Grothe 1068/021 Bruksanvisning

Grothe Detektor 1068/021

Läs nedan 📖 manual på svenska för Grothe 1068/021 (12 sidor) i kategorin Detektor. Denna guide var användbar för 10 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/12
DS106 00 206428- 8A LBT
LCD COMMAND KEYPAD
CLAVIER DE COMMANDE LCD
STEUERTASTATUR LCD
Ref. 8/ 1106 02
Through the following QR Code, it is possible to download the eventual new version of the booklet in
English, French and German l .anguage
http://qrcode.urmet.com/default.aspx?prodUrmet=141753&lingua=en
INSTRUCTION MANUAL
LIVRET D'INSTRUCTIONS
BEDIENUNGSANLEITUNG
Mod.
1068
2 8- 8A DS106 00
ENGLISH
GENERAL DESCRIPTION
The 1068/021 indoor display keypad, used to control and program the 1068 serie system is equipped with : s
LCD backlit display with contrast and luminosity regulation;
3 LED to signal the system status (Power supply, Recommendations Zone status , );
18 -protected alphanumerical keys; door
buzzer with adjustable volume;
1 programmable i . nput
A tamper jumper is supplied with the product to bypass the keypad opening/removal button. Use of this
feature will cancel EN50131 certication.
The keypad is powered by the bus that connects it to the control panel.
WARNING! In this document there are only present some essential indications about product.
For further and more detailed information, refer to manuals concerning 1068 series control panels.
POSITIONING
Keypad must be positioned:
in an environment that is sheltered and protected from water and humidity;
on a dry and level wall;
in the vicinity of the accesses to area to be protected;
in an inner location which is not subjected to excessive sudden
rises/falls in temperature, and is protected by anti-burglar system at ;
160 cm height for normal installations. For disabled or special needs
users of the D1 type (elderly) and D2 type (lower limb motor
diculties), must be arranged at a height comprised between 75 cm and 140 the centre of the device
cm with respect to the oor. For more details, see technical standard CEI 64-21:2016- Residential 12
environments. Systems suited for use by people with disabilities or special needs.
KEYPAD OPENING
Use a slotted screwdriver to open the keypad by gently pressing the point indicated in the image in order to
disengage the closure spur and lift the cover (Fig. 1).
INSTALLAT ION
For running the cables, open the provided hole on the bottom of the keypad ( Fig. 2). Otherwise, the D -
scored holes for the cable ducts can be used ( Fig. 2). E -
Secure the keypad bottom to the wall by means of 6 mm plugs ( Fig. 2 - not provided). During xing A/B -
always use also the hole ( Fig. 2) for the protection against removal. C -
If bottom is fastened over round or rectangular a 3-place built-in box (e.g. BTICINO 503), use holes (A or B)
and suitable screws.
WARNING! before xing, verify the bottom direction: cover closing hook shall be positioned at the
bottom.
For easier wiring, it is advisable to strip the cable as far as the access hole.
Fig. 1
DS1068- 8A 3 00
Close the keypad by screwing the screw provided in the hole. ( Fig. 1). F -
BUS CONNECTION
Keypad can be connected on bus either in a cascade or star Keypad position along bus is not important. .
The overall length of all bus sections must not exceed 400 metres.
For wiring, use 4 lead screened cable for anti-intrusion (2 leads for power supply and 2 leads for data
connection). Lead section must be chosen taking into account voltage drop caused by connection length In .
counting out overall system absorption, also consider max consumption in keypad mA). (95
KEYPAD CAPTURE
To acquire the keypad the first time it is switched on, press the key
associated with the symbol that appears on the display F1 .
Proceed as follows to restore default settings (Reset) on the keypad, if
necessary:
Disconnect power from the keypad
Open the keypad tamper protection
Restore power supply to the keypad
Press the key associated with the symbol within 10 seconds (Fig.3). F1
Another screen will appear (Fig.4).
Press the key associated with the symbol to conrm parameter reset. F1
Press the key associated with CancelF3 symbol to return to the
previous screen
For further information about capture procedure, refer to manual concerning
control unit installation.
Fig. 2
Fig. 3
Fig. 4

Produktspecifikationer

Varumärke: Grothe
Kategori: Detektor
Modell: 1068/021

Behöver du hjälp?

Om du behöver hjälp med Grothe 1068/021 ställ en fråga nedan och andra användare kommer att svara dig




Detektor Grothe Manualer

Grothe

Grothe 1068/021 Bruksanvisning

16 September 2024

Detektor Manualer

Nyaste Detektor Manualer