Fluke 73 Bruksanvisning
Fluke
Multimeter
73
Läs nedan 📖 manual på svenska för Fluke 73 (12 sidor) i kategorin Multimeter. Denna guide var användbar för 4 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/12

®
73
Series III Multimeter
Instruction Sheet
Read First: Safety Information
W To avoid damage to the meter, electric shock or injury:
• Never use the meter if the meter or test leads look damaged.
• Be sure the test leads and rotary switch are in the correct
position for the desired measurement.
• Never measure resistance in a circuit when power is applied.
• Never touch the probes to a voltage source when the test
leads are plugged into the 10 A or 300 mA input jack.
• Never use the meter on circuits that exceed 4800 volt-amps.
• Never apply more than the rated voltage between any input
jack and earth ground.
• Be careful when working with voltages above 60 V dc or 30 V
ac rms. Such voltages pose a shock hazard.
• Keep your fingers behind the finger guards on the test probes
when making measurements.
W Warning
To avoid false readings, which could lead to possible
electric shock or personal injury, replace the battery
as soon as the low battery indicator (M) appears.
Symbols
WCaution: Important Information. See instruction sheet.
MAN Manual Range.
TDouble Insulation.
MLow battery. Replace battery.
CAT II Overvoltage Installation Category per IEC 61010-1-95.
CAT II instruments protect against transients from
equipment supplied from the fixed installation, e.g., TV,
PC, and household appliances.
PN 1646063 February 2002 (English)
1 97, 1 98 00 F uke o p rat on. r ht r se e . r nt d n9 9 , 2 2 l C r o i All ig s e rv d P i e i China.

Terminals
300
mA
10A
FUSED
600V CAT
V
COM
Milliamps
Amps
Volts, Ohms, Diode Test
Common Terminal
hr2f.eps
See Specifications for overload protection.
Pushbutton
Use the pushbutton to either select a fixed range or put the meter
in the Automatic Touch Hold mode.
Autorange
The meter defaults to autorange when first turned on.
Manual Range
Manual ranging is available in V ac, V dc, ohms, A ac, and A dc.
The manual range mode and Touch Hold mode are mutually
exclusive. is displayed when the meter is in the manualMAN
range mode.
Momentary
+_
V
MAN
hr14f.eps
To return to autorange, press for 1 second or change theR
measurement function.

Automatic Touch Hold Mode
W Warning
To avoid electric shock, do not use the Touch Hold
mode to determine if a circuit with high voltage is
dead. The Touch Hold mode will not capture
unstable or noisy readings.
The Touch Hold mode automatically captures and displays stable
readings. Press for 2 seconds. RHOLD is displayed when
the meter is in the Touch Hold mode.
2 seconds
+_
V DC V DC
_+_
single
beep
V V V
HOLD HOLD
V DC
HOLD
hr3f.eps
When the meter captures a new input, it beeps and a new
reading is displayed.
Note
Stray voltages can produce a new reading.
To exit the Touch Hold mode, press R or change the
measurement function. The Touch Hold mode and manual range
mode are mutually exclusive.
Bar Graph
The bar graph shows readings relative to the full scale value of a
displayed measurement range and indicates polarity.
hr16f.eps
Produktspecifikationer
Varumärke: | Fluke |
Kategori: | Multimeter |
Modell: | 73 |
Behöver du hjälp?
Om du behöver hjälp med Fluke 73 ställ en fråga nedan och andra användare kommer att svara dig
Multimeter Fluke Manualer

2 Oktober 2024

26 September 2024

12 September 2024

11 September 2024

11 September 2024

10 September 2024

10 September 2024

10 September 2024

9 September 2024

9 September 2024
Multimeter Manualer
- Multimeter Abus
- Multimeter Alecto
- Multimeter Appa
- Multimeter Amprobe
- Multimeter Amiko
- Multimeter Silverline
- Multimeter Brennenstuhl
- Multimeter Ferm
- Multimeter Workzone
- Multimeter Yato
- Multimeter Milwaukee
- Multimeter Elro
- Multimeter EMOS
- Multimeter Extech
- Multimeter Tacklife
- Multimeter Schneider
- Multimeter Metrix
- Multimeter Benning
- Multimeter Voltcraft
- Multimeter Somogyi
- Multimeter Velleman
- Multimeter Profile
- Multimeter Steren
- Multimeter Kyoritsu
- Multimeter Ideal
- Multimeter Flir
- Multimeter Proline
- Multimeter Maxwell
- Multimeter Digitus
- Multimeter Testboy
- Multimeter Hager
- Multimeter TFA
- Multimeter Clas Ohlson
- Multimeter Powerfix
- Multimeter Owon
- Multimeter Basetech
- Multimeter Projecta
- Multimeter Etekcity
- Multimeter Greenlee
- Multimeter Högert
- Multimeter Laserliner
- Multimeter REV
- Multimeter Testo
- Multimeter Keithley
- Multimeter Monacor
- Multimeter Metrel
- Multimeter Multimetrix
- Multimeter Digi-tool
- Multimeter Brandson
- Multimeter GW Instek
- Multimeter Skandia
- Multimeter Elma
- Multimeter Testec
- Multimeter Beha-Amprobe
- Multimeter Hubinont
- Multimeter Vimar
- Multimeter Uni-T
- Multimeter Kewtech
- Multimeter Strex
- Multimeter Mastech
- Multimeter PeakTech
- Multimeter Sonel
- Multimeter MBS
- Multimeter MGL Avionics
- Multimeter Chauvin Arnoux
- Multimeter Megger
- Multimeter Gossen Metrawatt
- Multimeter Rigol
- Multimeter PCE Instruments
- Multimeter Micronta
- Multimeter CEM
- Multimeter Horex
- Multimeter Cosinus
- Multimeter Joy-it
- Multimeter Klein Tools
- Multimeter Aim TTi
- Multimeter Kurth Electronic
- Multimeter Wiha
- Multimeter IWH
- Multimeter Weltron
- Multimeter Sanwa
- Multimeter Rohde & Schwarz
- Multimeter EEVBlog
- Multimeter Kingcraft
- Multimeter Weidmüller
- Multimeter HT Instruments
- Multimeter Caltek
- Multimeter Elworks
- Multimeter Qian
- Multimeter Bearware
- Multimeter Noyafa
Nyaste Multimeter Manualer

26 Mars 2025

14 Mars 2025

14 Mars 2025

8 Januari 2025

3 Januari 2025

1 Januari 2025

29 December 2024

29 December 2024

29 December 2024

29 December 2024