Elektrobock PT10 Bruksanvisning

Läs nedan 📖 manual på svenska för Elektrobock PT10 (4 sidor) i kategorin Termostat. Denna guide var användbar för 11 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/4
ROOM THERMOSTAT
ELEKTROBOCK CZ s.r.o.
Blanenská 1763
Kuřim 664 34
Tel./fa x: +420 541 230 216
www.elbock.cz
Table for registration of your programs
1 2 3 4
Mon
Tue
Wed
Thu
Fri
Sat
Sun
day progr.
Temperature and time
set
CERTIFICATE OF GUARANTEE
(guarantee period for the product amounts to 2 years)
product No.: date of sale:
stamp of shop:
examined by:
MADE IN CZECH REPUBLIC
Send the controller for guarantee and after-guarantee service to distributor's address.
Specifications
Power supply alkal.batteries 2 x 1,5 V typ AA/R6
Number of adjustable temp. 4 temperature changes for a day
Hysteresis 0,5°C
Minimal programming time 30 minutes
Range of possible temp. 5 to 39°C
Step of temperature setting po 1°C
Minimal step of indication 0,1°C
Measurement accuracy 0,5°C
Output relay, max. 5A/250V AC
PT10 is a digital room thermostat for automatic regulation of heating, offering the possibility to set
4 temperature changes for each day (minimal duration of time interval to be set is 30 minutes).
Further advantages:
MAD E IN CZ ECH REPUBLIC
- different temperature program for each day
- simple control and programming
- possibility to make a short-term change in program
temperature
- easy installation to all types of installation boxes
KU/KP68
- retention of memory contents, when the batteries are
replaced sooner than after approx. 25s
Via digital regulation of temperature towards high
savings of energy
- FOR ALL TYPES OF HEATING
- 4 TEMPERATURE CHANGES IN A DAY
- ANTI-FREEZE TEMPERATURE OF 5°C
Overview of produced types:
Install the thermostat on a suitable place, where its operation would not be influenced by direct flow of hot air from
the heater, by solar radiation and other disturbing influences. Also avoid the installation on outer wall.
Follow the illustrations in the course of installation (Pic.1 to Pic.5):
INSTALLATION OF PT10:
Pic.1
Boiler
connection
Terminals 1 and 2
are interconnected
when the thermostat
is switched on
BOILER
ON
Pic.3
Pic.2
Pic.4 Pic.5
Openings for
mounting screws
(for KU/KP 68)
LOCATION OF BATTERIES AND THEIR REPLACEMENT: Pic.6
a, LOCATION OF BATTERIES (see Pic.6)
The batteries are located inside the front microprocessor part. After batteries insertion, colon must blink
on the LCD display. If some unidentifiable conditions occur, it is necessary to remove the batteries for
approx. 1 minute. Always observe correct polarity!
b, REPLACEMENT OF BATTERIES (serves also as a RESET of processor in undeterminable conditions).
Low battery is indicated by blinking symbol " " on the display. Use solely alkali pencil batteries bAtt
2x1.5 V of AA/R6 type! If the replacement lasts more than 25 s, all saved information will be lost!
in compliance with RoHS
LEAD FREE
60
The installation of PT10 may be performed only by a person with appropriate
qualification in electrical engineering.
PT10
PT1
PT1
PT1
PT10
0
0
0
PPb
ROOM THERMOSTAT
PT10
PT1
PT1
PT1
PT10
0
0
0
TS20
HD13-L
PT712
PT32GST
PT22
"TEST" FUNCTION: inspection of correct connection
By pressing and subsequently , the TEST function is activated.
This function performs switching-on and switching-off of the output contact for several times.
Fce
OPERATING INSTRUCTIONS
DISPLAY DESCRIPTION:
1
2
3
4
5
CONTROLS:
Fce : serves for function selection
: selection of set temperatures
i: information button (after pressing in AUTO mode it
displays successively required temperature,
current time/temperature and present day).
button for confirmation (ENTER)
+/- : for function selection and temperature setting
2, indication of selected function AUTO, MANU, PROG etc.
5, indication of time/temperature
4, indication of temperatures, comfort , economic
1, indication of set time and temperature program
3, indication of anti-freeze temperature
CLO FUNCTION: setting of current day and time
1, Press the button, by pressing select CLO (clock) function and confirm by .
2, The time is displayed and indication of hours is blinking on the display, use buttons to set
required hours and confirm by button. Indication of minutes starts blinking, use
buttons to set required minutes and confirm again by button. The day displays (d:1 repre
sents Monday, d:7 Sunday), use buttons to select current day and again confirm by
button. Press the button for comeback.
PAr FUNCTION : setting of parameters (constants)
1, Press the button, by pressing buttons select PAr (PARAMETERS) and confirm by .
