Earth and resistivity tester
EN - User’s manual
C.A 6472
2
Denition of measurement categories
Measurement category IV corresponds to measurements taken at the source of low-voltage installations.
Example: power feeders, counters and protection devices.
Measurement category III corresponds to measurements on building installations.
Example: distribution panel, circuit-breakers, machines or xed industrial devices.
Measurement category II corresponds to measurements taken on circuits directly connected to low-voltage installations.
Example: power supply to electro-domestic devices and portable tools.
PRECAUTIONS FOR USE
This instrument is protected from accidental voltages of not more than 50 V with respect to earth in measurement category IV.
The guaranteed level of protection of this equipment may be compromised if used in a manner not specied by the manufacturer.
Make no measurements on conductors likely to be connected to the network or to earth conductors that
are not disconnected.
Do not exceed the maximum rated voltage and current and the measurement category.
Never exceed the protection limits indicated in the specications.
Comply with the conditions of use, namely the temperature, the humidity, the altitude, the degree of pollution, and the place of use.
Do not use the device or its accessories if they seem damaged.
Use only the charging unit supplied with the tester to recharge the internal battery.
Use connection accessories of which the overvoltage category and service voltage are greater than or equal to those of the
measuring device (50V CAT IV). Use only accessories that comply with safety standards (IEC 61010-2-031 and 32).
Troubleshooting and metrological checks must be done only by accredited skilled personnel.
Wear the appropriate protective gear (insulating boots and gloves).
Foreword:
The potentials on the various rods used for an earth measurement may be dierent if a nearby electrical installation is defective or
certain weather conditions prevail (thunderstorms). It is up to the operator to decide whether to continue or postpone a campaign
of measurements in a given situation.
WARNING, risk of DANGER! The operator must refer to these instructions whenever this danger symbol appears.
Equipment protected by double insulation.
Earth terminal.
CE marking indicates conformity with European directives, in particular LVD and EMC.
The rubbish bin with a line through it indicates that, in the European Union, the product must undergo selective disposal
in compliance with Directive WEEE 2012/19U/EU. This equipment must not be treated as household waste.
Thank you for purchasing a C.A 6472 earth and resistivity tester. To obtain the best service from your unit:
read these operating instructions carefully,
comply with the precautions for use.
3
CONTENTS
1. START-UP ................................................................................................................................................................................ 4
1.1. Unpacking 4 .......................................................................................................................................................................
1.2. Characteristics label 4 .......................................................................................................................................................
1.3. Accessories .................................................................................................................................................................... 5
1.4. Replacement parts 6 .........................................................................................................................................................
1.5. Charging the battery 7 .......................................................................................................................................................
2. PRESENTATION OF THE DEVICE ....................................................................................................................................... 8
2.1. Functions of the device 9 ..................................................................................................................................................
2.2. Keypad 9 ...........................................................................................................................................................................
2.3. Display unit 10 ...................................................................................................................................................................
2.4. Operating principle ........................................................................................................................................................11
3. AUTOMATIC MODE .............................................................................................................................................................. 12
3.1. Resistance measurement 12 .............................................................................................................................................
3.2. 3P earth measurement 15 .................................................................................................................................................
3.3. 4P earth measurement 17 .................................................................................................................................................
3.4. Measurement of soil resistivity .................................................................................................................................. 20 r
3.5. Measurement of earth potential V pot. 24 .........................................................................................................................
3.6. Earth measurements with 2 clamps 26 .............................................................................................................................
4. ERROR REPORTING ........................................................................................................................................................... 27
4.1. Electrode resistance too high 27 .......................................................................................................................................
4.2. Out of range 27 ..................................................................................................................................................................
4.3. Misconnection 27 ..............................................................................................................................................................
4.4. Indicators of limits of use 27 ..............................................................................................................................................
5. MEASUREMENTS IN MANUAL MODE .............................................................................................................................. 29
5.1. Choice of measurement frequency 29 ...............................................................................................................................
5.2. Switching of the measurement voltage 29 .........................................................................................................................
5.3. Manual settings for the resistance measurement 30 ........................................................................................................
5.4. Manual settings for the 3P earth measurement ................................................................................................................ 30
5.5. Manual settings for the 4P earth measurement 31 ............................................................................................................
5.6. Manual settings for the soil resistivity measurement 32 ....................................................................................................
5.7. Manual settings for the earth potential measurement 32 ..................................................................................................
