Bobrick QuietDry B-778 Bruksanvisning

Bobrick Handendroger QuietDry B-778

Läs nedan 📖 manual på svenska för Bobrick QuietDry B-778 (17 sidor) i kategorin Handendroger. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/17
Form No. 700-69 Multi Language (Rev. 7/1/13) © 2013 Bobrick Washroom Equipment, Inc. Printed in U.S.A.
INSTALLATION INSTRUCTIONS
B-700, B-708, B-770 & B-778
SURFACE-MOUNTED
AUTOMATIC HAND DRYER
Installation Instructions Surface-Mounted Hand Dryer Pages 2 & 3 ...............................................
Instrucciones De Instalación Secadores De Manos Bobrick
Montados Sobre La Pared Tipo Pages 4 & 5 ......................................................................................
Einbauanleitung Bobrick -Hände
Für Aufputzmontage Pages 6 & 7 ......................................................................................................
Notice D’Installation Sèche-Mains Bobrick
Montés En Surface Pages 8 & 9 ..........................................................................................................
Istruzioni Per L’installazione Asciugamani Bobrick Pages 10 & 11 ................................................
表面安装式自动感应干手机/干发机安装说明书 ................................................Pages 12 & 13
Warranties Pages 14 & 15 ...................................................................................................................
1
WARNING: TURN ELECTRICAL POWER SUPPLY OFF
BEFORE MAKING ELECTRICAL CONNECTIONS. DRYER
MUST BE GROUNDED (EARTHED).
Finish Face of Floor
10-15/64''
260mm
SS
33/64''
13mm
7-43/64''
195mm
Dimension
A
1-7/64''
28mm
S
9-7/16''
240mm
5/16''
8mm
3/4''
19mm
15/32''
12mm
10-3/
265m
8-43/64''
220mm
3/16''
5mm
3/4''
19mm
6-1/16''
155mm
S
1''
25mm
1-3/8''
35mm
Flange Cutout for
Surface Wiring
7/8''
22mm
Dia. Hole for
Between Wall Wiring
BOBRICK
BOBRICK
Form No. 700-69 Multi Language (Rev. 7/1/13) © 2013 Bobrick Washroom Equipment, Inc. Printed in U.S.A.
Electrical Characteristics
Recommended Mounting Heights
Removal of Cover
Installation of Mounting Base
Important
2
Hand dryer models B-700, B-708, 115V AC, 20 Amp, 50/60 Hz, Single Phase, cULus listed;
Hand dryer models B-700, B-708, 208-240V AC, 9-10 Amp, 50/60 Hz, Single Phase, cULus listed, VDE approved, CE marked.
Hand dryer models B-770, B-778, 115V AC, 12 Amp, 50/60 Hz, Single Phase, cULus listed;
Hand dryer models B-770, B-778 208-240V AC, 5.5-6.3 Amp, 50/60 Hz, Single Phase; cULus listed, VDE approved, CE marked.
Distance from floor to bottom mounting screw holes of mounting base. (Dimension A)
1. Start installation of dryer by
removing cover. To loosen
two cover bolts, insert Allen
Wrench (provided with dryer)
into holes located on bottom
of cover on each side of air
intake grille. Make sure
wrench fits into head
of cover bolts and turn
CLOCKWISE until bolts stop
turning. When cover bolts
are screwed in all the way,
cover can be removed.
2. To remove cover, place a
hand on each side of cover
and push up toward top
of dryer releasing cover
from studs at top of
mounting base. Lift cover
off mounting base by
pulling forward at the
bottom and upward at the
same time.
Hand Dryer
* Bobrick automatic hand dryers should be installed 15" (380mm) above any projection or horizontal surface which may interfere with
the operation of the automatic sensor.
1. Hold the Installation Template against the wall in the desired
location of the installed dryer. See recommended mounting
heights above.
2. Make sure line on template representing bottom of dryer
mounting base is horizontal and located at the desired height
above floor.
NOTE: Surface-mounted electrical supply entry is located in the
lower right corner of the mounting base. Surface-mounted supply
cable should be fitted in a conduit.
3. Drill four holes for 1/4" (6.4mm) diameter mounting bolts or
screws (not furnished by Bobrick).
4. Fasten mounting base securely to wall.
Men's Washrooms .............................................................................................................................................................46'' (117cm)
Women's Washrooms ........................................................................................................................................................44'' (112cm)
Children's Washrooms, ages 3-9 32'' (81cm) ......................................................................................................................................
