GLS-REMOTE-ODT/OIR
IR Remote for GLS Occupancy Sensors
Operations Guide
Description
The Crestron® GLS-REMOTE-ODT/OIR is a compact IR
wireless remote designed specically for setting up and
commissioning a GLS-ODT-C-CN, GLS-ODT-C-NS,
GLS-OIR-C-CN, or GLS-OIR-C-NS. The
GLS-REMOTE-ODT/OIR provides buttons for
programming and setting up the sensor without the
need for a laptop computer or ladder. The
GLS-REMOTE-ODT/OIR operates on two AAA batteries
(included).
GLS-REMOTE-ODT/OIR Physical View
2. Congure the Sensor
After entering OCC Setup mode or VAC mode, the sensor can be congured.Setup
Additional Resources
Visit the product page on the
Crestron website
(www.crestron.com) for additional
information and the latest rmware
updates.
GLS-REMOTE-ODT/OIR
OCC
SETUP
VAC
SETUP
EXIT
SETUP
30s 2m 5m
10m 15m 30m
DISABLE
DISABLE
ENABLE
ENABLE
US
OFF
US
LOW
US
MED
US
HIGH
PIR
OFF
PIR
LOW
PIR
MED
PIR
HIGH
B
ONLY
A
ONLY
A+B
1234
RESET
FORCE
VAC
SET
ID
1. Enter a Setup Mode
During operation of the remote, the sensor will emit one
short beep for a successful entry and one short beep
followed by long beep for an unsuccessful entry. The
sensor will emit two short beeps when a setup mode is
exited.
To enter a setup mode, press and hold the OCC SETUP
or VAC SETUP button for 3 seconds. To exit either setup
mode press the button. ,EXIT SETUP
Setup Mode Table
COMMAND DESCRIPTION
OCC SETUP OCC Setup mode allows the user
to configure the sensitivity of the
sensor when it is in an occupied
state.
Press and hold for 3 seconds to
place the sensor into OCC Setup
mode.
VAC SETUP VAC Setup mode allows the user to
configure the sensitivity of the
sensor when it is in a vacant state.
Press and hold for 3 seconds to
place the sensor into VAC Setup
mode.
While in VAC Setup mode, the
sensor beeps to indicate that
motion is detected.
EXIT SETUP Press to exit the active setup mode
and return the sensor to normal
operation.
The sensor exits the active setup
mode if no buttons are pressed on
the remote for 5 minutes.
COMMAND DESCRIPTION
TIMEOUT
(30s, 2m, 5m, 10m,
15m, 30m)
SHORT TIMEOUT
(ENABLE / DISABLE)
US
(A+B, A ONLY,
B ONLY)
These buttons set the time that the sensor must not see any motion before going to the
vacant state. Timeout settings may be applied in OCC Setup or VAC Setup modes.
These buttons enable or disable Short Timeout mode. Short Timeout mode limits the
timeout to 60 seconds for the rst 90 seconds of occupancy after which the normal timeout
applies. Short timeout settings may be applied in OCC Setup or VAC Setup modes.
Th enable or disable some or all of the ultrasonic (US) sensors. The A and B ese buttons
sensor banks are labeled under the cover of the sensor. If the sensor is not accessible, the
A sensor bank is on the same side as the red LED and the B sensor bank is on the same
side as the green LED. US settings may be applied in OCC Setup or VAC Setup modes.
A+B enables both banks of the ultrasonic sensors.
A ONLY enables bank A and disables bank B.
B ONLY enables bank B and disables bank A.
LED
(ENABLE, DISABLE)
SENSITIVITY
(PIR HIGH,
PIR MED, PIR LOW /
PIR OFF)
SENSITIVITY
(US HIGH, US MED,
US LOW, US OFF)
SET ID
Press these buttons to enable or disable the LEDs during normal operation. The green LED
is for US detection and the red LED is for PIR detection. The LEDs are always enabled
during a setup mode. LED settings may be applied while in OCC Setup or VAC Setup
mode.
When in OCC Setup mode, these buttons set the sensitivity of the passive infrared (PIR)
sensor while the room is occupied. When in VAC Setup mode, the set the sensitivity of y
the PIR sensor while the room is vacant. Settings for PIR LOW, PIR MED, or PIR HIGH
indicate the sensitivity to motion. PIR OFF disables the PIR sensor regardless of which
