Crestron CLW-LSWEX-2GD Bruksanvisning

Crestron Växla CLW-LSWEX-2GD

Läs nedan 📖 manual på svenska för Crestron CLW-LSWEX-2GD (2 sidor) i kategorin Växla. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
CLW-LSWEX-1GD/CLW-LSWEX-1GU/CLW-LSWEX-2GD
Wireless Lamp Switch
Installation and Operation Guide
Description
The CLW-LSWEX-1GD, CLW-LSWEX-1GU, and CLW-LSWEX-2GD are plug-in switches
designed to operate as part of a complete Crestron
® automation system communicating
via the inNET EX® wireless control network. Without the need for additional control wiring,
the CLW-LSWEX-1GD, CLW-LSWEX-1GU, and CLW-LSWEX-2GD easily act in place of a
standard light switch for conventional oor and table lamps.
The CLW-LSWEX-1GD, CLW-LSWEX-1GU, and CLW-LSWEX-2GD are functionally
identical. For simplicity within this guide, the term “CLW-LSWEX” is used except where
noted.
CLW-LSWEX Specications
Installation
NOTE: Before using the CLW-LSWEX, ensure the device is using the latest rmware.
Check for the latest rmware for the CLW-LSWEX at www.crestron.com/rmware.
Firmware is loaded onto the device using Crestron Toolbox™.
To install the CLW-LSWEX:
1. Plug the CLW-LSWEX into a wall outlet.
2. Use the wall plate screw to secure the CLW-LSWEX to the wall plate (optional).
3. Plug the controlled lamp(s) into the receptacle(s) located on the bottom of the
CLW-LSWEX.
4. Acquire the CLW-LSWEX to the inNET EX network.
Additional Resources
Visit the product page on the Crestron website (www.crestron.com)
for additional information and the latest rmware updates. Use a QR
reader application on your mobile device to scan the QR image.
* The load can be split across both channels in the CLW-LSWEX-2GD.
Operation
Refer to the following diagram when operating the CLW-LSWEX.
Operating the CLW-LSWEX (CLW-LSWEX-2GD Shown)
Wireless Communications
The device connects to the Crestron network via the inNET EX communications protocol.
Use the procedures outlined below to join or leave an inNET EX network and to verify
communications between the device and the control system.
Joining an inNET EX Network
Before a device can be used in a lighting system, it must rst join an inNET EX network.
To join an inNET EX network, the device must be acquired by an inNET EX gateway.
NOTE: A device can be acquired by only one gateway.
1. Put the inNET EX gateway into Acquire mode from the unit itself or from Crestron
Toolbox. Refer to the gateway’s manual at www.crestron.com/manuals for details.
NOTE: In an environment where multiple gateways are installed, only one
gateway should be in Acquire mode at any time.
2. Put the device into Acquire mode.
a. Tap button 1 on the device three times, and then press and hold it down
(tap-tap-tap-press+hold) until the LED on the device blinks once (this can take up
to 10 seconds).
NOTE: On the CLW-LSWEX-2GD, button 1 or 2 can be used.
b. Release the button to start the acquire process. The top LED blinks slowly to
show that the device is actively scanning the inNET EX network.
The LED turns on for 5 seconds to show that the device has been successfully
acquired by the infiNET EX network.
The LED blinks fast to indicate that the device was not successfully acquired
by the infiNET EX network. Tap the top button to acknowledge the failure.
Ensure the gateway is in Acquire mode and within range before attempting the
acquire process again.
3. Once all devices have been acquired, take the gateway out of Acquire mode. Refer
to the gateway’s manual for details.
Leaving an inNET EX Network
To leave an inNET EX network, put the device into Acquire mode, as described in
“Joining an inNET EX Network” above, when no gateway is in Acquire mode.
Verifying Communications Status
To check the communications status of the device, tap the button three times, and then
press and hold it down (tap-tap-tap-press+hold) for up to 2 seconds. The LED blinks to
indicate the communications status. Refer to the following table for details.
Load 1 receptacle Load 2 receptacle
(CLW-LSWEX-2GD only)
Button 1:
Press this button to toggle
load 1 on and off.
The green LED lights to indicate
that the receptacle is energized.
Button 2 (CLW-LSWEX-2GD Only):
Press this button to toggle
load 2 on and off.
