Extech TM55 Bruksanvisning

Läs nedan 📖 manual på svenska för Extech TM55 (5 sidor) i kategorin Mattermometer. Denna guide var användbar för 13 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/5
USER GUIDE
Digital Food Thermometer
Model TM55
Introducon
Thank you for selecting the Extech Instruments Model TM55. The TM55 is NFS cered
for measuring the temperature of liquids, pastes, and semi-solids for all-purpose food
checks. The TM55 was designed for use in the food industry, in homes, businesses,
laboratories, agricultural applicaons (for soil), and educaonal facilies. This device is
shipped fully tested and calibrated and, with proper use, will provide years of reliable
service. Please visit our website (www.extech.com) to check for the latest User Guide,
Product Updates, and Support.
Features
Pocket size, fold-out thermometer
NSF cered for measuring liquids, pastes, and semi-solid foods
Probe length ); tapered probe p for easy inserons 2.4” (60 mm
Splash-proof housing is IP 65 rang
Ultrasonically welded housing with an-microbial addive
Automac Power OFF aer 60 minutes
Built-in magnec strip allows for appliance aachment
Dishwasher friendly (top rack only!)
2 TM55- _v1.2 3/20 EN
Safety
Before use please read the enre User Guide carefully
This product is intended for applicaons described in this User Guide only
Unauthorized repairs/modicaons/changes to this product are prohibited and
void the warranty
This instrument is not intended for use in medical applicaons or on medical
devices of any kind
Cauon! Risk of Injury
Keep this instrument and its baeries out of the reach of children
Be careful when using the probe. Always store the instrument safely folded.
Do not place baeries in a re
Do not short-circuit baeries
Do not dis-assemble the baeries
Do not aempt to re- arge the baeries. Risk of explosion! ch
Baeries can be fatal if swallowed, i swallowed get medical assistance immediately f
Baeries contain harmful acids. Low baeries should be replaced as soon as
possible to prevent damage caused by leaking baeries
Wear chemical-resistant gloves and eye protecon when handling leaking baeries
Important informaon on Product safety!
Do not expose the unit to extreme temperature, vibraon, or shock
Only the probe can withstand temperature up to 482 oF (250oC) not the instrument
Never place the probe directly over re
Geng Started
Using a coin, open the baery compartment by turning the compartment lid to the
le and then remove the insulang strip. Close the compartment aer removing
the insulang strip.
Remove the protecve display foil.
Carefully fold out the thermometer probe and the unit is now ready to use.
The sensor is located at the p of the probe. To measure temperature, insert the
probe into the material under test to a depth of at leas ). t 0.4” (1 cm
The probe has a rotaonal angle of 180 degrees maximum.
Switch the instrument power OFF by carefully folding the probe into its storage
posion.
The instrument will automacally switch OFF aer 60 minutes of inacvity. To
switch the instrument ON, fold the probe in for 4 seconds and then fold out again.
3 TM55- _v1.2 3/20 EN
Baery Replacement
When the low baery icon appear the display the and the icon ERROR on ,
CR2023 baery must be replaced:
Using a coin, open the baery compartment by turning the compartment lid to
the le
Remove the old battery and insert new CR2032 with the posive (+) side facing
upward
Close the baery compartment ghtly by turning the compartment lid to the right
Battery Safety Reminders
Please dispose of baeries responsibly; observe local, state, and naonal
regulaons.
Never dispose of baeries in a re; baeries may explode or leak.
Troubleshoong
NO DISPLAY:
Fold the probe in and wait several seconds. Then fold the probe out.
Check for baery and check for proper baery polarity (posive side facing up)
INCORRECT DISPLAY:
Replace baery
Check the posion of the probe; the probe must be inserted into test material to a depth
of at least ) 0.4” (1cm
Care and Maintenance
Clean the instrument with a damp cloth. Do not use abrasives, solvents, or scouring
agents
Remove the baery when the instrument is to be stored for long periods
Keep the instrument in a dry storage location
To prolong the baery life close (fold in) the probe when not in use

Produktspecifikationer

Varumärke: Extech
Kategori: Mattermometer
Modell: TM55

Behöver du hjälp?

Om du behöver hjälp med Extech TM55 ställ en fråga nedan och andra användare kommer att svara dig