Ferguson FS2SD Bruksanvisning
Ferguson
Rökdetektor
FS2SD
Läs nedan 📖 manual på svenska för Ferguson FS2SD (2 sidor) i kategorin Rökdetektor. Denna guide var användbar för 5 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2
3
4
2
5 6
7 8 9
Smoke Detector
User Manul
*Please read the user manual carefully before operation.
FS2SD
EN
Product introduction
This product is a photoelectric smoke Detector. It is
a warning device, cannot sense gas, heat, or flame,
cannot prevent or put out fire. It is capable of
real-time detecting the presence of smoke,
detection of visible particles (smoldering fire) faster
than ionization smoke alarms. Red LED flashes
rapidly and detectors sound alarm once detecting
smoke fire danger, can alert you and your family
timely. Smoke alarms should be installed in all
rooms, living room, storage areas, basements and
attics unit where fire may happen.
Specyfication
Sensor Bracket
Tips
1.This device is designed specifically for home use, may not to
able to provide sufficient fire alert for public areas.
2.Please avoid installation in bathrooms and other very humid
places, dusty or greasy areas, or very airy place with air
conditioning, ceiling fans, etc.
3.Please keep device clean, and do not let dust to accumulate. It
is recommended to clean every 6 months with a household
cleaner and a soft brush.
4.The effective lifespan is 10 years. Replacement every 10 years,
regardless of breakdown or not.
5.Please pay attention if it alarms. Besides proper use of alarm,
we should also strengthen the consciousness of fire safety.
Test/Hush Button
and LED indicator
●Ceiling mounting
●Sloping ceiling mounting
Recommended and Avoided
Instalation Position
Sloping Ceiling Mounting
Position
Instalation Renderings
l
Area that air does not flow
Ceiling Centre
The preferred location to install smoke alarm is in the centre of the ceiling
because Smoke, heat and combustion products rise to the ceiling and
will lateral spread. Keep at least 30 cm distance from lights or
decorations, and at least 15 cm away from walls and corner. If hall is
more than 12 meters wide, please install at 2 sides of the hall.
If ceiling is sloping, please install the smoke alarm at horizontal distance
90cm away from the ceiling top.
Anticlockwise rotating the bracket out from the installation
base, then remove the battery insulating strip to make
device on power.
Remove the double-sided adhesive membrane on the
mounting bracket, and rotating the smoke alarm into
the bracket.
1
2
3
4
1. Operating voltage: DC3V(CR123A Lithium Battery)
2. Static current: ≤ 10µ A
3. Alarm current: ≤ 60mA
4. Sound level: 85dB/3m
5. Working Temperature: -10 ~+50
°C
6. Working humidity: ≤ 95%RH
7. Dimension: 60*60*49.2mm
Select the Smart Hub from the list of devices to which you want to
add a new device (sensor) or device with factory settings restored.
1.Click add devices on APP, entering networking mode.
Adding device
When the LED in the control
panel blinks blue, we confirm
and go to pairing devices.
2. According to the tips on APP, keep pressing networking
button, green LED flashes quickly, tips appear on APP,
green LED keep on for 3 seconds, network success.
Delete device
In the application, click and hold the selected device, the "delete
device" command will be displayed. After removed it, disconnect
the network connection device by pressing and holding the pairing
button. 6-fold LED blink in green means disconnection of the
sensor network from the HUB.
10 11 12
Status
Please refer to the following situation, if the Alarm can not work normally:
1. Battery reaches service life (status refer to Form 1). Please replace
battery.
2. Fault affected by dirt with dust or oil, etc. (status refer to Form 1). Please
clean the alarm correctly.
3. Whether the alarm is properly rotated into the mounting bracke
Mute mode and Test
Mute function
Please make sure that there is no real danger of fire when using
mute function. Under known and non-fire alarm condition,
please do not block or by any other form to prohibit alarming.
Press the Test/Mute button to lower sensitivity and relieve alarm.
Press and hold the test panel Test/Mute button for 3 seconds, as
above picture shows, until alarm status (see status table).
Testing is recommended to be done at least once a week. Do not
use flame for testing. Once the alarm is sure to please pay
attention.
Battery Replacement
CR123A
*Please replace battery correctly, following the battery positive
and negative electrode. Attention to environmental protection and
dispose used battery properly.
13 14 15
16 17 18
Notice
1. The malfunction auto check function of this smoke alarm
only provides infrared photoelectric sensor malfunction check
and low battery power check. The sensor sensitivity should be
tested periodically as required.
2. To ensure the sensitivity to smoke, clean the smoke alarm
surface with soft brush or cleaner every 6 months. Do not use
solvent, liquid or detergent to clean the smoke alarm.
3. For malfunction problems, please contact with vendor on
time. Do not dismantle and try to repair alarms by yourself.
4. If smoke alarms are not used for a long time, dismount
them, remove batteries, put them in packing box and store in
cool place.
5. Photoelectric smoke alarms could reduce disaster
happening. But they can not guarantee a hundred percent
safety. For your safety concern, please use this smoke alarm
correctly and know the fire safety tips. In daily life, pay
attention to build up safety consciousness and take
preventive measures.