Children's Washrooms, ages 9-12 36'' (91cm) .....................................................................................................................................
Children's Washrooms, ages 12-15 40'' (102cm) ...................................................................................................................................
Children's Washrooms, ages 15-18 44'' (112cm) ...................................................................................................................................
For the Handicapped 38'' (97cm) .........................................................................................................................................................
* Warm air hand dryer. Intended for use in a household environment by non-expert users. Not suitable for outdoor use.
** This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or
mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning
use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
*** If a fault develops disconnect the electrical supply, a qualified electrician should be called.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL
BUILDING CODE. UNIT MUST BE INSTALLED BY
A QUALIFIED LICENSED ELECTRICIAN
BOBRICK
BOBRICK
BOBRICK
Form No. 700-69 Multi Language (Rev. 7/1/13) © 2013 Bobrick Washroom Equipment, Inc. Printed in U.S.A.
Electrical Connection
Check Dryer Operation
Maintenance
Replace Cover
3
1. Replace cover by positioning
top of cover on studs on top
of mounting base and tipping
bottom of cover toward wall.
Push bottom of cover firmly
against wall.
NOTE: Space between cover
and wall must be the same on
four sides.
2. To tighten two cover bolts,
insert Allen wrench into
holes on bottom of cover.
Make sure wrench fits into
head of cover bolts and
turn COUNTERCLOCKWISE
until bolts are tightened.
NOTE: Do not overtighten cover
bolts; overtightening cover bolts
may damage enamel finish.
1. For TouchButton Hand and Hair Dryers: Turn electrical power supply on. Touch the
chrome-plated touchbutton once and dryer should turn on. Touch the touchbutton again after
a few seconds and dryer should stop. If left on, Hand Dryers will shut off automatically after 30
seconds; Hair Dryers will shut off after 80 seconds.
2. For AutoPilot Hand Dryers: Turn electrical power supply on. Position hands under nozzle and
dryer should turn on. Remove hands from under nozzle and dryer should stop.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED
LICENSED ELECTRICIAN
1. Connect dryer to nearest distribution panel. Use wire as required by local electrical code. In the United States and Canada use
No. 12 wire or larger.
2. Wiring Instructions:
a. This appliance is intended for connection to fixed wiring.
b. A fused means for disconnection in all poles must be provided in the fixed wiring in accordance with the wiring rules.
c. Check that the electrical rating shown on the Hand Dryer (rating label) is compatible with the electrical supply.
d. WARNING: THIS PRODUCT MUST BE EARTHED.
e. Installation and wiring must conform to current IEE Regulations (UK), local or appropriate regulation (other countries).
f. For 115 Volt Dryers: Connect ground/earth supply the terminal marked , the Live supply to terminal marked L and neutral
supply to terminal marked N. A DEDICATED LINE IS REQUIRED FOR EACH 115 VOLT DRYER.
For 208–240 Volt Dryers: g. Connect ground/earth supply the terminal marked and the 208-240 Volt wires to terminals
marked .L (L1) N (L2) and
3. Secure electrical wire in strain relief clamp provided on mounting base.
WARNING: MOTOR LAMINATIONS ARE LIVE. TURN ELECTRICAL POWER SUPPLY OFF BEFORE DOING ANY
MAINTENANCE OR SERVICE TO DRYER. DRYER MUST NOT BE OPERATED UNLESS COVER IS IN PLACE.
FOR PROPER ELECTRICAL CONNECTIONS, CHECK LOCAL BUILDING CODE. UNIT MUST BE INSTALLED BY A QUALIFIED
LICENSED ELECTRICIAN
1. Exterior of cover should be cleaned with a damp cloth to remove dust and surface dirt. Do not use abrasive agents or solvents as
they may
permanently damage surface of cover.
2. At least once every 6 months remove cover. Using a small brush or vacuum, clean out buildup of dust and lint from air-intake grille
and baffle.
NOTE: if dryer is installed where there is a lot of dust and dirt in the air, the interior of the dryer should be cleaned out more
frequently.

Produktspecifikationer

Varumärke: Bobrick
Kategori: Handendroger
Modell: QuietDry B-778

Behöver du hjälp?

Om du behöver hjälp med Bobrick QuietDry B-778 ställ en fråga nedan och andra användare kommer att svara dig