Elkay LK4590FR Bruksanvisning
Elkay
Vattendispenser
LK4590FR
Läs nedan 📖 manual på svenska för Elkay LK4590FR (12 sidor) i kategorin Vattendispenser. Denna guide var användbar för 11 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/12
96812C (Rev. SID - 1/11)
4590FR_FTN LK4590FR_FTN LK4590SFR_FTN
Owners Manual
4590 Freeze Resistant Barrier Free Stone Pedestal Fountain
4590 Fountains are among the easiest to install Fountains on the market today. To assure you
install these models easily and correctly, PLEASE READ THESE SIMPLE INSTRUCTIONS
BEFORE STARTING THE INSTALLATION. CHECK YOUR INSTALLATION FOR COMPLIANCE
WITH PLUMBING, ELECTRICAL, AND OTHER APPLICABLE CODES. After installation, leave
these instructions with the Fountain for future reference.
IMPORTANT
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON
IMPORTANT
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO WATER LINES IS A
COMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY OCCUR AWAY FROM THE BUILDING. THIS
GROUNDING CAN CAUSE ELECTRICAL FEEDBACK INTO A FOUNTAIN, CREATING AN ELECTROLYSIS WHICH CAUSES A
METALLIC TASTE OR AN INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION IS AVOIDABLE BY USING
THE PROPER MATERIALS AS INDICATED. ANY DRAIN FITTINGS PROVIDED BY THE INSTALLER SHOULD BE MADE OF
PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING PLUMBING SYSTEM.
INSTALLER
STOP!
PLEASE READ THE FOLLOWING
INFORMATION.
• INSTALLATION INSTRUCTIONS FOR THE 4590FR FTN.
WITH 97243C SINGLE VALVE CONTROL ASSEMBLY ARE
LOCATED ON PAGES 2 - 5.
• INSTALLATION INSTRUCTIONS FOR THE 4590FR FTN.
WITH SANITARYFR1 VALVE ARE LOCATED ON PAGES
6 - 12.
PAGE 296812C (Rev. SID - 1/11)
4590FR_FTN LK4590FR_FTN LK4590SFR_FTN
Owners Manual
4590 Freeze Resistant Floor Mounted Barrier Free Stone Fountain
with 97243C Single Valve Control Assembly
IMPORTANT! INSTALLER PLEASE NOTE
Do not pull up on lines coming out of the PVC column. This raises the water valve above the frost line with
disastrous results.
General Installation Tips
1. Be sure to flush water supply line before you connect it to the inlet fitting on Freeze Resistant Valve System.
2. There are two drain lines required for this unit. One for the drinking fountain basin drain and one for the valve/water supply line system. The bowl drain is the 3/4"
PVC fitting at the bottom of the 6" PVC tube and the valve drains through the small holes in the PVC cap. Provide ample drainage for these two items. It's always
better to have too much then not enough.
3. The column (6" PVC tube) must remain vertical. Be sure it remains vertical when backfilling the excavating trench.
4. When the concrete pad, for mounting the fountain, is poured, be sure to allow adequate space around the top of the column so that the flexible cap may be
removed for servicing the valve.
5. We recommend that the top of the column be flush or slightly above the top height of the concrete pad.
6. You should test the unit before you backfill. Simply blow on the clear, small diameter tubing. A steady stream should flow from the braided tubing line. When air
pressure is removed from the clear tubing the water stream should stop.
7. Once you have tested the valve, backfilled the hole and poured the concrete mounting pad you are ready to set the fountain. After bolting the fountain in place
connect the air control valve tubing, supply water tubing and drain lines. The water supply line must have a straight run from the basin bubbler down to the control
valve. If a straight run is not maintained water will become trapped and freeze leaving the unit inoperable. Test the fountain again. If it fails to work, the air
control line may be kinked or connected improperly. Be sure to keep water out of the air control line.
8. These products are designed to operate on 20 psig to 105 psig supply line pressure. If inlet pressure above 105 psig, a pressure regulator must be installed in the
supply line. Any damage caused by reason of connecting this product to supply line pressure lower than 20 psig or higher than 105 psig is not covered by
warranty.
PAGE 3 96812C (Rev. SID - 1/11)
4590FR_FTN LK4590FR_FTN LK4590SFR_FTN
LEGEND
A = ACCESS PANEL
B = REMOVABLE BOTTOM COVER
C = 1" PVC DRAIN
D = PRESSURE FITTING 1-1/4" x 3/4"
E = CONNECTOR 1-1/4" TO 1-1/4"
F = 1-1/4" DRAIN TUBE
G = AIR CONTROL LINE
H = 1/4" WATER LINE
J = CONNECTOR FOR AIR CONTROL LINE
SITE PREPARATION DETAIL FOR THE
4590FR FTN. WHEN USING 97243C SINGLE VALVE CONTROL ASSY.
FIG. 1
Produktspecifikationer
Varumärke: | Elkay |
Kategori: | Vattendispenser |
Modell: | LK4590FR |
Behöver du hjälp?
Om du behöver hjälp med Elkay LK4590FR ställ en fråga nedan och andra användare kommer att svara dig
Vattendispenser Elkay Manualer
1 Oktober 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
Vattendispenser Manualer
- Vattendispenser Philips
- Vattendispenser Panasonic
- Vattendispenser Honeywell
- Vattendispenser Bartscher
- Vattendispenser Orbegozo
- Vattendispenser Princess
- Vattendispenser Omega
- Vattendispenser Hitachi
- Vattendispenser Korona
- Vattendispenser Hoover
- Vattendispenser Breville
- Vattendispenser Waring Commercial
- Vattendispenser Avanti
- Vattendispenser Westinghouse
- Vattendispenser Midea
- Vattendispenser Avalon
- Vattendispenser Igloo
- Vattendispenser Haier
- Vattendispenser Elba
- Vattendispenser Nutrichef
- Vattendispenser Oasis
- Vattendispenser Bunn
- Vattendispenser Franke
- Vattendispenser Caso
- Vattendispenser NewAir
- Vattendispenser Fetco
- Vattendispenser SPT
- Vattendispenser Crathco
- Vattendispenser Waterdrop
- Vattendispenser Hiberg
- Vattendispenser Cal-Mil
- Vattendispenser Primo Water
- Vattendispenser Perlick
- Vattendispenser Brentwood
- Vattendispenser Healthy Choice
- Vattendispenser SodaKING
- Vattendispenser BIBO
- Vattendispenser Imarflex
Nyaste Vattendispenser Manualer
15 Oktober 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
25 September 2024