Installation, Operation & Maintenance Manual
260APC-A
PRESSURE STEAMERS
SERIES: , , , ,PGM PEM PSM PDM PDL-2/3
Operator’s Manual P/N-260APC-A
______________________________________________________________________________
2
Table of Contents
INSTALLATION 3
Correct Installation 3
Water Quality 3
Drain Line Connection 4
Installation Safety 4
Installation Instructions 5
Installation checks 5
Gauge Pressure Reading with No Steam Flow* (Static Pressure) 7
OPERATION 7
Controls and Controls Panels 7
Steam Generator Controls 7
Start-up and Preheat 8
Cooking Operations 8
Startup and Preheat 9
Cooking Operation 9
Boiler Shutdown 9
Care and Cleaning 9
MAINTENANCE 10
Preventative Maintenance-Descaling Instructions 11
TROUBLESHOOTING 15
Operators Troubleshooting Guide 16
Troubleshooting Notes 16
PRESSURE STEAMER COOKING INFORMATION 17
Operator’s Manual P/N-260APC-A
______________________________________________________________________________ 3
Installation
CORRECT INSTALLATION
You have purchased the finest Steam Cooking Equipment
made. The following information we know will increase the
productivity and life span of the equipment.
Every product needs proper installation and with a
steamer it is critical. The following is some important
information you should check on before and during
installation of the equipment.
Water
The quality of water you put into the steam generator is
important. Poor quality water will create generator prob-
lems.
Water is no longer just plain and simple. Water has many
natural ingredients in it. These are called Total Dissolved
Solids, or TDS. This includes calcium, iron, and other
minerals in the water that collect in the steam generator
Because of the droughts in many areas, water and TDS's
are being pumped up from the bottom of the water
systems. If these TDS are not pre-filtered out or cleaned
out with a regular preventive maintenance program, your
steam generator could deteriorate and develop holes.
CHLORIDE is another chemical in our water creating
many problems with all steam generators. When the gen-
erator creates steam from the water it also carries the
chloride gas with it. These chlorides begin to eat away the
inside of the generator and follow the steam into the
compartments causing a rusting action (oxidation) as it
goes along.
A CARBON OR CHARCOAL FILTER must be installed on
the incoming water line to the steamer if the chlorine is
over 30 parts per million. These filters will remove the
chloride.
The WATER QUALITY REQUIREMENTS for your
STEAMER are as follows:
Total Dissolved Solids less than 60 parts per million
Total Alkalinity less than 20 parts per million
Silica less than 13 parts per million
Chlorides less than 30 parts per million
pH Factor greater than 7.5
Drain Line Connection
A proper drain line connection is important. If the drain
line is clogged it can create a back up of pressure causing
extreme and costly repairs.
Figure 1. Drain Connections
If the drain line is not large enough, not open at the end,
or does not have a gravity flow; pressure and hot water
will back up into the compartments. If any of these condi-
tions exist and hot water does back up into the compart-
ment someone could be seriously burned and injured.
This can happen even with a correct installation if a drain
cleaner is not used on a regular basis.
An open and free flowing drain line IS REQUIRED for the
proper cooking performance of a CONVECTION
STEAMER. It helps create a swirling action around the
products being cooked. This movement of hot steam
around the product is your CONVECTION STEAM
COOKING.
DO NOT INSTALL UNIT OVER A FLOOR DRAIN. If it
becomes an absolute must, using an 18.' stainless steel
or aluminum pan turn it over and cut a notch in the side
wall to fit over the drain line. Place the pan directly over
the drain opening- DO NOT SEAL TO THE FLOOR. The
steam from the drain line will collect on the under side and
condense into the drain opening.
DO NOT INSTALL GAS UNITS ON
FLAMMABLEFLOORS OR NEAR WALLS. A flammable
floor or wall is any material such as wood, linoleum, or
vinyl that is easily ignitable and bums rapidly.
The intent of these instructions is to provide meaningful
information, which will help you obtain many years of
production. Before installing the steamer, please read
those instructions carefully to maintain your safety and
warranty.

Produktspecifikationer

Varumärke: Cleveland
Kategori: Generator
Modell: PDL2
Enhetsplacering: Ingebouwd
Typ av operation: Buttons, Rotary
Färg på produkten: Zwart
Inbyggd display: Ja
Bredd: 594 mm
Djup: 567 mm
Höjd: 595 mm
Grill: Ja
Wi-Fi-kontroll: Ja
Energie-efficiëntieklasse: A
Belysning inuti: Ja
Integrerad klocka: Ja
Typ av klocka: Elektronisch
Konvektionsmatlagning: Ja
Antal lampor: 1 lampen
Typ av lampa: Halogeen
Total inomhuskapacitet (ugnar): 65 l
Antal ugnar: 1
Lätt att städa: Ja
Kontrollposition: Voorkant
Installationsfackets bredd: 560 mm
Installationsfack djup: 550 mm
Installationsfack höjd: 600 mm
Typ av rengöring: Stoom
Nuvarande: 16 A
Material genom: Glas
Antal glasdörrpaneler: 2
Energiförbrukning (konventionell): - kWu
Energiförbrukning (tvungen konvektion): - kWu
Att laga: Ja
Ugnsstorlek: Middelmaat
Typ av ugn: Elektrische oven
Total ugnseffekt: 2400 W
Ugn med nettokapacitet: 65 l
Över- och undervärme: Ja
Bakplåtsmått: Ja
Självrengörande: Ja
Avtagbart dörrglas: Ja
Antal bakplåtar: 2
Varmluftsgrillning: Ja
Antal matlagningsprogram: 7
Snabb värme: Ja
Innermått (B x D x H): 555 x 547 x 570 mm
Uppvärmning av hela grillytan: Ja
AC-ingångsspänning: 220 - 240 V
AC-ingångsfrekvens: 50 - 60 Hz
Type beeldscherm: LED
Ugnsavfrostningsfunktion: Ja

Behöver du hjälp?

Om du behöver hjälp med Cleveland PDL2 ställ en fråga nedan och andra användare kommer att svara dig




Generator Cleveland Manualer

Generator Manualer

Nyaste Generator Manualer