hank you for acquiring the Aqua View 45o Finder from Aquatica (# 20059), the viewnder optics are made from high quality coated glass elements
and as such should be treated with the same respect as your camera lenses or any precision optical tool; the viewnder external casing is machined from
aircraft quality aluminium and anodized for protection again salt water corrosion.
Your Aqua View 45o Finder is supplied with the following : One Soft carrying pouch and a protective cap.
Following are simple steps for the installation of your Aqua View 45o Finder:
First: If your housing has a regular eyepiece installed already, it must be removed, remove the back of your housing and place on a clean and dry sur-
face, on the inside locate the eye piece collar, and you should notice a rubber O-ring protruding from it. Remove the O-ring with either an O-ring tool or
a dull pointed object, making sure not to cut it. Once the O-ring is removed, push the eyepiece out by pressing on it with both thumbs from the inside.
Remove the Retaining O-ring from the collar, ip the housing back cover so that you are facing the external part of it, inspect and apply a light coat of
lubricant on the wall of the viewnder sealing surface of the housing making sure it is clear of debris, inspect carefully the two remaining O-ring from
the Aqua View Finder to insure they are clean and lubricate them, remember that a light coat is all that is needed, the O-ring does the sealing, not the
lubricant. The user as the responsibility to make sure that all O-rings as well as the viewnder are cleaned and properly installed.
Insert the Aqua View Finder by slightly rotating left and right. You will notice a small stainless steel alignment pin, there is a matched cut-out on the
external collar of the Aqua View Finder, this pin should come to rest in that cut-out.
Finally ip the housing back cover over and reinstall the retaining
O-ring on the Aqua View Finder internal collar. As always is the case when installing
components such as ports, extension and viewnder, the user should immerse the housing with out the camera to conrm that all was done properly
Warning: When traveling always remove the eyepiece from the housing and never lift or carry the housing using the Aqua View Finder
as a handle. It is your responsibility to advice people handling your equipment accordingly. Treat your eyepiece with care and store in a
padded container or lens bag.
Eye piece adjustment : It is possible to adjust The Aqua View Finder to one’s eyesight, to adjust use the eyesight adjustment of your camera
and rotate or slide until properly adjusted comfortably to your eye, to do this refer to the camera user manual, remember to use small incre-
ments.
When shooting vertical composed image with the housing, the viewnder can be rotated to either side to make viewing and composing
easier, to do so simply grab the body of the viewnder and rotate it either clockwise or counterclockwise depending of your shooting prefer-
rence
1: Retaining O-ring
2: Allignement pin slot
3: Sealing O-rings (x2)
4: View nder eye piece
AQUATICA
3025 De Baene St., Montreal, Quebec, Canada, H4S 1K8
Tel.: 514-737-9481 info@aquatica.ca Fax : 514-737-7685
The Aqua View has no user serviceable internal part, dismantling or tampering your
Aqua View Finder will void its warranty and may cause irreparable damages and/or
ooding of the unit and its housing.
------------WARNING------------
45
2
34
1