PAr 1: display of current temperature (t) or time (C)
After displaying of Par1, press and with using of buttons select display option.
for displaying of current room temperature and confirm by button.
t
Cfor displaying of current time and again confirm by button.
PAr 2: setting of economic ( ) temperature
Press to set Par2, symbol displays. Set the value of economic temperature by
buttons and confirm it by pressing .
PAr 3: setting of comfort ( ) temperature
Press to set PAr3, symbol displays. Set the value of comfort temperature by
buttons and confirm it by pressing . Press the button for comeback.
PROG ” FUNCTION: setting the program for automatic mode AUTO
1, Press the button, by pressing buttons select PROG (programming)
and confirm by . The day to be programmed is showed on the display.
2, By pressing select the
days according to the table and
confirm by .
3, Symbol 1:U1 for the setting of the first time interval displays for a short time on the display. By pressing of
buttons set the time of the first change (min. step of 30 min.) and by means of pressing
the button assign economic or comfort temperature to this time. Again confirm by pressing
4, Symbol 1:U2 for the setting of the second time interval displays for a short time on the display. By pressing of
buttons set the time of the second change and by means of pressing the button assign
economic or comfort temperature to this time. Again confirm by pressing .
Use the same procedure for the setting of further time intervals and days.
Up to four time intervals (temperature changes) can be defined for one day.
Note: Last temperature set is maintained up to the first change of temperature of next day.
EXAMPLE:
1, Set 17°C for (Pa:r2)
2, Set 22°C for (Pa:r3)
3, Select programming of whole week d1:7 (Prog)
4, assign the time of 6:00 and temperature to 17:U1
5, assign the time of 09:00 and temperature to 17:U2
6, assign the time of 16:00 17:U3and temperature to
7, assign the time of 21:00 17:U4and temperature to
8, Leave the programming by pressing and select
AUTO function for setting the week program
setting of week program
When the output is switched on, AUTO/MANU is showed on the display, otherwise the symbol blinks.
Note: If you do not push any button in 2 minutes, PT10 returns into set mode. Longer pushing of
buttons speeds up their functions.
"PARTY" FUNCTION: short-term change of temperature in AUTO mode
By simple pressing of buttons in AUTO mode, it is possible to make a short-term change of required
temperature. PT10 will maintain this temperature up to next temperature change as defined in the program.
"OFF" FUNCTION: switching off of the thermostat
Press the button, by pressing of buttons select OF:F function and confirm by button.
In this way, PT10 is permanently switched off. In this mode, symbol OF:F and data on current temperature/time are showed
alternatively on the display. To cancel this function, press button and select different mode with using of buttons.
FUNCTION: anti-freeze temperature in OFF mode
If in the "OFF" mode, the room temperature drops below 5° C, the thermostat automatically switches on the output and symbol
" " is displayed. In this way, PT10 prevents freezing up of the heating system.
FUNCTIONS OF PT10:
Following functions can be selected by pressing and then buttons:
1. AUTO : the thermostat works according to program as set.
2. MANU : serves for manual setting of temp. ( the selection by or buttons), the
temperature should be constant up to next change.
3. CLO : setting of present day and time.
4. PAr : setting of parameters (constants).
5. PROG : programming mode.
6. OFF : in this mode, PT10 is permanently switched-off (with the exception of the regime ).
Fce
Fce i
i
i
i
Fce i
Fce
i
i
i
i
i
i
i
i
i
i
i
Fce i
Fce
d:1 Mon
d:2 Thu
d:3 Wed
d:4 Thur
d1:5 Mon to Fri
d6:7 Sat to Sun
d1:7 whole week
d:5 Fri
d:6 Sat
d:7 Sun
TABLE: SELECTION OF DAYS FOR PROGRAMMING
Fce
Fce
Fce
"LOCK" FUNCTION:
By simultaneous pressing of , and buttons the keyboard is locked (buttons are inactive).
Message LOC (LOCK) is shortly displayed. The function can be cancelled, e.g. the keyboard unblocked by
simultaneous pressing of , and buttons (the buttons are again functioning from now).
child lock (protection against unauthorized handling)
Fce
Fce

Produktspecifikationer

Varumärke: Elektrobock
Kategori: Termostat
Modell: PT10

Behöver du hjälp?

Om du behöver hjälp med Elektrobock PT10 ställ en fråga nedan och andra användare kommer att svara dig




Termostat Elektrobock Manualer

Termostat Manualer

Nyaste Termostat Manualer