Installation instructions
Electric Heat Pump Water Heater
Compress 3000 DW FO
6720801244-00.1V
HP 270-1E 0 FOV/S...
6 720 801 244 (2013/08) AU
6 720 801 244 (2013/08) Compress 3000 DW FO
2 | Index
Index
1 Key to symbols and safety instructions . . . . . . . . . . . . . 3
1.1 Key to symbols . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Safety information . . . . . . . . . . . . . . . . . . . . . . . 3
2 Standard delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 Appliance details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.2 Features and safety devices . . . . . . . . . . . . . . . 7
3.3 Specification tables . . . . . . . . . . . . . . . . . . . . . . 9
3.4 Storing and transportation . . . . . . . . . . . . . . 10
3.4.1 Transport using a forklift . . . . . . . . . . . . . . . . 10
3.4.2 Manual transport . . . . . . . . . . . . . . . . . . . . . . 10
3.5 Operational principle (brief overview
of modes) . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
3.6 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.7 Clearances . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
4 Installation instructions . . . . . . . . . . . . . . . . . . . . . . . . 14
4.1 Tools required . . . . . . . . . . . . . . . . . . . . . . . . 15
4.2 Location requirements . . . . . . . . . . . . . . . . . 15
4.3 Secure the appliance . . . . . . . . . . . . . . . . . . . 16
4.4 Water piping . . . . . . . . . . . . . . . . . . . . . . . . . . 16
4.4.1 Inlet - Outlet connections . . . . . . . . . . . . . . . 16
4.4.2 Dielectric joint (not supplied with
the appliance) . . . . . . . . . . . . . . . . . . . . . . . . .17
4.4.3 Condensate Drain Tubes (not supplied with
the appliance) . . . . . . . . . . . . . . . . . . . . . . . . .17
4.4.4 TPR Valve (supplied with the appliance) . . . 17
4.4.5 Thermal expansion tank (not supplied with
the appliance) . . . . . . . . . . . . . . . . . . . . . . . . .18
4.4.6 Temperature mixing device (not supplied
with the appliance) . . . . . . . . . . . . . . . . . . . . . 18
4.4.7 Pressure limiting valve (not supplied with
the appliance) . . . . . . . . . . . . . . . . . . . . . . . . .18
4.4.8 Expansion control valve (not supplied with
the appliance) . . . . . . . . . . . . . . . . . . . . . . . . .18
4.5 Electric requirements . . . . . . . . . . . . . . . . . . 18
4.6 Installation configurations . . . . . . . . . . . . . . . 19
4.6.1 Ecological ambient heat recovery . . . . . . . . . 19
4.7 Insulation blanket . . . . . . . . . . . . . . . . . . . . . 20
4.8 Fill the water storage tank . . . . . . . . . . . . . . . 20
4.8.1 Water characteristics . . . . . . . . . . . . . . . . . . 21
4.9 Installation checklist . . . . . . . . . . . . . . . . . . . 21
4.10 What to expect for “normal startup” . . . . . . . 23
4.11 Off-peak compatibility . . . . . . . . . . . . . . . . . . 23
5 Operation Instructions . . . . . . . . . . . . . . . . . . . . . . . . . 24
5.1 Safety warnings . . . . . . . . . . . . . . . . . . . . . . . 24
5.2 Working display . . . . . . . . . . . . . . . . . . . . . . . 25
5.3 Working modes . . . . . . . . . . . . . . . . . . . . . . . 25
5.4 „Operating“ menu . . . . . . . . . . . . . . . . . . . . . . 25
5.4.1 „manual“ mode . . . . . . . . . . . . . . . . . . . . . . . . 25
5.4.2 „P1“, „P2“ and „P3“ modes . . . . . . . . . . . . . . 25
5.4.3 „Off“ mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
5.5 Temperature set point . . . . . . . . . . . . . . . . . . 26
5.6 „Main“ menu . . . . . . . . . . . . . . . . . . . . . . . . . . 26
5.6.1 „Mode“ function - heating modes . . . . . . . . . . 26
5.6.2 „Prog“ function - Timetable operation
programming . . . . . . . . . . . . . . . . . . . . . . . . . 27
5.6.3 Silent Mode programming - „Sil“ function . . . 29
5.6.4 „Leg“ function - automatic thermal
disinfection . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
5.6.5 „Set“ function - adjustments . . . . . . . . . . . . . 31