Fire safety tips
Follow fire safety rules and prevent hazardous situations:
1. Store combustible liquids such as gasoline in proper containers.
2. Never smoke in bed. After smoking a cigarette, put it out and place in a
correct container.
3. Check if power sockets, plugs or switches are broke. If cables are frayed
or cracked replace them.
4. Using power electric appliances such as heaters or heating equipments, do
not make the circuit overload and check periodically if these appliances work
properly.
5. Keep portable heaters and open flames, like candles, away from flammable
materials.
6. Keep matches or lighters away from children.
7. Keep at least one working fire extinguisher on every floor and an additional
one in the kitchen. Have fire escape ladders or other reliable means of escape
from an upper floor in case stairs are blocked.
8. Make sure all the family members know what to do after hearing an alarm
signal.
9. Install smoke alarms correctly according to manual. Keep alarms clean and
do not let dust accumulate and test them monthly. Replace them immediately
if they are not working properly.
* this device requires Ferguson Smart Hub unit to work, not included.
Normal
Testing
Alarm
Mute mode
Low power
Fault
Red LED flashes every 53 seconds
Red LED flashes quicly
Red LED flashes quicly
Red LED flashes every 10 seconds
Red LED flashes every 40 seconds
Red LED flashes every 40 seconds
NO
Rapid beeps
Rapid beeps
NO
Beep every 40 seconds
Beep every 40 seconds
Sta tus Light Ala rm Sound
Safety
1. Ferguson Sp. z o.o. is not responsible for damages caused by
improper use of the Ferguson Smart Home system.
2. Batteries attached to the device are not an integral part and not
a subject to complaint. The manufacturer is not responsible for
their proper operation.
3. Declared wireless ZigBee network’s range is based on
laboratory tests and applies to open space, keep in mind that the
materials used in the construction of houses and flats, wall
thickness and conditions of electromagnetic fields can cause a
significant reduction in network coverage.
Your product contains batteries covered by the
European Directive 2006/66/EC, which cannot
be disposed with normal household waste.
Please inform yourself about the local rules on
separate collection of batteries because correct
disposal helps to prevent negative
consequences for the environmental and human
health.
More info at
ferguson-digital.eu
and
wiki.ferguson.pl/en
Thanks!
Download app: Ferguson Smart
Produktspecifikationer
Varumärke: | Ferguson |
Kategori: | Rökdetektor |
Modell: | FS2SD |
Behöver du hjälp?
Om du behöver hjälp med Ferguson FS2SD ställ en fråga nedan och andra användare kommer att svara dig
Rökdetektor Ferguson Manualer
24 September 2024
24 September 2024
Rökdetektor Manualer
- Rökdetektor Bosch
- Rökdetektor IKEA
- Rökdetektor Siemens
- Rökdetektor Abus
- Rökdetektor Alecto
- Rökdetektor AngelEye
- Rökdetektor Brennenstuhl
- Rökdetektor Nedis
- Rökdetektor Pyle
- Rökdetektor Vivanco
- Rökdetektor Blaupunkt
- Rökdetektor Elro
- Rökdetektor EMOS
- Rökdetektor KlikaanKlikuit
- Rökdetektor Ei Electronics
- Rökdetektor Hama
- Rökdetektor Smartwares
- Rökdetektor Marquant
- Rökdetektor ESYLUX
- Rökdetektor Olympia
- Rökdetektor Kidde
- Rökdetektor Hager
- Rökdetektor FireAngel
- Rökdetektor Chacon
- Rökdetektor First Alert
- Rökdetektor TFA
- Rökdetektor Clas Ohlson
- Rökdetektor Konig
- Rökdetektor BRK
- Rökdetektor Busch-Jaeger
- Rökdetektor Gira
- Rökdetektor Jung
- Rökdetektor FireX
- Rökdetektor DSC
- Rökdetektor Fito
- Rökdetektor FirstAlert
- Rökdetektor Nexa
- Rökdetektor Satel
- Rökdetektor Calex
- Rökdetektor Mobeye
- Rökdetektor FireHawk
- Rökdetektor X-Sense
- Rökdetektor ORNO
- Rökdetektor Mercury
- Rökdetektor Heatit
- Rökdetektor Kogan
- Rökdetektor Gloria
- Rökdetektor H-Tronic
- Rökdetektor System Sensor
- Rökdetektor Pyrexx
- Rökdetektor Jemay
- Rökdetektor Mircom
- Rökdetektor WisuAlarm
- Rökdetektor Cordes
- Rökdetektor STI
- Rökdetektor Deltronic
- Rökdetektor Insafe
- Rökdetektor Gewiss
- Rökdetektor No-Flame
- Rökdetektor Egardia
- Rökdetektor GEV
- Rökdetektor Frient
- Rökdetektor Qolsys
- Rökdetektor SAVS
Nyaste Rökdetektor Manualer
18 Oktober 2024
16 Oktober 2024
16 Oktober 2024
16 Oktober 2024
14 Oktober 2024
9 Oktober 2024
8 Oktober 2024
8 Oktober 2024
3 Oktober 2024
3 Oktober 2024