Fluke 1663 Bruksanvisning
Fluke
Multimeter
1663
Läs nedan 📖 manual på svenska för Fluke 1663 (94 sidor) i kategorin Multimeter. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/94

October 2015, Rev. 2, 10/22
© 2015-2022 Fluke Corporation. All rights reserved.
Specifications are subject to change without notice.
All product names are trademarks of their respective companies.
1662/1663/1664 FC
Electrical Installation Tester
Users Manual

LIMITED WARRANTY AND LIMITATION OF LIABILITY
Each Fluke product is warranted to be free from defects in material and workmanship
under normal use and service. The warranty period is three years and begins on the date
of shipment. Parts, product repairs, and services are warranted for 90 days. This warranty
extends only to the original buyer or end-user customer of a Fluke authorized reseller,
and does not apply to fuses, disposable batteries, or to any product which, in Fluke's
opinion, has been misused, altered, neglected, contaminated, or damaged by accident or
abnormal conditions of operation or handling. Fluke warrants that software will operate
substantially in accordance with its functional specifications for 90 days and that it has
been properly recorded on non-defective media. Fluke does not warrant that software will
be error free or operate without interruption.
Fluke authorized resellers shall extend this warranty on new and unused products to end-
user customers only but have no authority to extend a greater or different warranty on
behalf of Fluke. Warranty support is available only if product is purchased through a Fluke
authorized sales outlet or Buyer has paid the applicable international price. Fluke re-
serves the right to invoice Buyer for importation costs of repair/replacement parts when
product purchased in one country is submitted for repair in another country.
Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price,
free of charge repair, or replacement of a def returned to a Fluke ective product which is
authorized service center within the warranty period.
To obtain warranty service, contact your nearest Fluke authorized service center to obtain
return authorization information, then send the product to that service center, with a de-
scription of the difficulty, postage and insurance prepaid (FOB Destination). Fluke as-
sumes no risk for damage in transit. Following warranty repair, the product will be re-
turned to Buyer, transportation prepaid (FOB Destination). If Fluke determines that failure
was caused by neglect, misuse, contamination, alteration, accident, or abnormal condition
of operation or handling, including overvoltage failures caused by use outside the prod-
uct’s specified rating, or normal wear and tear of mechanical components, Fluke will pro-
vide an estimate of repair costs and obtain authorization before commencing the work.
Following repair, the product will be returned to the Buyer transportation prepaid and the
Buyer will be billed for the repair and return transportation charges (FOB Shipping Point).
THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF
ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED
TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTIC-
ULAR PURPOSE. FLUKE SHALL NOT BE LIABLE FOR ANY SPECIAL, INDIRECT,
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, INCLUDING LOSS OF
DATA, ARISING FROM ANY CAUSE OR THEORY.
Since some countries or states do not allow limitation of the term of an implied warranty,
or exclusion or limitation of incidental or consequential damages, the limitations and ex-
clusions of this warranty may not apply to every buyer. If any provision of this Warranty is
held invalid or unenforceable by a court or other decision-maker of competent jurisdiction,
such holding will not affect the validity or enforceability of any other provision.
Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.
Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands
11/99

i
Table of Contents
Title Page
Introduction ................................................................................ 1
How to Contact Fluke ................................................................. 1
Safety ......................................................................................... 2
Features and Accessories .......................................................... 2
Operation ................................................................................... 5
Safety Features ...................................................................... 5
Touch Pad ........................................................................... 5
Live Circuit Detection .......................................................... 5
Earth Resistance Measurement .......................................... 5
Safety Pretest ...................................................................... 6
Mains Wiring Indicator ......................................................... 6
Quick Start .............................................................................. 6
How to Use the Rotary Dial ................................................. 6
Push Buttons ....................................................................... 8
Display ................................................................................ 10
Input Terminals ................................................................... 14
Error Codes ......................................................................... 15
Power-On Options ............................................................... 17
How to Zero the Test Leads ................................................ 19
Safety Pretest for Insulation Resistance Measurements ..... 23
Measurements............................................................................ 25
Volts and Frequency Measurements ...................................... 25
Insulation Resistance Measurements ..................................... 26
Continuity Measurement ......................................................... 29
Loop/Line Impedance Measurements ..................................... 31
Loop Impedance (Line to Protective Earth L-PE) ................ 31
Loop Impedance (High-Current Trip Mode)......................... 34
Loop Impedance in IT System Measurement ...................... 36
Line Impedance ................................................................... 36
RCD Tripping Time Measurements ........................................ 39
Custom RCD Setting – Var mode ....................................... 43
RCD Tripping Time in Auto mode ....................................... 45
RCD Tripping Current Measurements .................................... 47
RCD Tests in IT Systems ....................................................... 51
Produktspecifikationer
Varumärke: | Fluke |
Kategori: | Multimeter |
Modell: | 1663 |
Behöver du hjälp?
Om du behöver hjälp med Fluke 1663 ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Fluke Manualer

2 Oktober 2024

26 September 2024

12 September 2024

11 September 2024

11 September 2024

10 September 2024

10 September 2024

10 September 2024

9 September 2024

9 September 2024
Multimeter Manualer
- Multimeter Abus
- Multimeter Alecto
- Multimeter Appa
- Multimeter Amprobe
- Multimeter Amiko
- Multimeter Silverline
- Multimeter Brennenstuhl
- Multimeter Ferm
- Multimeter Workzone
- Multimeter Yato
- Multimeter Milwaukee
- Multimeter Elro
- Multimeter EMOS
- Multimeter Extech
- Multimeter Tacklife
- Multimeter Schneider
- Multimeter Metrix
- Multimeter Benning
- Multimeter Voltcraft
- Multimeter Somogyi
- Multimeter Velleman
- Multimeter Profile
- Multimeter Steren
- Multimeter Kyoritsu
- Multimeter Ideal
- Multimeter Flir
- Multimeter Maxwell
- Multimeter Digitus
- Multimeter Testboy
- Multimeter Hager
- Multimeter TFA
- Multimeter Clas Ohlson
- Multimeter Powerfix
- Multimeter Owon
- Multimeter Basetech
- Multimeter Projecta
- Multimeter Etekcity
- Multimeter Greenlee
- Multimeter Högert
- Multimeter Laserliner
- Multimeter REV
- Multimeter Testo
- Multimeter Keithley
- Multimeter Monacor
- Multimeter Metrel
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Brandson
- Multimeter GW Instek
- Multimeter Skandia
- Multimeter Elma
- Multimeter Testec
- Multimeter Beha-Amprobe
- Multimeter Hubinont
- Multimeter Vimar
- Multimeter Uni-T
- Multimeter Kewtech
- Multimeter Strex
- Multimeter Mastech
- Multimeter PeakTech
- Multimeter Sonel
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Gossen Metrawatt
- Multimeter Rigol
- Multimeter PCE Instruments
- Multimeter Micronta
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Joy-it
- Multimeter Klein Tools
- Multimeter Aim TTi
- Multimeter Kurth Electronic
- Multimeter Wiha
- Multimeter IWH
- Multimeter Weltron
- Multimeter Sanwa
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nyaste Multimeter Manualer

14 Mars 2025

14 Mars 2025

8 Januari 2025

3 Januari 2025

1 Januari 2025

29 December 2024

29 December 2024

29 December 2024

29 December 2024

28 December 2024