5.8. Manual settings for the measurement with 2 clamps 32 ...................................................................................................
5.9. Sweep mode (SWEEP) 32 ................................................................................................................................................
5.10. Smoothing 32 ..................................................................................................................................................................
6. MEASUREMENTS WITH THE PYLON BOX ...................................................................................................................... 33
6.1. Description of the C.A 6474 Pylon Box and AmpFlex
® sensors 33 ..................................................................................
6.2. Measurements in automatic mode 35 ...............................................................................................................................
6.3. Error reporting 39 ..............................................................................................................................................................
6.4. Manual and sweep modes 39 ............................................................................................................................................
7. MEMORY FUNCTION ........................................................................................................................................................... 41
7.1. Storage of measurement results 41 ..................................................................................................................................
7.2. Retrieval of stored results 42 .............................................................................................................................................
7.3. Erasure of the memory 43 .................................................................................................................................................
8. CONFIGURATION (SETUP) ................................................................................................................................................. 45
8.1. Press the CONFIG key 45 .................................................................................................................................................
8.2. Press the DISPLAY key 46 ................................................................................................................................................
8.3. Press the MEM key 46 ......................................................................................................................................................
8.4. Press the key 46MR .........................................................................................................................................................
8.5. Internal parameters 46 ......................................................................................................................................................
8.6. Check of the display unit 47 ..............................................................................................................................................
9. ERROR MESSAGES ........................................................................................................................................................... 48
10. CONNECTION TO A PC AND ANALYSIS SOFTWARE .................................................................................................. 49
11. SPECIFICATIONS TECHNICAL CHARACTERISTICS AND ......................................................................................... 50
11.1. Reference conditions 50 ..................................................................................................................................................
11.2. Electrical characteristics 50 .............................................................................................................................................
11.3. Power supply 56 ..............................................................................................................................................................
11.4. Environmental conditions 57 ............................................................................................................................................
11.5. Characteristics of construction 57 ....................................................................................................................................
11.6. Conformity to international standards 57 .........................................................................................................................
11.7. Electromagnetic compatibility 58 .....................................................................................................................................
12. TERMS AND DEFINITIONS ............................................................................................................................................... 59
13. GLOSSARY.......................................................................................................................................................................... 60
