User's Guide
Digital Multimeter
Model MN42
MN42-en-GB_v1.3 04/15
2
Introduction
Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage,
DC Current, and Resistance testing. Proper use and care of this meter will provide many years of
reliable service.
Safety
This symbol adjacent to another symbol, terminal or operating device indicates
that the operator must refer to an explanation in the Operating Instructions to
avoid personal injury or damage to the meter.
This WARNING symbol indicates a potentially hazardous situation, which if not
avoided, could result in death or serious injury.
This CAUTION symbol indicates a potentially hazardous situation, which if not
avoided, may result damage to the product.
This symbol advises the user that the terminal(s) so marked must not be
connected to a circuit point at which the voltage with respect to earth ground
exceeds 600VAC or VDC.
This symbol adjacent to one or more terminals identifies them as being associated
with ranges that may, in normal use, be subjected to particularly hazardous
voltages. For maximum safety, the meter and its test leads should not be handled
when these terminals are energized.
This symbol indicates that a device is protected throughout by double insulation or
reinforced insulation.
SAFETY INSTRUCTIONS
This meter has been designed for safe use, but must be operated with caution. The rules listed
below must be carefully followed for safe operation.
1. NEVER apply voltage or current to the meter that exceeds the specified maximum:
Input Protection Limits
Function Maximum Input
V DC or V AC 600V AC and DC 200Vrms on the 200mV range
mA DC 200mA DC 250V fast acting fuse
ADC 10A 250V fast acting fuse
(30 seconds max every 15 minutes)
Resistance, Continuity 250Vrms 15 seconds max
2. USE EXTREME CAUTION when working with high voltages.
3. DO NOT measure voltage if the voltage on the "COM" input jack exceeds 500V above earth
ground.
4. NEVER connect the meter leads across a voltage source while the function switch is in the
current, resistance, or diode mode. Doing so can damage the meter.
5. ALWAYS discharge filter capacitors in power supplies and disconnect the power when making
resistance or diode tests.
6. ALWAYS turn off power and disconnect test leads before opening the covers to replace the fuse
or battery.
7. NEVER operate the meter unless the back cover and the battery and fuse covers are in place
and fastened securely.
8. If the equipment is used in a manner not specified by the manufacturer, the protection provided
by the equipment may be impaired.
WARNING
CAUTION
MAX
600V
MN42-en-GB_v1.3 04/15
3
Controls and Jacks
1. Non-Contact Voltage Sensor
2. LCD Display
3. Function switch
4. Positive jack
5. COM jack
6. 10A jack
Note: Tilt stand, fuse, and battery compartment
are on rear of unit.
Symbols
•))) Continuity
Diode
µ micro (amps)
m milli (volts, amps)
k kilo (ohms)
 Ohms
Alternating (AC) current
Direct (DC) current
BAT Battery test
+-
Low battery icon
2
3
4
5
6
1

Produktspecifikationer

Varumärke: Extech
Kategori: Multimeter
Modell: MN42

Behöver du hjälp?

Om du behöver hjälp med Extech MN42 ställ en fråga nedan och andra användare kommer att svara dig




Multimeter Extech Manualer

Extech

Extech DM220 Bruksanvisning

19 September 2024
Extech

Extech MA440 Bruksanvisning

16 September 2024
Extech

Extech EX355 Bruksanvisning

16 September 2024
Extech

Extech EX623 Bruksanvisning

16 September 2024
Extech

Extech MA443 Bruksanvisning

16 September 2024
Extech

Extech EX320 Bruksanvisning

24 Augusti 2024
Extech

Extech MN36 Bruksanvisning

19 Augusti 2024
Extech

Extech DM110 Bruksanvisning

15 Augusti 2024
Extech

Extech EX540 Bruksanvisning

15 Augusti 2024

Multimeter Manualer

Nyaste Multimeter Manualer