The green LED lights to indicate
that the receptacle is energized.
Troubleshooting
The following table provides corrective actions for possible trouble situations. If further
assistance is required, please contact a Crestron customer service representative.
CLW-LSWEX Troubleshooting
SPECIFICATION DETAILS
Power Requirements 120 Vac, 60 Hz
Load Ratings
Incandescent/
Tungsten Halogen
600 W total*
Magnetic Low-Voltage 600 VA / 450 W total*
Environmental
Temperature 32 °F to 104 °F (0 °C to 40 °C)
Humidity 10% to 90% RH (noncondensing)
TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION
The lamp does not
function.
The CLW-LSWEX is not
plugged into a live wall
outlet.
Verify that the
CLW-LSWEX is plugged
into an ac outlet and that
the circuit breaker is
closed. The green LED
on the CLW-LSWEX
lights when the device is
energized.
The lamp is not turned on. Turn on the load locally
at the lamp (i.e. at the
lamp switch).
The lamp is not connected
to the CLW-LSWEX.
Connect the lamp to the
CLW-LSWEX.
The lamp cannot be
controlled from the control
system.
The CLW-LSWEX is not
acquired to the network.
Acquire the
CLW-LSWEX to the
network.
LED COMMUNICATIONS STATUS
Turns on for 5 seconds The device is communicating with the control system.
Blinks three times The device is communicating with the gateway, but the
gateway is not communicating with the control system.
Blinks twice The device is not communicating with the gateway.
Blinks once The device is acquired but is not communicating with
the network.
Stays off The device is not joined to the network.
This product is Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Federal Communications Commission (FCC) Compliance Statement
This device complies with part 15 of the FCC Rules. Operation is subject to the following two
conditions: (1) This device may not cause harmful interference, and (2) this device must accept any
interference received, including interference that may cause undesired operation.
CAUTION: Changes or modications not expressly approved by the manufacturer responsible for
compliance could void the user’s authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase separation between the equipment and the receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Industry Canada (IC) Compliance Statement
Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device may accept any interference, including interference that may cause undesired
operation of the device.
Crestron Electronics, Inc. Installation & Operation Guide - DOC. 6835B
15 Volvo Drive Rockleigh, NJ 07647 (2024689)
Tel: 888.CRESTRON 11.15
Fax: 201.767.7576 Specications subject to
www.crestron.com change without notice.
To satisfy RF exposure requirements, this device and its antenna must operate with a separation
distance of at least 20 centimeters from all persons and must not be colocated or operating in
conjunction with any other antenna or transmitter.
The product warranty can be found at www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at patents.crestron.com.
Certain Crestron products contain open source software. For specic information, please visit
www.crestron.com/opensource.
Crestron, the Crestron logo, Crestron Toolbox, inNET EX, and the inNET EX logo are either
trademarks or registered trademarks of Crestron Electronics, Inc. in the United States and/or other
countries. UL and the UL logo are either trademarks or registered trademarks of Underwriters
Laboratories, Inc. in the United States and/or other countries. Other trademarks, registered
trademarks, and trade names may be used in this document to refer to either the entities claiming the
marks and names or their products. Crestron disclaims any proprietary interest in the marks and
names of others. Crestron is not responsible for errors in typography or photography.
This document was written by the Technical Publications department at Crestron.
©2015 Crestron Electronics, Inc.

Produktspecifikationer

Varumärke: Crestron
Kategori: Växla
Modell: CLW-LSWEX-2GD

Behöver du hjälp?

Om du behöver hjälp med Crestron CLW-LSWEX-2GD ställ en fråga nedan och andra användare kommer att svara dig




Växla Crestron Manualer

Växla Manualer

Nyaste Växla Manualer