Extech MG310 Bruksanvisning
Extech
Multimeter
MG310
Läs nedan 📖 manual på svenska för Extech MG310 (12 sidor) i kategorin Multimeter. Denna guide var användbar för 11 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/12
USER MANUAL
Insulation Resistance Tester
WithContinuityandACVoltagemodes
ModelMG310
2 MG310-en-GB_V1.0 12/15
Introduction
Thank you forselectingtheMG310InsulationResistanceTester.Thismetermeasuresinsulation
resistance,continuity,and andAC III AC Voltage. TheMG310isCAT 600V idealformeasuring
insulatingmaterialsand andelectrical asequipmentsuch transformers,cables,switches,
appliances.Applications testing, inspection.includemaintenance, and Properuseandcare thisof
meterwillprovidemanyyearsofreliableservice.
Safety
This Thistesteris indesignedandmanufactured compliancewiththeIEC61010standard. user
manual andincludesdetailedinformationrelatedtothesafeoperation careofthisinstrument.
Pleasereadcarefullybeforeusingtheinstrument.
Please read and understand this user manual before using the device.
Always use the device as specified in the user manual, retain the manual for future use and
checkthewww.extech.com website for newer versions of the user manual.
Misuse of this device may cause personal injury and damage to the instrument and
connectedequipment.
This symbol on the instrument indicates that for safe operation the user must use the
instrumentasdescribedintheuser manual.
Dangericons:Alerttoconditionsandactionsthatmaycauseseriousorfatalinjury.
Warningicons: Alert the user to the potential of electric shock.
Cautionicons:Alerttoconditionsandactionsthatmaycausedamagetotheinstrumentor
thatmayaffecttheinstrumentaccuracy.
Danger
Do not measure circuits with voltages greater than 750V AC.
Do not use this instrument in areas where flammable conditions exist.
Do not use this instrument in areas of high humidity. Do not operate this instrument with
wethands.
Do not touch conductive sections of the test leads when taking measurements.
When test leads are shorted and connected to the instruments do not press the TEST button.
Do not open the battery cover during tests.
Do not touch the tested circuits or wires during insulation measurements.
3 MG310-en-GB_V1.0 12/15
Warning
If the instrument exhibits faulty operation please discontinue use and have the instrument
serviced.
Be extremely careful when the instruments is measuring voltages that exceed 33V AC rms,
46.7VACrms,or70VDC;electricalshockispossible.
When high resistance measurements are conducted, stray electrical in circuits under test
mustbedischarged.
Do not replace the batteries when the instrument is wet.
Ensure secure connections with the test leads and the instrument’s test lead terminals.
Shut the instrument down before opening the battery compartment.
Caution
Circuits under test must be completely discharged and isolated from power circuits before
takingresistancemeasurements.
If the test leads or adaptors need to be replaced due to damage, replace with test leads or
adaptors theof samemodelorelectricalspecifications.
Do not use the instrument if low battery indicator shows the low battery indicator. If the
instrument not safely.will beusedfor a long storeperiod,pleaseremove batterythe and
Do not store or operate the instrument in areas of high temperature, high humidity, flame or
explosivepotentials,orwherestrongelectromagnetic fields exist.
Clean the instrument housing with a damp cloth and mild cleaning agent; do not use
abrasivesor solvents.
If the instrument is wet, please dry before storing.
ElectricalSafetySymbols
Riskofelectrical shock
Doubleinsulationor reinforced insulation
ACMeasurement
Ground
Produktspecifikationer
Varumärke: | Extech |
Kategori: | Multimeter |
Modell: | MG310 |
Behöver du hjälp?
Om du behöver hjälp med Extech MG310 ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Extech Manualer
23 December 2024
19 September 2024
16 September 2024
16 September 2024
16 September 2024
16 September 2024
11 September 2024
6 September 2024
3 September 2024
2 September 2024
Multimeter Manualer
- Multimeter Abus
- Multimeter Alecto
- Multimeter Appa
- Multimeter Amprobe
- Multimeter Amiko
- Multimeter Silverline
- Multimeter Ferm
- Multimeter Workzone
- Multimeter Yato
- Multimeter Milwaukee
- Multimeter Elro
- Multimeter EMOS
- Multimeter Tacklife
- Multimeter Schneider
- Multimeter Metrix
- Multimeter Benning
- Multimeter Voltcraft
- Multimeter Somogyi
- Multimeter Velleman
- Multimeter Steren
- Multimeter Kyoritsu
- Multimeter Ideal
- Multimeter Flir
- Multimeter Maxwell
- Multimeter Digitus
- Multimeter Testboy
- Multimeter Hager
- Multimeter TFA
- Multimeter Clas Ohlson
- Multimeter Powerfix
- Multimeter Owon
- Multimeter Fluke
- Multimeter Basetech
- Multimeter Etekcity
- Multimeter Greenlee
- Multimeter Högert
- Multimeter REV
- Multimeter Testo
- Multimeter Keithley
- Multimeter Monacor
- Multimeter Metrel
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Brandson
- Multimeter GW Instek
- Multimeter Skandia
- Multimeter Elma
- Multimeter Testec
- Multimeter Beha-Amprobe
- Multimeter Vimar
- Multimeter Uni-T
- Multimeter Kewtech
- Multimeter Strex
- Multimeter Mastech
- Multimeter PeakTech
- Multimeter Sonel
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Gossen Metrawatt
- Multimeter Rigol
- Multimeter PCE Instruments
- Multimeter Micronta
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Joy-it
- Multimeter Klein Tools
- Multimeter Aim TTi
- Multimeter Kurth Electronic
- Multimeter Wiha
- Multimeter IWH
- Multimeter Weltron
- Multimeter Sanwa
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nyaste Multimeter Manualer
8 Januari 2025
3 Januari 2025
1 Januari 2025
29 December 2024
29 December 2024
29 December 2024
29 December 2024
28 December 2024
22 December 2024
19 December 2024