5.6.6 „Purg“ function - purge . . . . . . . . . . . . . . . . . . 31
5.6.7 „Info“ function - information . . . . . . . . . . . . . . 31
5.7 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . 32
5.8 Factory configurations . . . . . . . . . . . . . . . . . . 32
5.9 Selecting the temperature units - „°C“ or „ °F“ 32
5.10 Setting the time and day of the week . . . . . . . 33
5.11 Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
6 Maintenance and repair . . . . . . . . . . . . . . . . . . . . . . . . 35
6.1 Periodic Inspection . . . . . . . . . . . . . . . . . . . . . 35
6.2 Temperature and pressure relief valve
(PTR Valve) . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.3 Flushing tank . . . . . . . . . . . . . . . . . . . . . . . . . . 35
6.4 Draining the Water Heater . . . . . . . . . . . . . . . 35
6.5 Vacation and Extended Shutdown . . . . . . . . . 36
6.6 Clearing the Condensation Drain Tubes . . . . 36
6.7 Refrigerant circuit . . . . . . . . . . . . . . . . . . . . . . 36
6.8 Anode Rod servicing . . . . . . . . . . . . . . . . . . . . 36
6.9 Checking/replacing the magnesium anode . . 36
6.10 Service menu . . . . . . . . . . . . . . . . . . . . . . . . . . 37
7 Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.1 Fault display . . . . . . . . . . . . . . . . . . . . . . . . . . 40
7.2 Displays . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
8 Electrical diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
9 Environmental protection . . . . . . . . . . . . . . . . . . . . . . . 43
10 Warranty details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44
6 720 801 244 (2013/08)Compress 3000 DW FO
Key to symbols and safety instructions | 3
1 Key to symbols and safety
instructions
1.1 Key to symbols
Warnings
The following keywords are defined and can be used in this
document:
•NOTICE indicates a situation that could result in damage to
property or equipment.
•CAUTION indicates a situation that could result in minor to
medium injury.
•WARNING indicates a situation that could result in severe
injury or death.
•DANGER indicates a situation that will result in severe
injury or death.
Important information
Additional symbols
1.2 Safety information
„Water“ safety warnings
Warnings in this document are identified by a
warning triangle printed against a grey
background.
Keywords at the start of a warning indicate
the type and seriousness of the ensuing risk
if measures to prevent the risk are not taken.
This symbol indicates important information
where there is no risk to people or property.
Symbol Explanation
▶ Step in an action sequence
Cross-reference to another part of the document
• List entry
– List entry (second level)
Table 1
WARNING:
This water heater is not suitable for pool
heating.
WARNING:
The appliance should be located in an area
where leakage of the heater or connections
will not result in damage to the area adjacent
to the appliance or to lower floors of the
structure. When such locations cannot be
avoided, it is recommended that a suitable
drain pan, adequately drained, be installed
under the appliance.
WARNING:
If a water heater is installed in a closed water
supply system, such as one having a
backflow preventer in the cold water supply
line, means shall be provided to control
thermal expansion. Contact the water
supplier or local plumber on how to control
this situation.
WARNING:
Precautions must be taken prior to manually
operating the relief valve to avoid contact
with hot water coming out of the relief valve
and to prevent water damage.
WARNING:
If a relief valve discharges periodically, this
may be due to thermal expansion in a closed
water supply system. Contact the water
supplier or local plumber on how to correct
this situation. Do not plug the relief valve.
WARNING:
The temperature pressure relief valve
should be checked for performance every
six months or replaced at intervals not
exceeding 3 years, or more frequently in
areas where there is a high incidence of
water deposits.
