Ashland SW50 Bruksanvisning

Läs nedan 📖 manual på svenska för Ashland SW50 (51 sidor) i kategorin Vattenpump. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/51
Thank you for purchasing this pump. Take the time to read the instruc
tions carefully before using this product. We strongly recommend that
you keep this instruction manual in a safe place for future reference.
Please refer to our website and the Products Center for additional
installation and operation instructions and replacement parts information.
Danger indicates an
imminent hazardous situation
which, if not avoided, WILL result in death or
serious injury.
Caution indicates a
potentially hazardous situation
which, if not avoided, MAY result in minor or
moderate injury.
MARKS AND MEANING:
LIMITED WARRANTY
WARNING
CAUTION
DANGER
Warning indicates an
imminent hazardous situation
which, if not avoided, MAY result in death or
serious injury.
OPERATION, PERFORMANCE,
SPECIFICATIONS and PARTS MANUAL
SWH50/SWH100/SWH150/
SWH200 & SWHD100/
SWHD150/SWHD200
Heavy Duty
Sewage Pumps SWHD100/SWHD150/SWHD200
SWH50/SWH100/SWH150/SWH200
IMPORTANT
Prior to installation, record Model Number,
MFG Date, Amps, Voltage, Phase and HP,
from pump nameplate for future reference.
Also record the voltage and current readings
at startup:
Model Number:
MFG Date:
Phase:
HP:
SN:
1 Phase Models
Amps: Volts:
3 Phase Models
Amps L1-2: Volts L1-2:
Amps L2-3: Volts L2-3:
Amps L3-1 Volts L3-1:
2
DANGER
Before installation, read the following instructions care-
fully. Failure to follow instruction and safety information
could cause serious bodily injury, death and/or property
damage. Each Ashland Pump is individually factory tested
to ensure proper performance. Closely following these
instructions will eliminate potential operating problems
assuring years of trouble-free service.
Most accidents can be avoided by using common sense.
IMPORTANT - Ashland Pump is not responsible for
losses, injury or death resulting from failure to observe
these safety precautions, misuse, abuse or misapplica-
tion of pumps or equipment.
All returned products must
be cleaned, sanitized, or
decontaminated prior to shipment, to
insure employees will not be exposed to
health hazards in handling said materials.
All applicable laws and regulations shall apply.
Bronze/brass fitted pumps may
contain lead levels higher than con-
sidered safe for potable water systems. Government
agencies have determined that leaded copper alloys
should not be used in potable water applications.
Installation, wiring, and junction
connections must be in accord-
ance with the National Electric Code and all applicable
state and local codes. Requirements may vary depend-
ing on usage and location.
Installation and servicing is to be
conducted by qualified personnel only.
Rotating machinery, amputation
or severe lacerations can result.
Keep clear of suction and discharge
openings. DO NOT insert fingers into pump
with power connected.
Always wear eye protection when
working on pumps. Do not wear loose
clothing that may become entangled in moving parts.
Pumps build up heat and
pressure during operation.
Allow time for pumps to cool before handling or ser-
vicing.
Hazardous Voltage can shock,
burn or cause death. This pump is
not intended for use in swimming pools or
water installations where human contact with
pumped fluid is possible.
Risk of electrical shock. To
reduce risk of electrical shock,
always disconnect pump from source
before handling. Lock out power & tag.
Sewage Pumps
Model: SWH & SWHD Series
General Safety Information
WARNING
Do Not use these pumps in water
over 104°F. Do not exceed manu-
factures recommended maximum performance, as this
could cause the motor to overheat.
WARNING
WARNING
WARNING
WARNING
DANGER
DANGER
DANGER
These pumps are NOT to be
installed in locations classified
as hazardous in accordance with the
National Electric Code, ANSI/NFPA 70.
WARNING
Sump and sewage pumps often
handle materials which could cause
illness or disease. Wear adequate protective clothing
when working on a used pump or piping. Never enter
a basin after it has been used.
WARNING
Do not introduce into any sewer,
either directly, or through a kitchen
waste disposal unit or toilet: Seafood Shells, Aquarium
Gravel, Cat Litter, Plastic Objects, Sanitary Napkins or
Tampons, Diapers, Rags, Disposable Wipes or Cloth,
Medications, Flammable Material, Oil or Grease,
Strong Chemicals, Gasoline.
DANGER
DANGER
Do not lift, carry or hang pump by
the electrical cables. Damage to
the electrical cables can cause shock, burns or
death. Never handle connected power cords
with wet hands. Use appropriate lifting device.