state the sensor is in.
Refer to the “Detection Range” section in the sensor’s installation guide at
www.crestron.com/manuals for more information on sensitivity.
When in OCC Setup mode, th the sensitivity of the US sensor while the ese buttons set
room is occupied. When in VAC Setup mode, th the sensitivity of the US sensor while ey set
the room is vacant. Settings for US LOW, US MED, or US HIGH indicate sensitivity to
motion. US OFF disables the ultrasonic sensors regardless of the sensor state.
Refer to the “Detection Range” section in the sensor’s installation guide for more
information on sensitivity.
This button sets or changes the Net ID of the sensor.
1. Press and hold the button for 3 seconds. The sensor emits 3 short beeps SET ID
to indicate that it is ready for Net ID entry.
2. Enter the Net ID of the sensor using the numeric keypad on the remote. The
sensor emits 1 short beep for each number entry.
3. Press to conrm the entry. The sensor emits one long beep to indicateSET ID
successful Net ID entry and three short beeps to indicate failed entry.
RESET Hold this button for 3 seconds to reset the sensor back to its factory default settings. The
Net ID is not changed during device reset. The factory settings are listed below:
Remote Timeout: 0 minutes
Local Timeout: 5 minutes
Short Timeout: Disabled
US: A+B enabled
LED: Enabled
Sensitivity: PIR medium and US medium
FORCE VAC Hold this button for 3 seconds to force the sensor to enter the vacant state. The sensor
ignores triggers for 5 seconds and then reverts to normal operation.
CUSTOM
(1, 2, 3, 4)
These buttons are reserved for future custom programming.
As of the date of manufacture, the GLS-REMOTE-ODT/OIR
has been tested and found to comply with specifications for
CE marking.
Federal Communications Commission (FCC) Compliance
Statement
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device
must accept any interference received, including interference
that may cause undesired operation.
CAUTION: Changes or modications not expressly approved
by the manufacturer responsible for compliance could void
the user’s authority to operate the equipment.
Crestron Electronics, Inc.
15 Volvo Drive
Rockleigh, NJ 07647
Tel: 888.CRESTRON
Fax: 201.767.7576
www.crestron.com
Operations Guide DOC.
7541C
(2036947)
05.15
Specications subject to
change without notice.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the
FCC Rules. These limits are designed to provide reasonable
protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause
harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the
interference at his own expense.
Industry Canada (IC) Compliance Statement
CAN ICES-3(B)/NMB-3(B)
The product warranty can be found at
www.crestron.com/warranty.
The specic patents that cover Crestron products are listed at
patents.crestron.com.
Crestron, the Crestron logo are either trademarks or registered
trademarks of Crestron Electronics, Inc. in the United States
and/or other countries. Other trademarks, registered trademarks,
and trade names may be used in this document to refer to either
the entities claiming the marks and names or their products.
Crestron disclaims any proprietary interest in the marks and names
of others. Crestron is not responsible for errors in typography or
photography.
This document was written by the Technical Publications
department at Crestron.
©2015 Crestron Electronics, Inc.

Produktspecifikationer

Varumärke: Crestron
Kategori: Fjärrkontroll
Modell: GLS-REMOTE-ODT/OIR

Behöver du hjälp?

Om du behöver hjälp med Crestron GLS-REMOTE-ODT/OIR ställ en fråga nedan och andra användare kommer att svara dig




Fjärrkontroll Crestron Manualer

Fjärrkontroll Manualer

Nyaste Fjärrkontroll Manualer