EMOS P5525 Bruksanvisning
EMOS
Digital tidbrytare
P5525
Läs nedan 📖 manual på svenska för EMOS P5525 (48 sidor) i kategorin Digital tidbrytare. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/48
1927110020_31-P5525_00_01_WEB 105 × 148 mm
P5525
GB Digital Timer Socket
DE Digitale Zeitschaltuhr
HU Digitális időkapcsoló aljzat
SI Digitalna stikalna ura
RS|HR|BA|ME Utičnica s digitalnim timerom
UA Розетка цифрового таймера
RO|MD Priză cu temporizator digital
LT Skaitmeninio laikmačio lizdas
LV Digitālā taimera ligzda
EE Digitaalse taimeriga pistikupesa
BG Гнездо с дигитален таймер
IT Spina temporizzata digitale
ES Enchufe con interruptor digital
NL Digitaal schakelstopcontact
www.emos.eu
2
GB | Digital Timer Socket
Specications
Power supply: 230 V~, 50 Hz, 16(2) A
Max. load: 3 680 W
IP rating: IP44
Operating temperature: -10 °C to +40 °C
increment for setting time: 1 minute
16 combinations of days or blocks of days
Deviation: ±1 minute a month
Switched phase
Back-up battery: NiMH 1.2 V >100 hours
Features
1. The digital timer socket can be used to preset a specic time to turn your appliances on or o out-
doors or in your household. It is ideal for saving energy and improving the safety of your household.
2. The random on/o feature allows you to turn appliances on or o at irregular times, making
it ideal not only for certain automatic functions in your household, but also for protecting you
against break-ins during your absence.
3. The LCD screen shows the programme settings and real time.
4. You can set up to 10 programmes for activating/deactivating the socket.
Installation
1. Plug the timer socket into a 230 V AC socket.
2. Let it charge for approx. 12 hours.
3. Once the socket is charged, erase all stored information by pressing the MASTER CLEAR button
using a sharp object such as a pencil or pen.
4. The timer socket is now ready for setting and use.
Time Display
Time can be displayed in two dierent ways.
1. 12-hour time display: digital display of time from 00:00 to 11:59, with the screen showing AM
(from midnight to noon) or PM (from noon to midnight).
2. 24-hour time display: digital display of time from 00:00 to 23:59, with no AM or PM on the screen.
3. To switch between the two time display modes, press the CLOCK and TIMER buttons simul-
taneously.
Setting the Day of the Week and Time
1. Setting the Day of the Week
1.1 Press and hold down the CLOCK button and press the WEEK to set the day of the week.
1.2 The order of the days is displayed as follows:
Mo Tu We Th Fr Sa Su
Mo = Monday, Tu = Tuesday , We = Wednesday, Th = Thursday, Fr = Friday, Sa = Saturday, Su = Sunday
1.3 If you hold down the CLOCK button and simultaneously press the WEEK button once, the days are
displayed in order slowly. If you press and hold down both buttons, the days in the week will change
more rapidly. Release the buttons once the day of the week of choice appears on the screen.
2. Setting Time
2.1 To set the time, press and hold down the CLOCK button and press the HOUR button.
2.2 If you hold down the CLOCK button and press the HOUR button once, the time changes slowly.
If you hold down both buttons at the same time, the time changes more rapidly. Release the
buttons once the time of choice appears on the screen.
2.3 To set the minutes, press and hold down the CLOCK button and press the MINUTE button. Set
the minutes the same way you did hours, as described in point 2.2.
3. Setting Daylight Saving Time
3
3.1 Press and hold down the CLOCK button and press the ON/AUTO/OFF to switch to daylight saving
time. The time on the screen will automatically shift forward one hour and the letter S will
appear on the screen.
3.2 Pressing the CLOCK and ON/AUTO/OFF buttons again cancels daylight saving time, the time shifts
back one hour and the letter S disappears.
Note: To set the day of the week and time, the LCD screen must be in real time display mode. If the
LCD screen is in programme setting mode, press the CLOCK to return to real time display mode.
Programme Settings
1. If the LCD is displaying real time (CLOCK is on the screen), press the TIMER button once to switch
to programme setting mode; 1ON will appear on the left side of the screen and the screen will
show the word PROGRAM.
1.1 “1” indicates the number of the programme group (programme group numbers range from 1 to 10).
1.2 “ON” indicates turning the socket on.
1.3 “OFF” indicates turning the socket o.
2. To select a programme group and choose between the on/o state, press the TIMER button to
increase the programme group number. The order is as follows:
N 1O 1OFF 2ON 2OFF …… 10ON 10OFF
Real time will be displayed automatically after 30 s of inactivity in settings or if you press the CLOCK
button.
3. After selecting a programme (1–10), you can set the day of the week and the time. Press
the WEEK button to select the day or block of days in the week. The days/blocks of days are
displayed in this order:
3.1 MO->TU->WE->TH->FR->SA->SU
3.2 MO TU WE TH FR SA SU
3.3 MO TU WE TH FR
3.4 SA SU
3.5 MO TU WE TH FR SA
3.6 MO WE FR
3.7 TU TH SA
3.8 MO TU WE
3.9 TH FR SA
3.10 MO WE FR SU
4. To set the programme time, the LCD screen must show the word PROGRAM.
4.1 To set the hour when the programme should turn on (1ON), press the HOUR button once to slowly
set the hour value. If you hold down the button, the value changes more rapidly. Release the
button once the time of choice in hours appears on the screen.
4.2 To set the minutes when the programme should turn on (1ON), press the MINUTE button once
to slowly set the minute value. If you hold down the button, the value changes more rapidly.
Release the button once the time of choice in minutes appears on the screen.
4.3 To set the end of the programme (1OFF), press the TIMER button and set the time as described
in points 4.1 and 4.2
Note:
(a) If you wish to change a previously set programme, proceed as described in points 4 to 4.3 in
section F and enter new values to overwrite the previous settings.
(b) Once a programme is set, press the CLOCK button to immediately return to real time display. If
you don’t, real time will be displayed automatically after 30 seconds of inactivity.
Random Setting
1. The random setting feature turns the connected appliance on and o irregularly at a 10 to 31
minute interval from 18:00 to 6:00.
2. Plug the timer socket into a mains socket and set the programme using the ON/AUTO/OFF button
to AUTO so that you can start/end the random function.
3. Press the RANDOM button once; the letter R will light up on the right of the screen and the random
function is now active. The socket will be o for 10 to 31 minutes. After that, the function will
switch to the opposite mode, i.e. on.
Produktspecifikationer
Varumärke: | EMOS |
Kategori: | Digital tidbrytare |
Modell: | P5525 |
Behöver du hjälp?
Om du behöver hjälp med EMOS P5525 ställ en fråga nedan och andra användare kommer att svara dig
Digital tidbrytare EMOS Manualer
15 December 2024
15 December 2024
15 December 2024
Digital tidbrytare Manualer
- Digital tidbrytare Theben
- Digital tidbrytare Hager
- Digital tidbrytare Sencys (Praxis)
- Digital tidbrytare PROmax
Nyaste Digital tidbrytare Manualer
13 December 2024
12 December 2024
14 September 2024
14 September 2024
10 September 2024
30 Augusti 2024
27 Augusti 2024