Elro FC280211 Bruksanvisning
Elro
Brandsläckare
FC280211
Läs nedan 📖 manual på svenska för Elro FC280211 (33 sidor) i kategorin Brandsläckare. Denna guide var användbar för 11 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/33
FC28 Manual Version 30211
MANUAL
CARBON MONOXIDE DETECTOR
10 YEARS CO SENSOR
Home is not a place, it’s a feeling
FC280211
English Manual Page 1 - 0 07
Deutsche Bedienungsanleitung Seite - 08 15
Nederlands Gebruiksaanwijzing Bladzijde - 16 23
Français Manuel d'utilisation Page - 24 31
- -1
Thank you for purchasing the FC280211 carbon monoxide (CO) alarm.
This unit uses advanced electrochemical sensor, and with LCD digital display for CO concentration. Please take a few minutes to
thoroughly read the user manual before operating or servicing and familiarize yourself and your family with its operation. And
save for future reference.
• Reliable electrochemical sensor
• Including 2x 1,5V batteries
• Silence mode
• Low-battery indicator
• End- -life indicator of
The alarm should be installed by a competent person. This apparatus is designed to protect individuals from the acute effects
of carbon monoxide exposure. It will not fully safeguard individuals with specific medical conditions. If in doubt consult a
medical practitioner.
CAUTION: This CO alarm is designed for indoor use only. Do not expose to rain or moisture. Do not knock or drop the detector.
Do not open or tamper with the alarm as this could cause malfunction. The alarm will not protect against the risk of carbon
monoxide poisoning when the battery has drained. Installation of the alarm should not be used as a substitute for proper
installation, use and maintenance of fuel burning appliances including appropriate ventilation and exhaust systems.
WARNING! - Do NOT try to repair the device, it has the risk of electric shock or malfunction if the device is tampered with.
We are constantly improving our products and service. Go to to download the latest version of this manual! www.elro.eu
Also check for all relevant frequently asked questions and newest developments for this product. This will help www.elro.eu
you to better understand the product.
1. INSTALLATION INSTRUCTIONS
1.1 Installation location
When choosing your installation locations, make sure you can hear the alarm from all sleeping areas. If you install
only one CO alarm in your home, install the alarm near bedrooms. Not in the basement or furnace room. The
recommended position for the unit should be at least 1.8 meters (about 6 feet) above the floor level.
CAUTION: This alarm should be installed by a competent person.
1.2 Mounting step
• Drilling two ф5.0mm holes in the wall, the distance between two holes center is 52mm, then inserting two plastic
plugs provided into the holes.
• Insert the two screws provided until the screw heads are approximately 5mm from wall.
• Test the unit by using the TEST/SILENCE button. Ensure the unit sound is alarm pattern.
• Hook the unit over the screws onto keyholes at the back of the unit.
- -2
1.3 Recommended installation locations
The following suggestions are intended to help you with the placement and installation of your CO alarm.
• Place out of the reach of children. Under no circumstance should children be allowed to handle the CO alarm.
• Install in a bedroom or hallway located close to the sleeping area. Take special care to verify the alarm can be heard
in sleeping areas.
• It is recommended that a CO alarm be installed on each level of a multilevel home.
• Locate 1~3 meter (3.3~10feet) away from all fuel burning appliances.
• Placing at eye level allows for optimum monitoring of the red and green indicator lights.
• Ensure that all vents of the unit are unobstructed.
• Do not install in dead air spaces such as peaks of vaulted ceilings, or gabled roofs.
• Do not install in turbulent air from ceiling fans.
• Do not place near fresh air vents or close to doors and windows that open to the outside.
• Keep the CO alarm away from excessively dusty, dirty, or greasy areas such as kitchens, garages, and furnace rooms.
• Dust, grease, and household chemicals can affect the sensor.
• Keep out of damp and humid areas such as the bathroom.
• Avoid spraying aerosols near the CO alarm.
• Do not install in areas where the temperature is below -10°C or hotter than 45°C.
• Do not place behind curtains or furniture. CO must be able to reach the sensor for the unit to accurately detect CO.
2. PRODUCT OVERVIEW
2.1 FAULT indicator
The FAULT indicator (yellow LED) is used to indicate fault or warning status of the CO alarm.
2.2 POWER indicator
The POWER indicator (green LED) is used to indicate power status of the CO alarm. The POWER indicator will flash
every 40 seconds.
2.3 ALARM indicator
The ALARM indicator (red LED) is used to indicate alarm status of the CO alarm.
2.4 TEST/SILENCE button
The TEST/SILECNE button is used to test the unit. Press and hold to enable TEST function.
2.5 Alarm sounder
The alarm sounder is used to send out CO alarm warning and fault warning information.
2.6 LCD screen
Indicates CO concentration and alarm status.
If CO concentration overruns 20PPM, the function of temperature display will be disable.
Produktspecifikationer
Varumärke: | Elro |
Kategori: | Brandsläckare |
Modell: | FC280211 |
Behöver du hjälp?
Om du behöver hjälp med Elro FC280211 ställ en fråga nedan och andra användare kommer att svara dig
Brandsläckare Elro Manualer
7 Oktober 2024
28 September 2024
17 September 2024
14 September 2024
3 September 2024
19 Augusti 2024
Brandsläckare Manualer
- Brandsläckare Alecto
- Brandsläckare Smartwares
- Brandsläckare Malmbergs
- Brandsläckare First Alert
- Brandsläckare Gloria
- Brandsläckare Deltronic
Nyaste Brandsläckare Manualer
13 Oktober 2024
23 September 2024
18 September 2024
18 September 2024
17 September 2024
17 September 2024
17 September 2024
18 Augusti 2024
30 Juli 2024
29 Juli 2024