GEV 16897 Bruksanvisning
GEV
Rörelsedetektor
16897
Läs nedan 📖 manual på svenska för GEV 16897 (6 sidor) i kategorin Rörelsedetektor. Denna guide var användbar för 8 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/6
Max. 14 Ct./Min aus dem deutschen Festnetz.
Mobil max. 42 Ct./Min.
International calls may vary.
GEV GmbH
Heidehofweg 16
25499 Tangstedt
Germany
www.gev.de
service@gev.de
Hotline: +49 (0)180/59 58 555
www.gev.de
Typ: Einbau-Bewegungsmelder
ATHLET MINI 360° LBD 16897
BA01175800
16WOA31
16897
A B
2 3
C
ROT
BRAUN
BLAU
LOAD
~IN
N L
on on on on on on on on
NIGHT/
24 HOURS
SENS
TIME
1 2
16 mm
76
Subject to technical and design changes without prior notice.
DEGBFRITPL
How it works
The motion detector operates using passive infrared technology.
Via a PIR sensor, the detector notices any heat sources moving
within its field of detection and switches on automatically.
Static heat sources do not trigger it. The adjustable twilight
switch lets you choose whether you have the motion detector
working day and night or only when it is dark. The integrated
timer also lets you adjust how long the light stays on.
Safety information
To be fitted by qualified electricians only, observing all
standard national installation regulations.
No work to be carried out while live. The circuit trip
switch must therefore be switched o.
Check to make sure the connecting cable is not live!
All warranty claims will be null and void in the event of any
damage or loss caused by failure to observe these operating
instructions. We accept no liability for any consequential
losses or damage. We accept no liability for any personal injury
or material damage caused by improper use or by failure to
observe the safety advice.
In such cases all warranty claims will be null and void. For
reasons of safety and approval, no unauthorised conversion
and/or modification of the appliance is allowed.
Where to install
The motion detector is at its most eective when approached
diagonally. Motion detectors should therefore always be set up
so that they are not directly approached.
Installation
The Inset Mini Motion Detector LBD consists of two parts:
Fig. A1 Fig. A2an inset sensor a power section. Disconnect
the inset sensor plug from the power section. Make a 16 mm-
diameter hole in the area in which you wish to install the device
and push the inset sensor into it. After installing the inset
sensor, reconnect the plug to the power section. Mount the
power pack in place . (Fig. A)
Connect the mains connection cable as shown in the circuit
diagram . Switch the circuit trip switch back on. (Fig. B)
Range test
Set the dip switch to 5 sec. and the TIME night/24 hours dip
switch to „24 hours (dip switch position OFF)“. If the motion
detector is switched on via a separate switch, turn this on. A
self-test is then initiated lasting approx. 30 seconds. When the
device turns o, the range test will begin. The device will now
switch on for approx. 5 seconds in response to any movement,
regardless of the ambient lighting level. This time period is
initiated by any movement from the front. This range test is
designed to help you to determine the field of detection. Set
the Sens dip switch according to your requirements (dip switch
position o, high sensitivity). Once this has been adjusted
successfully you will be able to make further settings.
Settings (Fig. C)
TIME: Time setting for switch-on time 5 sec. – 8 min. The
switch-o delay time is selected by moving the dip switch to
the „ON“ position.
NIGHT/24HOURS: Twilight switch 10 , dip switch position Lux
ON: If the brightness of the ambient light is less than 10 , the Lux
connected consumer is switched on. Twilight switch 2000 Lux,
dip switch position OFF: If the brightness of the ambient light
is less than 2000 Lux, the connected consumer is switched on.
Recycling instructions
This device may not be disposed of with the unsorted
household waste. Owners of old devices are required by
law to dispose of this device professionally. Contact your
town council for further information.
Recessed-mounted motion detector
ATHLET MINI 360° LBD 16897
Technical data
Field of detection 360° with a beam angle of 120°
Range approx. 6 m
Time adjustment the time adjustment can be set via the dip switch: 5 sec., 30 sec., 1 min., 3 min., 5 min., 8 min.
