BEA LZR-H110 Bruksanvisning
BEA
Rörelsedetektor
LZR-H110
Läs nedan 📖 manual på svenska för BEA LZR-H110 (12 sidor) i kategorin Rörelsedetektor. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/12
75.5897.02 LZR-H110 20170821 Page 1 of 12
EN
75.5897.02 LZR-H110 20170821 Page 1 of 12
Page 2 of 12 75.5897.02 LZR-H110 20170821
The device contains IR and visible laser diodes.
IR laser: wavelength 905nm; max. output pulse power 75W
(Class 1 according to IEC 60825-1)
Visible laser: wavelength 650nm; max. output CW power 3mW
(Class 3R according to IEC 60825-1)
The visible laser beams are inactive during normal functioning.
The installer can activate the visible lasers if needed.
CAUTION!
Use of controls, adjustments, or performance of procedures other than those specified herein
may result in hazardous radiation exposure.
INSTALLATION AND MAINTENANCE
Avoid extreme
vibrations.
Do not cover
the front screens.
Avoid moving objects
and light sources in
the detection field.
Avoid condensation.
Avoid the presence
of smoke and fog in
the detection field.
Avoid exposure to
sudden and extreme
temperature changes.
Keep the sensor
permanently powered
in environments where
the temperature can
descend below 0°C.
Wipe the front
screens regularly
with a clean and
damp cloth.
Do not use aggressive
products to clean
the front screens.
Avoid direct exposure
to high pressure
cleaning.
Do not look into the laser
emitter or the visible red
laser beams.
The warranty is void if
unauthorized repairs are
made or attempted by
unauthorized personnel.
Only trained and qualified
personnel are recommended
to install and set up the
sensor.
After installation, enter an
access code by remote
control.
This sensor is designed to be used as a movement and presence detector to initiate the opening and the closing
process of a gate or a barrier. Other use of the device, especially on industrial doors, is outside the permitted purpose
and cannot be guaranteed by the manufacturer and might infringe the following patent application EP 1 470 314 B1.
The manufacturer of the system is responsible for installing the sensor and the system in compliance with applicable
national and international regulations and standards on safety and if applicable, the machinery directive 2006/42/EC.
The manufacturer of the sensor cannot be held responsible for incorrect installations or inappropriate adjustments of
the sensor.
SAFETY
Page 2 of 12 75.5897.02 LZR-H110 20170821
75.5897.02 LZR-H110 20170821 Page 3 of 12
1
2
3
4
5
6
8
9
7
1 2 3 4
DESCRIPTION
SYMBOLS
LED SIGNAL
DETECTION LEDs
no detection
ERROR LED POWER LED
detection
no error
error
no power
power
Caution!
Laser radiation
LED flashes quickly
LED flashes
LED is off
1. laser sweep emission
2. laser sweep reception
3. LED signal (4)
4. screw for position lock (2)
5. connector
6. protection cover
7. visible laser beam (3)
8. notch for tilt angle adjustment (2)
9. adjustable bracket
1. Detection LED: relay 1 – opening field
2. Detection LED: relay 2 – safety field
3. Error LED
4. Power LED
Remote control
sequence
Possible remote control
adjustments
Factory values
LED flashes slowly
All 4 LEDs can be switched off and on again by remote control.
This can be useful in cases where the sensor should not draw any attention.
Important Tip Quick
installation
75.5897.02 LZR-H110 20170821 Page 3 of 12
Produktspecifikationer
Varumärke: | BEA |
Kategori: | Rörelsedetektor |
Modell: | LZR-H110 |
Behöver du hjälp?
Om du behöver hjälp med BEA LZR-H110 ställ en fråga nedan och andra användare kommer att svara dig
Rörelsedetektor BEA Manualer
12 September 2024
Rörelsedetektor Manualer
- Rörelsedetektor Honeywell
- Rörelsedetektor Abus
- Rörelsedetektor Alecto
- Rörelsedetektor Hikvision
- Rörelsedetektor Nedis
- Rörelsedetektor Yale
- Rörelsedetektor Optex
- Rörelsedetektor Schneider
- Rörelsedetektor Theben
- Rörelsedetektor Velleman
- Rörelsedetektor Vemer
- Rörelsedetektor Smartwares
- Rörelsedetektor Steren
- Rörelsedetektor Perel
- Rörelsedetektor Steinel
- Rörelsedetektor ESYLUX
- Rörelsedetektor Devolo
- Rörelsedetektor Dahua Technology
- Rörelsedetektor Cotech
- Rörelsedetektor Grothe
- Rörelsedetektor Merten
- Rörelsedetektor Goobay
- Rörelsedetektor Hager
- Rörelsedetektor Massive
- Rörelsedetektor Konig
- Rörelsedetektor Busch-Jaeger
- Rörelsedetektor Swann
- Rörelsedetektor DESQ
- Rörelsedetektor Xavax
- Rörelsedetektor Marmitek
- Rörelsedetektor Orbis
- Rörelsedetektor Jung
- Rörelsedetektor DSC
- Rörelsedetektor HQ
- Rörelsedetektor Iget
- Rörelsedetektor Nexa
- Rörelsedetektor Satel
- Rörelsedetektor Wentronic
- Rörelsedetektor Homematic IP
- Rörelsedetektor Vernier
- Rörelsedetektor Chuango
- Rörelsedetektor ORNO
- Rörelsedetektor Berker
- Rörelsedetektor Extron
- Rörelsedetektor Maxsa
- Rörelsedetektor Kopp
- Rörelsedetektor Vimar
- Rörelsedetektor Kogan
- Rörelsedetektor XQ-Lite
- Rörelsedetektor Brinno
- Rörelsedetektor Legrand
- Rörelsedetektor Elgato
- Rörelsedetektor Intertechno
- Rörelsedetektor Schwaiger
- Rörelsedetektor Inovonics
- Rörelsedetektor V-Tac
- Rörelsedetektor Bitron
- Rörelsedetektor Suevia
- Rörelsedetektor Pentatech
- Rörelsedetektor Joy-it
- Rörelsedetektor Tellur
- Rörelsedetektor Megatron
- Rörelsedetektor Ledvance
- Rörelsedetektor Gewiss
- Rörelsedetektor ALC
- Rörelsedetektor Avigilon
- Rörelsedetektor GEV
- Rörelsedetektor Pepperl+Fuchs
Nyaste Rörelsedetektor Manualer
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024