Buderus SB625WS Boiler Bruksanvisning

Buderus Panna SB625WS Boiler

Läs nedan 📖 manual på svenska för Buderus SB625WS Boiler (12 sidor) i kategorin Panna. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/12
Read these instructions carefully before installation and operation of the heating system.
Operating Instructions
Stainless Steel Condensing Boiler
Buderus SB625WS/Buderus SB745WS
6 720 805 220-00.1T
DANGER!
The installation instructions included in this Manual are intended solely for
use by a trained and certified installer, service company or the gas supply
company. If the information in this manual is not followed, a fire or explosion
may result causing property damage, personal injury, or death.
Have installation and service performed by a trained and certified
installer or service company, or the gas supply company.
Bosch recommends signing a service and maintenance contract with a
trained and certified installer or service company that covers annual
servicing and condition-based maintenance. Proper maintenance is a
fundamental requirement for safe and efficient operation and long
service life.
The boiler must be serviced annually including the main burner, ignition
burner, the entire venting system, and the combustion air supply. All
parts that show any signs of damage or corrosion must be replaced.
Improper installation, adjustment, alteration, service, or maintenance
can cause property damage, personal injury, or death. Refer to this
manual and consult a trained and certified installer or service company,
or the gas supply company before installation, service or maintenance.
The owner and operator is responsible for the operational safety and
regulatory compliance of the heating system.
THIS MANUAL SHOULD BE HANDED TO THE OWNER AND OPERATOR OF
THE APPLIANCE.
INSTALLER MUST REVIEW ALL SAFETY INSTRUCTIONS WITH THE
OWNER AND OPERATOR.
UPON COMPLETION OF THE INSTALLATION THE INSTALLER MUST
INSTRUCT THE OWNER AND OPERATOR ON THE FUNCTIONALITY AND
THE PROPER OPERATION OF THE BOILER AND THE HEATING SYSTEM
Low temperature condensing boilers for gas/oil fired power burners
6 720 805 220 (2013/02) US/CA
2 | Contents
Stainless Steel Condensing Boiler - SB625WS / SB745WS6 720 805 220 (2012/10)
Contents
1 Key to symbols and safety instructions . . . . . . . . . . . . . . . . . . 3
1.1 Explanation of symbols . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 General safety instructions . . . . . . . . . . . . . . . . . . . . . . . 3
2 Product description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.1 Correct use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.2 Certification and testing mark . . . . . . . . . . . . . . . . . . . . . 5
2.3 Data plate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2.4 The correct fill and make-up water . . . . . . . . . . . . . . . . . 5
2.5 The correct fuel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.6 Combustion Air Quality . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3 System start-up . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3.1 Making the system operational . . . . . . . . . . . . . . . . . . . . 7
3.2 Check and correct the operating pressure . . . . . . . . . . . 7
3.2.1 Checking the operating water pressure . . . . . . . . . . . . . 7
3.2.2 Filling with heating water and bleeding the system . . . . 7
3.3 Starting up the control panel and the burner . . . . . . . . . 7
4 Shutting down the system . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4.1 Switching off the control panel and the burner . . . . . . . 8
4.2 Shutting down the system in an emergency . . . . . . . . . . 8
5 System maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
5.1 Why is regular maintenance important? . . . . . . . . . . . . . 9
5.2 Ordinary analysis and checking, frequency and sampling
points . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Key to symbols and safety instructions | 3
6 720 805 220 (2012/10)Stainless Steel Condensing Boiler - SB625WS / SB745WS
1 Key to symbols and safety instructions
1.1 Explanation of symbols
Warnings
Keywords at the start of a warning indicate the type and seriousness of
the ensuing risk if measures to prevent the risk are not taken.
The following keywords are defined and can be used in this document:
NOTE indicates that property damage may occur.
CAUTION indicates that personal injury may occur.
WARNING indicates that severe personal injury may occur.
DANGER indicates that severe personal injury or death may occur.
Important information
Additional symbols
1.2 General safety instructions
If you hear gas leaking
Leave the building immediately.
Prevent others from entering the building.
Notify the police and fire department from outside the building.
From outside the building, call the gas supply company and a trained
and certified installer or service company.
If you smell gas
Turn off the gas shut-off valve.
Open windows and doors
Do not touch any electrical switch, telephone, and do not use outlets.
Extinguish all open flames.
▶Do not smoke!
Do not use lighters!
Warn all occupants of the building that they need to leave the building.
Do not ring doorbells!
Notify the police and fire department from outside the building.
From outside the building, call the gas supply company and a trained
and certified installer or service company.
If you smell flue gas
Switch off the heating system by shutting off the emergency shut-off
switch.
Open windows and doors.
Call a trained and certified installer or service company.
DANGER: Risk of fatal injury from failing to consider your own
safety!
Never risk your own life. Your own safety must always take the highest
priority
NOTICE: Risk of appliance damage from improper operation of the
boiler!
Only use the boiler for its intended purpose.
Only operate the boiler if it has been installed and maintained per the
instructions provided in the Installation Manual.
Do not attempt to operate an appliance if any part of it is not in
working order or is damaged.
Use only original spare parts! The use of parts not supplied by the
manufacturer may cause damage to the boiler, other property and
personal injury. Also, boiler damage caused by the use of
unauthorized parts is not covered by the warranty.
DANGER: Risk of fire when soldering and brazing!
Take appropriate protective measures when soldering and brazing
around combustible and flammable material.
NOTICE:
The installation must comply with all applicable national, state, and
local codes, rules, and regulations.
The operator is responsible for the operational safety and regulatory
compliance of the heating system.
In the Commonwealth of Massachusetts, the appliance must be
installed by a licensed plumber or gas fitter.
DANGER: Risk of personal injury or death from flue gas poisoning!
Do not install a thermostatic flue gas damper downstream of the draft
hood.
Do not tamper with, remove, or attempt to repair the blocked vent
switch.
When replacing the blocked vent switch, install the new part in the
original location.
A blocked vent switch tripping more than once indicates a problem
with the venting system or chimney which must be repaired
immediately.
Ensure none of the vent pipes and chimneys are damaged or blocked.
Connect only one appliance to each venting system or chimney.
The venting system must not feed into or route through another air
extraction duct.
The venting system must be inspected annually. All parts that show
any signs of damage or corrosion must be replaced.
Never close off or reduce the size of the combustion air openings.
The boiler must not be operated until any obstructions have been
removed.
Warnings in this document are identified by a warning
triangle printed against a grey background.
Important information for the proper use of the boiler is
also provided in this manual. You will find the
information with a symbol shown on the left and
bordered by horizontal lines above and below the text.
Symbol Meaning
Sequence of steps
Cross-reference to other points in this document or to
other documents
Listing/list entry
Listing/list entry (2nd level)
Table 1