DANGER
Failure to permanently ground the
pump, motor and controls before
connecting to power can cause shock, burns
or death.
DANGER
Make sure lifting handles are securely
fastened each time before lifting.
CAUTION
Operation against a closed discharge valve will cause
premature bearing and seal failure on any pump.
Any wiring of pumps should be performed by a
qualified electrician.
Cable should be protected at all times to avoid
punctures, cuts, bruises, and abrasions-inspect
frequently.
Never handle connected power cords with wet hands.
Never let cords or plugs lie in water outside the sump
pit.
These pumps are offered in a three phase and single
phase wiring configuration. Voltages will vary
according to the application and can be seen in the
tables in this manual.
3
Sewage Pumps
Model: SWH & SWHD Series
Specications
Note: All dimensions have a tolerance of + 1/8”
Model HP Hz Volts/Ph RPM Full Load Nema Start Cord Cord Cord
Amps Code Type Size O.D. Volute Housing Impeller Shaft
SWH50M1-20 1/2 60 115/1 3450 12.0 P SOW 16AWG/3C .430 Cast Iron Cast Iron Cast Iron SS
SWH50M2-20 1/2 60 230/1 3450 6.0 P SOW 16AWG/3C .430 Cast Iron Cast Iron Cast Iron SS
SWH50M3-20 1/2 60 230/3 3450 4 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH50M4-20 1/2 60 460/3 3450 2 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH50M5-20 1/2 60 208/1 3450 6.8 P SOW 16AWG/3C .430 Cast Iron Cast Iron Cast Iron SS
SWH50M6-20 1/2 60 208/3 3450 4.2 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH100M2-20 1 60 230/1 3450 11 P SOW 16AWG/3C .430 Cast Iron Cast Iron Cast Iron SS
SWH100M3-20 1 60 230/3 3450 6.6 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH100M4-20 1 60 460/3 3450 3.3 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH100M5-20 1 60 208/1 3450 12 P SOW 16AWG/3C .430 Cast Iron Cast Iron Cast Iron SS
SWH100M6-20 1 60 208/3 3450 6.8 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH150M2-20 1-1/2 60 230/1 3450 13.8 P SOW 14AWG/3C .575 Cast Iron Cast Iron Cast Iron SS
SWH150M3-20 1-1/2 60 230/3 3450 7.6 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH150M4-20 1-1/2 60 460/3 3450 3.8 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH150M5-20 1-1/2 60 208/1 3450 15 P SOW 14AWG/3C .575 Cast Iron Cast Iron Cast Iron SS
SWH150M6-20 1-1/2 60 208/3 3450 7.8 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH200M2-20 2 60 230/1 3450 18 L SOW 14AWG/3C .575 Cast Iron Cast Iron Cast Iron SS
SWH200M3-20 2 60 230/3 3450 9 L SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH200M4-20 2 60 460/3 3450 4.5 L SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWH200M5-20 2 60 208/1 3450 20 L SOW 12AWG/3C .655 Cast Iron Cast Iron Cast Iron SS
SWH200M6-20 2 60 208/3 3450 10.4 L SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD100M2-20 1 60 230/1 3450 11 P SOW 16AWG/3C .430 Cast Iron Cast Iron Cast Iron SS
SWHD100M3-20 1 60 230/3 3450 6.6 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD100M4-20 1 60 460/3 3450 3.3 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD100M5-20 1 60 208/1 3450 12 P SOW 16AWG/3C .430 Cast Iron Cast Iron Cast Iron SS
SWHD100M6-20 1 60 208/3 3450 6.8 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD150M2-20 1-1/2 60 230/1 3450 13.8 P SOW 14AWG/3C .575 Cast Iron Cast Iron Cast Iron SS
SWHD150M3-20 1-1/2 60 230/3 3450 7.6 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD150M4-20 1-1/2 60 460/3 3450 3.8 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD150M5-20 1-1/2 60 208/1 3450 15 P SOW 14AWG/3C .575 Cast Iron Cast Iron Cast Iron SS
SWHD150M6-20 1-1/2 60 208/3 3450 7.8 P SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD200M2-20 2 60 230/1 3450 18 L SOW 14AWG/3C .575 Cast Iron Cast Iron Cast Iron SS
SWHD200M3-20 2 60 230/3 3450 9 L SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD200M4-20 2 60 460/3 3450 4.5 L SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS
SWHD200M5-20 2 60 208/1 3450 20 L SOW 12AWG/3C .655 Cast Iron Cast Iron Cast Iron SS
SWHD200M6-20 2 60 208/3 3450 10.4 L SOW 16AWG/4C .460 Cast Iron Cast Iron Cast Iron SS

Produktspecifikationer

Varumärke: Ashland
Kategori: Vattenpump
Modell: SW50

Behöver du hjälp?

Om du behöver hjälp med Ashland SW50 ställ en fråga nedan och andra användare kommer att svara dig




Vattenpump Ashland Manualer

Ashland

Ashland SPV50 Bruksanvisning

11 September 2024
Ashland

Ashland EP45 Bruksanvisning

11 September 2024
Ashland

Ashland SPV33 Bruksanvisning

11 September 2024
Ashland

Ashland SW50 Bruksanvisning

11 September 2024
Ashland

Ashland UT56 Bruksanvisning

11 September 2024

Vattenpump Manualer

Nyaste Vattenpump Manualer