Ei Electronics Ei414RF Bruksanvisning

Läs nedan 📖 manual på svenska för Ei Electronics Ei414RF (32 sidor) i kategorin Inte kategoriserad. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/32
Instruction Manual
Read and etain carefully for as long as the product is being used. It contains vital information on the operation and installation of your r
Fire / CO Alarm Interface. The booklet should be regar oduct.ded as part of the pr
If you are just installing the unit, the booklet must be given to the householder. The booklet is to be given to any subsequent user.
Model: Ei414
Fire / CO Alarm Interface
Contents
1. Introduction & Connection Diagrams ........................................................................................
2. Typical Installation Examples ..........................................................................................................
3. Installation ............................................................................................................................................
4. House Coding .......................................................................................................................................
5. Testing ....................................................................................................................................................
6. Service Relay ........................................................................................................................................
7. User Information ................................................................................................................................
8. Troubleshooting the RadioLINK .....................................................................................................
9. Technical Specification .....................................................................................................................
10. Service & Guarantee .........................................................................................................................
11. Contact Us ............................................................................................................................................
3
8
11
18
22
23
24
26
27
28
32
Page
2
1. Introduction
The Ei414 Fire / CO Alarm Interface can be used to connect Ei Electronics RadioLINK Alarm Systems to
suitable other Systems such as Fire Panels, Telecare Systems, Auto Diallers, Security Systems etc. The Ei414
has 3 output relays for Fire, CO & Service that can be triggered by an Ei Electronics RF Alarm System. These relays
can be directly connected to the other Systems or alternatively can be used to trigger one of the other Systems
RF transmitters. A RadioLINK system consists of Ei Electronics RadioLINK Smoke, Heat and CO Alarms along with
RadioLINK accessory devices that are interconnected using the Ei Electronics proprietary RF protocol system. The
Ei414 must be House Coded to the other RadioLINK devices in the system.
se rvice
ON TEST
OFF
Fi / CO Alarm Int erfacere
Alarm Code LED’s
RadioLink LED Power LED
Key Switch
On
Off
Test
open screws
then insert screwdriver into the notch to remove cover
How to remove Cover
Fi / CO Alarm Interfacere