Produktspecifikationer
Varumärke: | Bosch |
Kategori: | Pannor & pannor |
Modell: | Compress 3000 |
Behöver du hjälp?
Om du behöver hjälp med Bosch Compress 3000 ställ en fråga nedan och andra användare kommer att svara dig
Pannor & pannor Bosch Manualer
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
24 September 2024
21 September 2024
21 September 2024
19 September 2024
19 September 2024
Pannor & pannor Manualer
- Pannor & pannor Electrolux
- Pannor & pannor ATAG
- Pannor & pannor AEG
- Pannor & pannor Philips
- Pannor & pannor Panasonic
- Pannor & pannor BEKO
- Pannor & pannor Inventum
- Pannor & pannor Junkers
- Pannor & pannor Nefit
- Pannor & pannor Remeha
- Pannor & pannor Siemens
- Pannor & pannor Whirlpool
- Pannor & pannor Vaillant
- Pannor & pannor ACV
- Pannor & pannor GE
- Pannor & pannor Orbegozo
- Pannor & pannor Fagor
- Pannor & pannor Gorenje
- Pannor & pannor Hitachi
- Pannor & pannor Teka
- Pannor & pannor Hisense
- Pannor & pannor Vox
- Pannor & pannor Hotpoint
- Pannor & pannor Sencor
- Pannor & pannor Midea
- Pannor & pannor De Dietrich
- Pannor & pannor Solac
- Pannor & pannor Svan
- Pannor & pannor Daikin
- Pannor & pannor Intergas
- Pannor & pannor Stiebel Eltron
- Pannor & pannor Buderus
- Pannor & pannor Dometic
- Pannor & pannor Elco
- Pannor & pannor Dimplex
- Pannor & pannor Masterwatt
- Pannor & pannor Nibe
- Pannor & pannor Ferroli
- Pannor & pannor Haier
- Pannor & pannor Ariston Thermo
- Pannor & pannor Elba
- Pannor & pannor Corberó
- Pannor & pannor Kelvinator
- Pannor & pannor Mora
- Pannor & pannor Buffalo
- Pannor & pannor Viessmann
- Pannor & pannor Franke
- Pannor & pannor Camry
- Pannor & pannor Jocel
- Pannor & pannor Worcester
- Pannor & pannor Atlantic
- Pannor & pannor Technika
- Pannor & pannor Plieger
- Pannor & pannor Bulex
- Pannor & pannor Tesy
- Pannor & pannor Waeco
- Pannor & pannor AWB
- Pannor & pannor HTW
- Pannor & pannor Quooker
- Pannor & pannor Edilkamin
- Pannor & pannor OSO
- Pannor & pannor Kunft
- Pannor & pannor Clage
- Pannor & pannor Noveen
- Pannor & pannor Joven
- Pannor & pannor Daalderop
- Pannor & pannor Cointra
- Pannor & pannor Baxi
- Pannor & pannor Rommer
- Pannor & pannor Biasi
- Pannor & pannor Quantum
- Pannor & pannor Morco
- Pannor & pannor Thermor
- Pannor & pannor Khind
- Pannor & pannor SolarEdge
- Pannor & pannor LERAN
- Pannor & pannor Ygnis
- Pannor & pannor Intellihot
- Pannor & pannor Airthereal
- Pannor & pannor Thermoflow
- Pannor & pannor Apricus
- Pannor & pannor Rinnai
- Pannor & pannor Sime
- Pannor & pannor Kospel
- Pannor & pannor Neopower
- Pannor & pannor My-PV
- Pannor & pannor EvoHeat
- Pannor & pannor Rheem
- Pannor & pannor Mission Air
- Pannor & pannor Solahart
- Pannor & pannor ENEFT
- Pannor & pannor AquaTech
- Pannor & pannor Imarflex
- Pannor & pannor MicroHeat
- Pannor & pannor Noritz
Nyaste Pannor & pannor Manualer
26 Oktober 2024
23 Oktober 2024
23 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024
22 Oktober 2024