14. MAINTENANCE ................................................................................................................................................................... 62
14.1. Cleaning 62 .....................................................................................................................................................................
14.2. Replacement of the fuse 62 .............................................................................................................................................
14.3. Replacing the battery 63 ..................................................................................................................................................
15. WARRANTY ........................................................................................................................................................................ 65
Produktspecifikationer
Varumärke: | Chauvin Arnoux |
Kategori: | Mätutrustning |
Modell: | C.A 6472 |
Behöver du hjälp?
Om du behöver hjälp med Chauvin Arnoux C.A 6472 ställ en fråga nedan och andra användare kommer att svara dig
Mätutrustning Chauvin Arnoux Manualer
21 September 2024
21 September 2024
21 September 2024
21 September 2024
21 September 2024
21 September 2024
21 September 2024
21 September 2024
18 September 2024
18 September 2024
Mätutrustning Manualer
- Mätutrustning Bosch
- Mätutrustning Panasonic
- Mätutrustning DeWalt
- Mätutrustning Fysic
- Mätutrustning Honeywell
- Mätutrustning Pioneer
- Mätutrustning Albrecht
- Mätutrustning Alecto
- Mätutrustning Amprobe
- Mätutrustning Yato
- Mätutrustning Lanaform
- Mätutrustning Megasat
- Mätutrustning Meec Tools
- Mätutrustning Milwaukee
- Mätutrustning Extech
- Mätutrustning Victron Energy
- Mätutrustning Hazet
- Mätutrustning Metrix
- Mätutrustning Benning
- Mätutrustning Einhell
- Mätutrustning Voltcraft
- Mätutrustning Midland
- Mätutrustning Mitsubishi
- Mätutrustning Velleman
- Mätutrustning Vemer
- Mätutrustning Perel
- Mätutrustning Kyoritsu
- Mätutrustning IFM
- Mätutrustning Ideal
- Mätutrustning Flir
- Mätutrustning Grohe
- Mätutrustning Technoline
- Mätutrustning Soler And Palau
- Mätutrustning Continental Edison
- Mätutrustning Rossmax
- Mätutrustning Carrier
- Mätutrustning Testboy
- Mätutrustning Goclever
- Mätutrustning Trotec
- Mätutrustning LaCie
- Mätutrustning Danfoss
- Mätutrustning Hager
- Mätutrustning Bresser
- Mätutrustning TFA
- Mätutrustning Owon
- Mätutrustning Flex
- Mätutrustning Fluke
- Mätutrustning Fantini Cosmi
- Mätutrustning Eltako
- Mätutrustning EBERLE
- Mätutrustning Basetech
- Mätutrustning Stabila
- Mätutrustning Be Cool
- Mätutrustning Laserliner
- Mätutrustning Wentronic
- Mätutrustning REV
- Mätutrustning Testo
- Mätutrustning Clean Air Optima
- Mätutrustning Eastron
- Mätutrustning ORNO
- Mätutrustning RIDGID
- Mätutrustning Westfalia
- Mätutrustning Monacor
- Mätutrustning Multimetrix
- Mätutrustning GW Instek
- Mätutrustning Logilink
- Mätutrustning SIIG
- Mätutrustning Oregon Scientific
- Mätutrustning Etymotic
- Mätutrustning Reely
- Mätutrustning Muller
- Mätutrustning TFA Dostmann
- Mätutrustning Werma
- Mätutrustning Greisinger
- Mätutrustning Beha-Amprobe
- Mätutrustning Kopp
- Mätutrustning Kern
- Mätutrustning Kogan
- Mätutrustning Kreg
- Mätutrustning Pancontrol
- Mätutrustning Peak
- Mätutrustning Uni-T
- Mätutrustning H-Tronic
- Mätutrustning Elgato
- Mätutrustning Hikmicro
- Mätutrustning PeakTech
- Mätutrustning Sonel
- Mätutrustning Tru Components
- Mätutrustning Emko
- Mätutrustning Aktobis
- Mätutrustning Entes
- Mätutrustning KS Tools
- Mätutrustning Lund
- Mätutrustning Trumeter
- Mätutrustning Delta Ohm
- Mätutrustning Hanna
- Mätutrustning MGL Avionics
- Mätutrustning Adwa
- Mätutrustning Megger
- Mätutrustning AREXX
- Mätutrustning Gossen Metrawatt
- Mätutrustning PCE Instruments
- Mätutrustning CEM
- Mätutrustning SHX
- Mätutrustning Hameg
- Mätutrustning TDE Instruments
- Mätutrustning Joy-it
- Mätutrustning Circutor
- Mätutrustning Wachendorff
- Mätutrustning Klein Tools
- Mätutrustning Duro Pro
- Mätutrustning GMW
- Mätutrustning Janitza
- Mätutrustning Sanwa
- Mätutrustning J.P. Instruments
- Mätutrustning MSW
- Mätutrustning Weidmüller
- Mätutrustning Qubino
- Mätutrustning Lascar Electronics
- Mätutrustning HT Instruments
- Mätutrustning P3 International
- Mätutrustning Beckmann & Egle
- Mätutrustning Seek Thermal
- Mätutrustning INFICON
- Mätutrustning Motrona
- Mätutrustning Tempo
- Mätutrustning Camille Bauer
- Mätutrustning Blebox
- Mätutrustning Seaward
- Mätutrustning HOZO Design
- Mätutrustning Corentium
- Mätutrustning GQ
- Mätutrustning Tektronix
- Mätutrustning Dostmann Electronic
- Mätutrustning Murideo
- Mätutrustning SecuTech
- Mätutrustning NetPeppers
- Mätutrustning SensoProtect
- Mätutrustning Water-i.d.
- Mätutrustning ZKETECH
- Mätutrustning LabNation
- Mätutrustning Electronics International
- Mätutrustning Cliff
- Mätutrustning ClimeMET
- Mätutrustning Fixpoint
- Mätutrustning Kübler
- Mätutrustning AkYtec
- Mätutrustning Stahlwille
- Mätutrustning MASIMO
- Mätutrustning Milesight
- Mätutrustning Enda
- Mätutrustning CSL
- Mätutrustning Ermenrich
- Mätutrustning PICO
- Mätutrustning Siglent
- Mätutrustning Noyafa
- Mätutrustning Stamos
Nyaste Mätutrustning Manualer
26 Oktober 2024
25 Oktober 2024
25 Oktober 2024
24 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024