MODEL: OR1500LCDRM2U, OR2200LCDRM2U, OR1500LCDRTXL2U,

MODEL: PR1000LCD
MODEL: PR1500LCD
1. Remove the front panel of the UPS.
2. Remove two screws from the battery compartment cover and slide the cover completely off of
the unit.
3. Remove the batteries from the compartment. Disconnect the battery wires from the batteries.
4. Install the replacement batteries by connecting the wire bundle (composed of one red wire and
one black wire) to the connector from the battery pack.
5. Put the batteries back into the compartment. Re-install the battery compartment cover and
tighten the retaining screws. Put the front panel back on the UPS.
6. Connect to AC power and charge the new batteries for up to 16 hours to insure a full charge
MODEL: PR750LCDRM1U, PR1000LCDRM1U
1. Remove the right side front panel.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Disconnect the black and red cable.
4. Remove the one retaining screw holding the battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
sequence of the above steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR1500SWRM2U, PR2200SWRM2U
1. Remove the right side front panel.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Disconnect the black and red cable.
4. Remove the four retaining screws holding the battery pack in place.
5. Remove the battery pack.
6. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR1000LCDRT2U, PR1000LCDRTXL2U, PR1500LCDRT2U,
PR2200LCDRT2U, PR3000SWRM2U
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the four retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR1000LCDRTXL2Ua, PR1500LCDRTXL2U, PR2200LCDRTXL2U,
PR3000LCDRT2U, PR3000LCDRTXL2Umart
1. Remove the six retaining screws, and remove the front panel from the UPS.
2. Remove the two retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the three retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
MODEL: PR5000LCDRTXL5U, PR6000LCDRTXL5U
1. Remove the front panel.
2. Remove the two retaining screws of the cable protection cover and remove the cover.
3. Pull the plastic sticker out slowly to remove the battery module.
4. Put the new battery modules back into the compartment.
5. Tighten the screws and replace the cable protection cover and the front panel.
PFC SINEWAVE Series
MODEL: CP850PFCLCD, CP1000PFCLCD
1. Turn the UPS on its side. Remove the retaining screw located on the bottom of the UPS.
2. Slide the battery compartment cover completely off of the unit.
3. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same
color connectors from the battery pack. Put the batteries back into the compartment.
6. Slide back the battery compartment cover and tighten the retaining screw. Recharge the UPS

for 8-16 hours to fully charge the battery.
MODEL: CP1350PFCLCD
1. Turn the UPS on its side. Remove the front panel retaining screws located on the bottom of the
UPS.
2. Slide the battery compartment cover (front panel) completely off of the unit.
3. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
5. Install the replacement batteries by connecting the red wire (+) and black wire (-) to the same
color connectors from the battery pack. Put the batteries back into the compartment.
6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS
for 8-16 hours to fully charge the battery.
MODEL: CP1500PFCLCD
1. Turn the UPS on its side. Remove the front panel retaining screws located on the bottom of the
UPS.
2. Slide the battery compartment cover (front panel) completely off of the unit.
3. Remove the batteries from the compartment.
4. Disconnect the battery wires from the batteries.
5. Install the replacement batteries by connecting the wire bundle (composed of one red wire and
one black wire) to the connector from the battery pack. Put the batteries back into the
compartment.
6. Slide back the battery compartment cover and tighten the retaining screws. Recharge the UPS
for 8-16 hours to fully charge the battery.
MODEL: OR1500PFCRT2U, OR2200PFCRT2U
1. Remove the right side front panel.
2. Remove the three retaining screws for the cable protection cover and remove the cover.
3. Remove the two retaining screws from the cable connectors.
4. Disconnect the black and red cable.
5. Remove the four retaining screws holding the battery pack in place.
6. Remove the battery pack.
7. Install the new battery pack. Assemble the screws, cover, cable and front panel in the reverse
order of the previous steps. Charge the unit for 4-8 hours to ensure the UPS performs expected
runtimes.
Produktspecifikationer
Varumärke: | CyberPower |
Kategori: | Accu |
Modell: | RB1290X16 |
Behöver du hjälp?
Om du behöver hjälp med CyberPower RB1290X16 ställ en fråga nedan och andra användare kommer att svara dig
Accu CyberPower Manualer

24 December 2024

26 September 2024

26 September 2024

26 September 2024

26 September 2024

26 September 2024

26 September 2024

26 September 2024

26 September 2024

26 September 2024
Accu Manualer
- Accu Sony
- Accu LG
- Accu Bosch
- Accu Huawei
- Accu Panasonic
- Accu DeWalt
- Accu Epson
- Accu JVC
- Accu Nikon
- Accu Canon
- Accu Apc
- Accu Aluratek
- Accu Ansmann
- Accu A-solar
- Accu Vetus
- Accu Hikvision
- Accu Arris
- Accu Ozito
- Accu Leica
- Accu Nedis
- Accu Black And Decker
- Accu Vonroc
- Accu Hilti
- Accu Ryobi
- Accu Targus
- Accu Metabo
- Accu Parkside
- Accu Worx
- Accu Trust
- Accu Milwaukee
- Accu Hähnel
- Accu Victron Energy
- Accu Cramer
- Accu Berg
- Accu Tripp Lite
- Accu Stinger
- Accu Toa
- Accu Energenie
- Accu Einhell
- Accu Hama
- Accu Fujifilm
- Accu Kensington
- Accu Sennheiser
- Accu Techly
- Accu Varta
- Accu Husqvarna
- Accu Petzl
- Accu Sandberg
- Accu Biltema
- Accu Digitus
- Accu Nitecore
- Accu Belkin
- Accu DJI
- Accu Powerplus
- Accu Stiga
- Accu Growatt
- Accu Deltaco
- Accu Cobra
- Accu Valcom
- Accu McCulloch
- Accu Speed-Link
- Accu Cortina
- Accu Carat
- Accu Shure
- Accu Conrad
- Accu Kress
- Accu Mestic
- Accu Fluke
- Accu For_Q
- Accu Greenworks
- Accu HQ
- Accu Fuxtec
- Accu Xtorm
- Accu Ranex
- Accu Watson
- Accu Scosche
- Accu Anton/Bauer
- Accu Cocraft
- Accu Impact
- Accu SKROSS
- Accu Arctic Cooling
- Accu Ergotron
- Accu Crestron
- Accu Toolcraft
- Accu Monacor
- Accu Energizer
- Accu Fein
- Accu Bolt
- Accu Team Orion
- Accu SolarEdge
- Accu BlackVue
- Accu Venom
- Accu Duracell
- Accu Inovonics
- Accu Anova
- Accu Red Power
- Accu Sungrow
- Accu Ultron
- Accu Enphase
- Accu EGO
- Accu E-flite
- Accu Whistler
- Accu PNY
- Accu PowerDrive
- Accu LSI
- Accu Variotek
- Accu Neewer
- Accu Lenmar
- Accu Renata
- Accu Fxlion
- Accu PowerBass
- Accu SOUNDBOKS
- Accu Aim TTi
- Accu FeinTech
- Accu Verico
- Accu Levolta
- Accu HART
- Accu APSystems
- Accu TCW Technologies
- Accu Enerdrive
- Accu Tecnoware
- Accu Ventev
- Accu PAG
Nyaste Accu Manualer

2 April 2025

20 Februari 2025

20 Februari 2025

31 Januari 2025

29 Januari 2025

25 Januari 2025

4 Januari 2025

3 Januari 2025

1 Januari 2025

31 December 2025