System 2000 Tronic switching Insert
Installation Instructions
System 2000 Tronic switching Insert 2/06 Page 1 of 3
Function
Function
Function
FunctionFunction
The Tronic switching insert is a device provided with
an electronic switch and serving for switching light
installations or electrical consumers:
230 V incandescent lamps.
230 V halogen lamps.
LV halogen lamps in conjunction with Tronic
transformers.230V Glühlampen
Events are caused by switching commands from the
covers such as automatic switch or presence detec-
tor attachment.
Switching commands given through an extension or
a radio transmitter lead to well-directed turning on or
off.
The lamps are turned on by a gentle soft start.
This Operating Instructions leaflet describes the
functionality in combination with the presence
detector attachment. For the exact functionalities in
conjunction with the use of other attachments or of
the remote control unit, please refer to the corre-
sponding Operating Instructions leaflets.
Installati
Installati
Installati
InstallatiInstallation
on
on
on on Instructions
Instructions
Instructions
InstructionsInstructions
Install Tronic switching insert in a connection box
as per DIN 49073 (Fig. A).
The terminals of the Tronic switching insert must be
down.
Use the Tronic switching insert only in combination
with an attachment.
Plug attachment onto Tronic switching insert
together with frame .
The electrical contact is established through plug
contacts .
Mains failures of longer than 1 sec. will lead to
turning off the Tronic switching insert.
Short
Short
Short
ShortShort-Circuit Protection
-Circuit Protection
-Circuit Protection
-Circuit Protection-Circuit Protection
Switching off with automatic restarting after short-
circuit elimination within 7 sec. For longer short-cir-
cuits, permanent switching off until a manual restart
is triggered when an attachment is used.
Overtemperatur
Overtemperatur
Overtemperatur
OvertemperaturOvertemperature Protection
e Protection
e Protection
e Protectione Protection
Switching off in case of excessively high ambient
temperature. After cooling down, the device must be
restarted
Fig A
System 2000
Tronic switching Insert
Order no.: 0866 00
GIRA
GIRA
GIRA
GIRAGIRA
Info
Info
Info
InfoInfo
System 2000 Tronic switching Insert
Installation Instructions
System 2000 Tronic switching Insert 2/06 Page 2 of 3
Connection
Connection
Connection
ConnectionConnection
Connect as shown in Fig. B.
Tronic switching insert .
Load .
Fig B
Depending upon the type of installation, the maxi-
mum connected load must be reduced by:
- 6,5 % per 5 °C exceeding of the ambient
temperature of 25°C.
- 15% for installation in wooden, gypsum plaster or
hollow walls.
- 20% for installation in multiple combinations.
Note the technical connection conditions of the
power stations.
T
T
T
TThe Use of Extensions
he Use of Extensions
he Use of Extensions
he Use of Extensionshe Use of Extensions
Connect several extensions as shown in Fig. C.
Fig C
Control from an extension unit is possible only if the
attachment on the main unit is in place.
Tronic switching insert .
Extension insert .
Connection of further extensions .
Load .
Extension insert: Using the attachment
leads to the same functio-
nality as on the Tronic
switching insert.
Mechanical push-button
(n. o. contact): ON/OFF (toggling)
Illuminated mechanical pushbuttons must have a
separate N terminal.
i:
Observe the maximum connected load and the load
details as set out in the Technical Specifications.
Safety instructions:
Attention: Electrical equipment must be installed
and fitted by qualified electricians only. Not suitable
for safety disconnection.
Shutting off does not disconnect the load electrical-
ly from the mains.
Non-observance of the installation instructions may
cause fire or other hazards.
iImportant:
Not suitable for disconnecting.
Not suitable for operation in conjunction with con-
ventional transformers.
Do not change the attachment while mains voltage
is applied, as this will entail malfunctioning.
GIRA
GIRA
GIRA
GIRAGIRA
Info
Info
Info
InfoInfo
System 2000 Tronic switching Insert
Installation Instructions
System 2000 Tronic switching Insert 2/06 Page 3 of 3
T
T
T
TTechnical specifications
echnical specifications
echnical specifications
echnical specificationsechnical specifications
Nominal voltage: AC 230 V ~, 50 / 60 Hz
Operating temperature: -20 °C ... +45 °C
Connected load: 50 - 420 W/VA
- Incandescent lamps
- HV halogen lamps
- Tronic transformers
Number of Extensions:
extension insert,
mechanical push-button: unlimited
extension insert for
presence detedtor
and automatic switch: 10
Different types of extension units can be combined
Total length of extension
connecting cable: max. 100 m
Acceptance of guarantee
We accept the guarantee in accordance with the corresponding legal provisions.
Please return the unit postage paid to our central service department giving a brief description of the
fault:
Gira
Giersiepen GmbH & Co. KG
Service Center
Dahlienstrasse 12
D-42477 Radevormwald
The CE sign is a free trade sign addressed exclusively to the authorities and does not include
any warranty of any properties.
Gira
Giersiepen GmbH & Co. KG
Elektro - Installations - Systeme
Dahlienstraße 12
42477 Radevormwald
Tel + 49 (0) 2195 - 602 - 0
Fax + 49 (0) 2195 - 602 - 339
www.gira.de

Produktspecifikationer

Varumärke: Gira
Kategori: Smarth hem
Modell: 086600

Behöver du hjälp?

Om du behöver hjälp med Gira 086600 ställ en fråga nedan och andra användare kommer att svara dig




Smarth hem Gira Manualer

Smarth hem Manualer

Nyaste Smarth hem Manualer