Hestan GESB08 Bruksanvisning

Hestan Utegrill GESB08

Läs nedan 📖 manual på svenska för Hestan GESB08 (28 sidor) i kategorin Utegrill. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/28
©2017 Hestan Commercial Corporation
1
EN
OUTDOOR LIVING
SUITE
(WITH CUSTOMER-PROVIDED STONE TOP)
INSTALLATION INSTRUCTIONS
GES08, GESB08, GES12, GESB12
IMPORTANT - READ ALL INSTRUCTIONS BEFORE YOU BEGIN
THE INSTALLATION HEREIN SHOULD BE PERFORMED BY A QUALIFIED SERVICE TECHNICIAN
OR PROFESSIONAL OUTDOOR EQUIPMENT INSTALLER. MANY COMPONENTS ARE HEAVY AND
REQUIRE 2 OR 3 PERSONS TO UN-PACK AND SETUP THIS SUITE. FAILURE TO DO SO MAY RESULT
IN PERSONAL INJURY.
THE ELECTRICAL COMPONENTS SUPPLIED WITH THIS SUITE MUST BE INSTALLED BY A
LICENSED ELECTRICIAN AND CONNECTED IN ACCORDANCE WITH LOCAL CODES. THE SUITE
SHOULD BE CONNECTED TO A DEDICATED CIRCUIT BREAKER. ALL OUTLETS SUPPLIED WITH
THIS SUITE ARE GROUND FAULT CIRCUIT INTERRUPTER OUTLETS AND MUST BE PROPERLY
INSTALLED AND GROUNDED BY A LICENSED ELECTRICIAN TO GUARANTEE SAFE AND RELIABLE
OPERATION.
SOME PARTS INSIDE THE SUITE HAVE SHARP EDGES. CARE MUST BE TAKEN WHEN HANDLING
THE VARIOUS COMPONENTS TO AVOID PERSONAL INJURY. WEAR GLOVES WHEN HANDLING.
TOOLS REQUIRED:
Work gloves
Safety glasses
Power drill with masonry bits
Concrete / masonry anchors & hardware
Flat and Phillips screwdrivers
Socket wrench with 7/16” & 9/16” sockets and short extensions
Combination wrenches of 7/16” & 9/16” sizes
Level
IF THE INFORMATION IN THE GAS-FIRED APPLIANCE MANUALS
ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT
CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Flammable Gas - disconnect all propane or natural gas supplies to this unit
before servicing.
Electrical Parts & Components – disconnect all power supplies and
batteries before servicing.
AFTER INSTALLATION OF YOUR GRILL AND OTHER GAS-FIRED EQUIPMENT IN THIS
SUITE, READ THE MANUAL(S) PROVIDED WITH THOSE PRODUCTS CAREFULLY AND
COMPLETELY BEFORE USING YOUR GRILL TO REDUCE THE RISK OF FIRE, BURN
HAZARD, OR OTHER INJURY. KEEP THIS MANUAL FOR FUTURE REFERENCE.
©2017 Hestan Commercial Corporation
2
EN
SUITE MODELS WITH CUSTOMER-PROVIDED TOP
Suite GES08 shown with:
GABR36 Built-In Gas Grill
ABG122 Double Side Burner
AGAD36 Double Access Doors
GRSR24 Outdoor Fridge
ALL ITEMS PURCHASED SEPARATELY
STONE TOP NOT INCLUDED
Below are representations of Hestan Outdoor Living Suites covered in this manual.
Suite GESB12 shown with:
GABR42 Built-In Gas Grill
ABG122 Double Side Burner
AGTC Trash Chute
AGAD42 Double Access Doors
AGDR16 Double Drawers
AGTRC20 Trash & Recycling Center
GFDSR241 Outdoor Single Faucet Beer Dispenser
ALL ITEMS PURCHASED SEPARATELY
STONE TOPS NOT INCLUDED
©2017 Hestan Commercial Corporation
3
EN
LOCATING THE SUITE
When determining a suitable location for your suite, take into account concerns such as exposure
to wind, rain, sprinklers, proximity to traffic paths, and keeping any gas supply line runs as short
as possible.
Locate the grill only in a well-ventilated area. Never locate the grill in a building, breezeway, shed
or other such enclosed areas without an approved ventilation system. Never locate the grill over,
under, or next to unprotected combustible construction.
During heavy use, the grill will produce a lot of heat and smoke. The grill is designed to take in
cool air at the front control panel area, and send the combustion products and smoke out the
exhaust gap at the rear of the hood. It is important to maintain this flow at all times. Using the
grill in windy areas can disrupt this proper flow and cause damage to your grill, or result in burn
hazards to the user. See Fig. 1 for details.
The Hestan Outdoor Living suite features ventilation openings (louvers) on each end. These
openings must be clear to avoid accumulation of gas should there be a leak. These openings are
further described later in this manual.
Figure 1
CURB INSTALLATION
1. The Hestan Outdoor Living Suite must be located on a level concrete or masonry patio
surface, not on direct soil. A licensed plumber and electrician should run their service
lines to the suite area prior to installation of the curb, in accordance with local codes. See
dimensions below for recommended location. See ELECTRICAL ITEMS section of this
manual for details. The gas line to the suite will require a shut-off that is easily accessible.
Local codes may also require a tracer wire be buried alongside the gas line for underground
detection. See the GAS CONNECTIONS section of this manual, and the appliance manual(s)
for more details.