Twilight switch can be configured via dip switch, approx. 10 Lux/approx. 2000 Lux
Mains connection 230 V ~, 50 Hz
Switching capacity max. 200 W LEDs, max. 200 W energy saving lamp, max. 800 W incandescent lamps
Power consumption approx. 0,5 W
Protection type IP 44 for the sensor, IP 20 for the power section
Protection class II
Troubleshooting – Practical tips
Problem Cause Remedy
Motion detector switches the
light on too late
• Movement from the front “ dip switch to O (dip switch • Set „Sens
down)
Motion detector fails to achieve
maximum range
• Motion detector is mounted too low
• Dierence in temperature between heat source
and surroundings is not big enough
• Mount higher
Motion detector switches
light
on constantly or
when not necessary
• Constant thermal movement:
There are areas within detection range that are not
supposed to be monitored, e.g. footpaths, roads,
trees etc. Unexpected changes in heat sources
caused by storms, rain or fans.
The influence of direct / indirect sunlight
Produktspecifikationer
Varumärke: | GEV |
Kategori: | Rörelsedetektor |
Modell: | 16897 |
Behöver du hjälp?
Om du behöver hjälp med GEV 16897 ställ en fråga nedan och andra användare kommer att svara dig
Rörelsedetektor GEV Manualer
20 September 2024
20 September 2024
20 September 2024
Rörelsedetektor Manualer
- Rörelsedetektor Philips
- Rörelsedetektor Honeywell
- Rörelsedetektor Abus
- Rörelsedetektor Alecto
- Rörelsedetektor ACME
- Rörelsedetektor Hikvision
- Rörelsedetektor Nedis
- Rörelsedetektor Yale
- Rörelsedetektor Lucide
- Rörelsedetektor Eminent
- Rörelsedetektor Blaupunkt
- Rörelsedetektor Optex
- Rörelsedetektor Schneider
- Rörelsedetektor Axis
- Rörelsedetektor Theben
- Rörelsedetektor Velleman
- Rörelsedetektor Techly
- Rörelsedetektor Vemer
- Rörelsedetektor Smartwares
- Rörelsedetektor Steren
- Rörelsedetektor Perel
- Rörelsedetektor Steinel
- Rörelsedetektor IFM
- Rörelsedetektor ESYLUX
- Rörelsedetektor Olympia
- Rörelsedetektor Devolo
- Rörelsedetektor Dahua Technology
- Rörelsedetektor Cotech
- Rörelsedetektor Arlo
- Rörelsedetektor Grothe
- Rörelsedetektor Merten
- Rörelsedetektor Goobay
- Rörelsedetektor Hager
- Rörelsedetektor Massive
- Rörelsedetektor Konig
- Rörelsedetektor Busch-Jaeger
- Rörelsedetektor D-Link
- Rörelsedetektor Swann
- Rörelsedetektor DESQ
- Rörelsedetektor Xavax
- Rörelsedetektor Marmitek
- Rörelsedetektor Orbis
- Rörelsedetektor Jung
- Rörelsedetektor DSC
- Rörelsedetektor HQ
- Rörelsedetektor Fibaro
- Rörelsedetektor Iget
- Rörelsedetektor Nexa
- Rörelsedetektor Satel
- Rörelsedetektor Wentronic
- Rörelsedetektor EQ3
- Rörelsedetektor Homematic IP
- Rörelsedetektor Vernier
- Rörelsedetektor Crestron
- Rörelsedetektor Chuango
- Rörelsedetektor ORNO
- Rörelsedetektor Berker
- Rörelsedetektor Extron
- Rörelsedetektor Maxsa
- Rörelsedetektor Kopp
- Rörelsedetektor Vimar
- Rörelsedetektor Kogan
- Rörelsedetektor XQ-Lite
- Rörelsedetektor Brinno
- Rörelsedetektor Legrand
- Rörelsedetektor Elgato
- Rörelsedetektor Intertechno
- Rörelsedetektor Schwaiger
- Rörelsedetektor Inovonics
- Rörelsedetektor V-Tac
- Rörelsedetektor Bitron
- Rörelsedetektor EQ-3
- Rörelsedetektor InLine
- Rörelsedetektor Suevia
- Rörelsedetektor EtiamPro
- Rörelsedetektor Pentatech
- Rörelsedetektor Joy-it
- Rörelsedetektor RAB
- Rörelsedetektor BEA
- Rörelsedetektor Tellur
- Rörelsedetektor Megatron
- Rörelsedetektor Ledvance
- Rörelsedetektor Gewiss
- Rörelsedetektor ALC
- Rörelsedetektor Avigilon
- Rörelsedetektor Pepperl+Fuchs
Nyaste Rörelsedetektor Manualer
9 Januari 2025
31 December 2025
30 December 2025
30 December 2025
30 December 2025
27 December 2024
27 December 2024
26 December 2024
17 December 2024
17 December 2024