User's Guide
400Amp True RMS AC/DC Clamp
Meter with IR Thermometer
Model EX623
EX623-EU V2.3 04/10 2
Introduction
Congratulations on your purchase of this Extech EX623 True RMS Clamp Meter. This meter
measures AC Current, DC Current, AC/DC Voltage, Resistance, Capacitance, Frequency,
Diode Test, Duty Cycle and Continuity. Special features include Dual Input Thermocouple
Temperature, Non-Contact IR Temperature and Non-Contact Voltage detector. The double
molded case is designed for heavy duty use. This meter is shipped fully tested and calibrated
and, with proper use, will provide years of reliable service.
Safety
International Safety Symbols
This symbol, adjacent to another symbol or terminal, indicates the user
must refer to the manual for further information.
This symbol, adjacent to a terminal, indicates that, under normal use,
hazardous voltages may be present
Double insulation
This WARNING symbol indicates a potentially hazardous situation, which
if not avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which
if not avoided, may result damage to the product.
PER IEC1010 OVERVOLTAGE INSTALLATION CATEGORY
OVERVOLTAGE CATEGORY I
Equipment of OVERVOLTAGE CATEGORY I is equipment for connection to circuits in
which measures are taken to limit the transient overvoltages to an appropriate low level.
Note – Examples include protected electronic circuits.
OVERVOLTAGE CATEGORY II
Equipment of OVERVOLTAGE CATEGORY II is energy-consuming equipment to be
supplied from the fixed installation.
Note – Examples include household, office, and laboratory appliances.
OVERVOLTAGE CATEGORY III
Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations.
Note – Examples include switches in the fixed installation and some equipment for industrial
use with permanent connection to the fixed installation.
OVERVOLTAGE CATEGORY IV
Equipment of OVERVOLTAGE CATEGORY IV is for use at the origin of the installation.
Note – Examples include electricity meters and primary over-current protection equipment
WARNING
CAUTION
EX623-EU V2.3 04/10 3
SAFETY NOTES
Do not exceed the maximum allowable input range of any function.
Do not apply voltage to meter when resistance function is selected.
Set the function switch OFF when the meter is not in use.
Remove the battery if meter is to be stored for longer than 60 days.
WARNINGS
Set function switch to the appropriate position before measuring.
When measuring volts do not switch to current/resistance modes.
Do not measure current on a circuit whose voltage exceeds 600V.
When changing ranges always disconnect the test leads from the circuit under test.
CAUTIONS
Improper use of this meter can cause damage, shock, injury or death. Read and
understand this user manual before operating the meter.
Always remove the test leads before replacing the battery or fuses.
Inspect the condition of the test leads and the meter itself for any damage before
operating the meter. Repair or replace any damage before use.
Use great care when making measurements if the voltages are greater than 25VAC
rms or 35VDC. These voltages are considered a shock hazard.
Always discharge capacitors and remove power from the device under test before
performing Diode, Resistance or Continuity tests.
Voltage checks on electrical outlets can be difficult and misleading because of the
uncertainty of connection to the recessed electrical contacts. Other means should be
used to ensure that the terminals are not "live".
If the equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
This device is not a toy and must not reach children’s hands. It contains hazardous
objects as well as small parts that the children could swallow. In case a child
swallows any of them, please contact a physician immediately
Do not leave batteries and packing material lying around unattended; they can be
dangerous for children if they use them as toys
In case the device is going to be unused for an extended period of time, remove the
batteries to prevent them from draining
Expired or damaged batteries can cause cauterization on contact with the skin.
Always, therefore, use suitable hand gloves in such cases
See that the batteries are not short-circuited. Do not throw batteries into the fire.
Do not directly view or direct the laser pointer at an eye. Low power visible lasers
do not normally present a hazard, but may present some potential for hazard if
viewed directly for extended periods of time
Function Maximum Input
A AC, 400A DC/AC
A DC 400A DC/AC
V DC, V AC 600V DC/AC
Resistance, Capacitance, Frequency, Diode Test 250V DC/AC
μA 4000 μA
Type K Temperature 30V DC, 24V AC

Produktspecifikationer

Varumärke: Extech
Kategori: Multimeter
Modell: EX623

Behöver du hjälp?

Om du behöver hjälp med Extech EX623 ställ en fråga nedan och andra användare kommer att svara dig




Multimeter Extech Manualer

Extech

Extech DM220 Bruksanvisning

19 September 2024
Extech

Extech MA440 Bruksanvisning

16 September 2024
Extech

Extech EX355 Bruksanvisning

16 September 2024
Extech

Extech EX623 Bruksanvisning

16 September 2024
Extech

Extech MA443 Bruksanvisning

16 September 2024
Extech

Extech EX320 Bruksanvisning

24 Augusti 2024
Extech

Extech MN36 Bruksanvisning

19 Augusti 2024
Extech

Extech DM110 Bruksanvisning

15 Augusti 2024
Extech

Extech EX540 Bruksanvisning

15 Augusti 2024

Multimeter Manualer

Nyaste Multimeter Manualer