Blonder Tongue BIDA 550-30 Bruksanvisning

Blonder Tongue Radio BIDA 550-30

Läs nedan 📖 manual på svenska för Blonder Tongue BIDA 550-30 (8 sidor) i kategorin Radio. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/8
Description
The Blonder Tongue BIDA is a completely self-contained broadband indoor distribution amplifier designed specifically
for CATV and SMATV signal distribution systems which use a cable drop as a signal source. Three models are
available; the #5400-73 with a 47 to 750 MHz bandpass and the #5400-53 and -55 with 47 to 550 MHz bandpass. The
basic amplifier is configured for one-way operation. Optional field installable modules provide two-way capability with
either a passive or active sub-channel return path.
The #5400-55 has a flat operating gain of approximately 50 dB. The #5400-53, and -73 have a gain of about 33 dB
(see Specifications for typical values of each model). Lower operating gains can be achieved by adjusting the variable
attenuator. All models can be attenuated over a range of 15 dB. Gain and slope controls are located on the front
panel for easy set-up and adjustment. Two -30 dB backmatched test points are provided to permit testing without
interruption of service.
In applications where input signals are too high or where greater cable equalization is necessary, the BIDA can be
reconfigured by using plug-in attenuators and cable slope equalizers to meet particular requirements.
Push-pull, hybrid IC modules enable the BIDA to operate at high output levels while retaining low distortion
characteristics.
The aluminum chassis is designed to provide excellent heat dissipation thus allowing operation at high ambient
temperatures with no degradation of performance or reliability.
Features
Externally Accessible Test Points Permit In-Service
Testing.
Aluminum Chassis Designed for Superior Heat
Dissipation to Insure Component Reliability.
Exceeds FCC Specs for Both Conducted and Radiated
Interference @ Full Output Level.
External Fuse for Ease of Replacement.
LED Pilot Light.
Line Transient Protection.
Hybrid IC Circuitry for High Output with Low
Distortion.
Exceptional Temperature Stability Range of -2 C to
+60° C.
Designed for Critical Applications Requiring High Gain.
Front Panel Gain and Slope Controls for Easy
Adjustments.
Field Installable Options provide Two-Way Capability
(Passive or Active).
INSTRUCTION MANUAL
One Jake Brown Road
Old Bridge, NJ 08857-1000 USA
(800) 523-6049 (732) 679-4000 • FAX: (732) 679-4353
www.blondertongue.com
©2009 Blonder Tongue Laboratories, Inc. All rights reserved. Specifications are subject to change without notice. Trademarks are the property of their respective owner.
651166900P
BIDA Series
Broadband Indoor Distribution Amplifiers
Model Stock No.
BIDA 550-30
5400-53
BIDA 750-30
5400-73
BIDA 550-50 5400-55
2BIDA Series
Instruction Manual
RF
IN
-30 dB
RETURN
FILTER
OPTION
BIDA-RF
5407
ATTEN-
UATOR
OPTION
BIDA-FA
5411
EQUALIZER
OPTION
BIDA-CE
547X
AMP
GAIN
CONTROL
FULL
SLOPE
CONTROL
FLAT
AMP
RETURN
FILTER
OPTION
BIDA-RF
5407
RF
OUT
-30 dBPASSIVE RETURN PATH
RETURN
AMPLIFIER
OPTION
BIDA-RA
5402
ACTIVE RETURN PATH
Block Diagram
Returning Product for Repair or Credit
A Return Material Authorization (RMA) Number is required on all products returned to
Blonder Tongue, regardless if the product is being returned for repair or credit. Before
returning product, please contact the Blonder Tongue Service Department at 1-800-523-6049, Ext. 4256
or visit our website: www.blondertongue.com for further information.
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT EXPOSE THIS UNIT TO RAIN OR MOISTURE
NOTE TO CATV SYSTEM INSTALLER
This reminder is provided to call the CATV System Installer’s attention to Article 820-40 of the NEC that
provides guidelines for proper grounding and, in particular, specifies that the cable ground shall be
connected to the grounding system of the building, as close to the point of cable entry as practical.
For all pluggable equipment the socket-outlet shall be
installed near the equipment and shall be easily accessible.
TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER FROM THIS UNIT.
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
!
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrow-
head symbol within an equilateral
triangle is intended to alert you
to the presence of uninsulated
“dangerous voltage” within the
product’s enclosure that may be
of sufficient magnitude to consti-
tute a risk of electrical shock to
persons.
The exclamation point within an
equilateral triangle is intended
to alert you to the presence of
important operating and main-
tenance (servicing) instructions
in the literature accompanying
the product.
3
BIDA Series
Instruction Manual
Safety Instructions
Read all safety and operating instructions before you operate the unit.
Retain all safety and operating instructions for future reference.
Heed all warnings on the unit and in the safety and operating instructions.
Follow all installation, operating, and use instructions.
Unplug the unit from the AC power outlet before cleaning. Use only a damp cloth for cleaning the exterior of the unit.
Do not use accessories or attachments not recommended by Blonder Tongue, as they may cause hazards, and will void
the warranty.
Do not operate the unit in high-humidity areas, or expose it to water or moisture.
Do not block or cover slots and openings in the unit. These are provided for ventilation and protection from overheating.
Never place the unit near or over a radiator or heat register. Do not place the unit in an enclosure such as a cabinet with-
out proper ventilation. Do not mount equipment in the rack space directly above or below the unit.
You should always follow these instructions to help ensure against injury to
yourself and damage to your equipment.
Operate the unit using only the type of power source indicated on the marking label. Unplug the unit power cord by
gripping the plug, not the cord.
The unit is equipped with a three-wire ground-type plug. This plug will fit only into a ground-type power outlet. If you
are unable to insert the plug into the outlet, contact an electrician to replace the outlet. Do not defeat the safety purpose
of the ground-type plug.
Route power supply cords so that they are not likely to be walked on or pinched by items placed upon or against them.
Pay particular attention to cords at plugs, convenience receptacles, and the point where they exit from the unit.
Be sure that the outdoor components of the antenna system are grounded in accordance with local, federal, and National
Electrical Code (NEC) requirements. Pay special attention to NEC Sections 810 and 820. See the example shown in the
following diagram:

Produktspecifikationer

Varumärke: Blonder Tongue
Kategori: Radio
Modell: BIDA 550-30

Behöver du hjälp?

Om du behöver hjälp med Blonder Tongue BIDA 550-30 ställ en fråga nedan och andra användare kommer att svara dig




Radio Blonder Tongue Manualer

Radio Manualer

Nyaste Radio Manualer