User's Guide
Mini Multimeter
with Non-Contact Voltage Detector (NCV)
Model EX320
EX320-en-GB_V5.5 4/15 2
Introduction
Congratulations on your purchase of the Extech EX320 Meter. The EX320 offers AC/DC Voltage,
AC/DC Current, Resistance, Diode, Continuity, non-contact Voltage Detection. Proper use and care of
this meter will provide many years of reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds 600V.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
This symbol indicates that a device is protected throughout by double insulation or
reinforced insulation.
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules listed
below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Protection Limits
Function Maximum Input
V DC or V AC 600V AC and DC
mA AC/DC 500mA DC/AC
A AC/DC 10A DC/AC (for 30 seconds max. every 15
minutes
Resistance, Diode Test, Continuity 250V DC/AC
Temperature 250V DC/AC
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 600V above earth
ground.
4. NEVER connect the meter leads across a voltage source while the function switch is in the
current, resistance, or diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making
resistance or diode tests.
6. ALWAYS turn off power and disconnect test leads before opening the covers to replace the fuse
or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse covers are in place
and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
WARNING
CAUTION
MAX
600V
EX320-en-GB_V5.5 4/15 3
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and understand
this user manual before operating the meter.
Always remove the test leads before replacing the battery or fuses.
Inspect the condition of the test leads and the meter itself for any damage before operating the
meter.
Use great care when making measurements if the voltages are greater than 25VAC rms or
35VDC. These voltages are considered a shock hazard.
Warning! This is a class A equipment. This erences in the living equipment can cause interf
quarters; in this case the operator can be required to carry out adequate measures.
Always discharge capacitors and remove power from the device under test before performing
Diode, Resistance or Continuity tests.
Voltage checks on electrical outlets can be difficult and misleading because of the uncertainty
of connection to the recessed electrical contacts. Other means should be used to ensure that
the terminals are not "live".
If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
This device is not a toy and must not reach children’s hands. It contains hazardous objects as
well as small parts that the children could swallow. In case a child swallows any of them,
please contact a physician immediately
Do not leave batteries and packing material lying around unattended; they can be dangerous
for children if they use them as toys
In case the device is going to be unused for an extended period of time, remove the batteries
to prevent them from training
Expired or damaged batteries can cause cauterization on contact with the skin. Always,
therefore, use suitable hand gloves in such cases
See that the batteries are not short-circuited. Do not throw batteries into the fire.

Produktspecifikationer

Varumärke: Extech
Kategori: Multimeter
Modell: EX320

Behöver du hjälp?

Om du behöver hjälp med Extech EX320 ställ en fråga nedan och andra användare kommer att svara dig




Multimeter Extech Manualer

Extech

Extech DM220 Bruksanvisning

19 September 2024
Extech

Extech MA440 Bruksanvisning

16 September 2024
Extech

Extech EX355 Bruksanvisning

16 September 2024
Extech

Extech EX623 Bruksanvisning

16 September 2024
Extech

Extech MA443 Bruksanvisning

16 September 2024
Extech

Extech EX320 Bruksanvisning

24 Augusti 2024
Extech

Extech MN36 Bruksanvisning

19 Augusti 2024
Extech

Extech DM110 Bruksanvisning

15 Augusti 2024
Extech

Extech EX540 Bruksanvisning

15 Augusti 2024

Multimeter Manualer

Nyaste Multimeter Manualer