Electia BXA-8 Bruksanvisning

Läs nedan 📖 manual på svenska för Electia BXA-8 (32 sidor) i kategorin Larmsystem. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/32
OWNER´S MANUAL
Outdoor siren BXA-8
(Art.nr 36-3817)
2012 07 19- -
SW1
Siren Learning
OFF
Normal operation
ON
Learn-in mode
SW2
Strobe Activation
OFF
On for alarm period
ON
On until reset
SW3
SW4
Siren Duration
OFF
OFF
3 min.
ON
OFF
5 min.
OFF
ON
10 min.
ON
ON
1 second (test)
SW5
OFF
Slave
ON
Stand alone-
SW6
Memory Reset
OFF
Normal
ON
Clear Memory
SW7
Reserved
GB W -8ireless Outdoor Bell Box, BXA
1. Mounting Holes x 4
2. Tamper Switch
3. Function Dip Switch Set
Contains 7 jumpers to enable the learning
mode and to set the alarm period of siren
and strobe light.
4. Securing Screw
To secure the case from opening
5. Power Switch
To enable/disable the power supply
6. LED
Accessories included
In addition to the Bell bo the following accessories are also included in the package:x itself,
a. 4 x large wall plugs.
b. 4 x 4mm x 30mm cross head fixing screws.
c. 4 x 1.5V D alkaline cells.
Dip Switch Table
Remove the cover by unscrewing the single screw located at the
bottom. In -the middle of the “L shaped” PCB board, you can see
a dip switch dip switches set which consists of 7 . The function of
each dip switch is listed as table below.
The DIP Switch is either ON or OFF. Top position indicates ON
and bottom position indicates OFF.
.
Power Supply
Bell box is powered by 4 D- cell alkaline batteries with life expectancy of over 3 years.
T he Bell box can detect if the battery is low. Low battery detection operates at a threshold of 4V +/- 10% where the Bell box
has enough power to typically operate for 1 month before complete exhaustion. The siren low battery signal will be
enunciated by five beeps when arming / disarming.
B ell Box Function Overview
Siren Memory Clear
The siren resets and clears all memory contents by a removal of the batteries. Wait for 1 minute and slide dip switch 6 to
ON position before re If dip switch 6 is turned OFF, - inserting the batteries. The siren will produce a short confirmation tone.
then siren ID code learned will reset every time when the siren has a power-up sequence.
ON
OFF
Siren Audible Performance
The siren produces a minimum of 104 dBA sound 3 and pressure at 1 meter on axis. It is programmable via two jumpers (SW
SW4) for four different siren durations:
1. 3 min.
2. 5 min.
3. 10 min.
4. 1 second
The fourth position (1 second) is used for testing during installation.
The siren is silenced when either the programmed siren duration expires or the Control panel turns off the siren.
In case of low battery condition, gives an intermittent alarm sound instead of continuous alarm sound during Bell box
the programmed siren duration.
For Burglar / Panic Alarm, Bell box gives a continuous alarm sound.
For Fire alarm, Bell box gives an intermittent alarm sound of 3 short beeps followed by a stop for 1.5 sec cyclically
during the programmed alarm duration.
For Water alarm, Bell box gives an intermittent alarm sound of a 50% duty cycle at 0.5 sec cyclically during the
programmed alarm duration.
Strobe Light
The strobe light will flash to indicate various system statuses and can be programmed by as shown in switch position SW2
table. It will be turned off either when the programmed siren duration has expired or the panel resets the system.
Tamper Alarm
If the siren detects a tamper condition it will activate the siren for the programmed alarm period. If the tamper condition
persists, the siren will sound a series of five pips either every time the system is armed or when the tamper is enabled, to
indicate a fault. Tamper feature can be enabled/disabled from the control unit by selecting “ menu, then “Device +/-
Program Siren” menu, and then, choose “Siren Tamp ON Siren Tamp OFF” or “ ” and press OK.
Confirm Programming
The siren can be programmed to produce additional confirmation beeps to tell you when the systems is armed and
disarmed from outside the premises. One beep for armed or home armed, two beeps for disarmed.
The setting up procedure can be done from the control panel underDevice +/- menu then “Program Siren menu and
select “Confirm On Confirm Off” or
Disable the Siren Confirmation by selecting “Confirmation Off and press “OK”.
Enable the Siren Confirmation by selecting “Confirmation On and press “OK.
Entry Sound On, Entry Sound Off
The Bell box can be enabled or disable from sounding the Entry Delay warning beeps. The setting up procedure can be done
from the control panel under “Program Siren” menu.
Disable the Siren Entry Sound by selecting Entry Snd Off” and press “OK”.
Enable the Siren Entry Sound by selecting “Entry Snd On and press “OK”.
Previous Alarm Warning
If there has been an alarm while you were away, the Bell box will sound and flash for 3 seconds when the system has been
disarmed.
WARNING: If the siren is activated for 3 seconds when you disarmed your system, this suggests that there could be an
intruder still in your premises.
Audio & Alarm Status Indication
Panic/Burglar: Continuous siren
Fire: Siren will be on (0.5s) & off (0.5s) for three times, then comes with a break of 1.5 sec.
Water: Siren will be on for 0.5s & off 0.5s continuously.
Audio & Visual Status Indication
In order to easily recognize various statuses, the
Bell box uses the following methods while you are
in the Arm and Disarm of the system to indicate the
user:
Siren Audio
Strobe light indication
Arm
1 beep *
3 LED flashes at once
Disarm
2 beep *
Sequentially flashes for 1 cycle
Arm (Low Battery)
5 beeps
3 LED flashes for three times
Disarm (Low Battery) 5 beeps Sequentially flashes for 2 cycles
Arm (Tamper) 5 beeps 3 LED flashes for three times
Disarm (Tamper)
2 beeps *
3 LED flashes for two times

Produktspecifikationer

Varumärke: Electia
Kategori: Larmsystem
Modell: BXA-8

Behöver du hjälp?

Om du behöver hjälp med Electia BXA-8 ställ en fråga nedan och andra användare kommer att svara dig




Larmsystem Electia Manualer

Larmsystem Manualer