oktober 2024
9 Oktober 2024
6 Oktober 2024