Produktspecifikationer

Varumärke: Buderus
Kategori: Panna
Modell: SB625WS Boiler
Enhetsplacering: Ingebouwd
Typ av operation: Draaiknop
Färg på produkten: Zwart
Inbyggd display: Nee
Vikt: 12500 g
Bredd: 590 mm
Djup: 510 mm
Höjd: 49 mm
Sladdlängd: 0.85 m
Typ av material (överst): Glas
Antal brännare/kokzoner: 4 zone(s)
Typ av häll: Gaskookplaat
Antal gasbrännare: 4 zone(s)
Antal elektroniska kokzoner: 0 zone(s)
Kontrollposition: Rechtsboven
Ansluten last (elektrisk): - W
Installationsfackets bredd: 560 mm
Installationsfack djup: 490 mm
Nuvarande: 0.2 A
Ansluten last (gas): 7800 W
Bredd på häll: 59 cm
Strömkälla brännare/kokzon 1: Gas
Strömkälla brännare/kokzon 2: Gas
Strömkälla brännare/kokzon 3: Gas
Strömkälla för brännare/kokzon 4: Gas
Kokzon 1 form: Rond
Kokzon 2 form: Rond
Kokzon 3 form: Rond
Kokzon 4 form: Rond
AC-ingångsspänning: 230 V
AC-ingångsfrekvens: 50 Hz
Inbyggd fläktkåpa: Nee

Behöver du hjälp?

Om du behöver hjälp med Buderus SB625WS Boiler ställ en fråga nedan och andra användare kommer att svara dig




Panna Buderus Manualer

Panna Manualer

Nyaste Panna Manualer