Hikvision DS-PDMC-EG2-WB Bruksanvisning
Hikvision
Larmsystem
DS-PDMC-EG2-WB
Läs nedan 📖 manual på svenska för Hikvision DS-PDMC-EG2-WB (3 sidor) i kategorin Larmsystem. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/3
DS-PDMC-EG2-WE/WB
Wireless Magnet Detector
Diagram References
E N G L I S H
©2023 Hangzhou Hikvision Digital Technology Co., Ltd. All rights reserved.
About this Manual
The Manual includes instructions for using and managing the Product. Pictures, charts, images and all other information hereinafter are for description and explanation only. The information contained in the Manual is subject to change,
without notice, due to firmware updates or other reasons. Please find the latest version of this Manual at the Hikvision website (https://www.hikvision.com/).
Please use this Manual with the guidance and assistance of professionals trained in supporting the Product.
Trademarks
and other Hikvision’s trademarks and logos are the properties of Hikvision in various jurisdictions.
Other trademarks and logos mentioned are the properties of their respective owners.
Disclaimer
TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW, THIS MANUAL AND THE PRODUCT DESCRIBED, WITH ITS HARDWARE, SOFTWARE AND FIRMWARE, ARE PROVIDED “AS IS” AND “WITH ALL FAULTS AND ERRORS”. HIKVISION MAKES
NO WARRANTIES, EXPRESS OR IMPLIED, INCLUDING WITHOUT LIMITATION, MERCHANTABILITY, SATISFACTORY QUALITY, OR FITNESS FOR A PARTICULAR PURPOSE. THE USE OF THE PRODUCT BY YOU IS AT YOUR OWN RISK. IN NO EVENT WILL
HIKVISION BE LIABLE TO YOU FOR ANY SPECIAL, CONSEQUENTIAL, INCIDENTAL, OR INDIRECT DAMAGES, INCLUDING, AMONG OTHERS, DAMAGES FOR LOSS OF BUSINESS PROFITS, BUSINESS INTERRUPTION, OR LOSS OF DATA, CORRUPTION OF
SYSTEMS, OR LOSS OF DOCUMENTATION, WHETHER BASED ON BREACH OF CONTRACT, TORT (INCLUDING NEGLIGENCE), PRODUCT LIABILITY, OR OTHERWISE, IN CONNECTION WITH THE USE OF THE PRODUCT, EVEN IF HIKVISION HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR LOSS.
YOU ACKNOWLEDGE THAT THE NATURE OF THE INTERNET PROVIDES FOR INHERENT SECURITY RISKS, AND HIKVISION SHALL NOT TAKE ANY RESPONSIBILITIES FOR ABNORMAL OPERATION, PRIVACY LEAKAGE OR OTHER DAMAGES RESULTING
FROM CYBER-ATTACK, HACKER ATTACK, VIRUS INFECTION, OR OTHER INTERNET SECURITY RISKS; HOWEVER, HIKVISION WILL PROVIDE TIMELY TECHNICAL SUPPORT IF REQUIRED.
YOU AGREE TO USE THIS PRODUCT IN COMPLIANCE WITH ALL APPLICABLE LAWS, AND YOU ARE SOLELY RESPONSIBLE FOR ENSURING THAT YOUR USE CONFORMS TO THE APPLICABLE LAW. ESPECIALLY, YOU ARE RESPONSIBLE, FOR USING THIS
PRODUCT IN A MANNER THAT DOES NOT INFRINGE ON THE RIGHTS OF THIRD PARTIES, INCLUDING WITHOUT LIMITATION, RIGHTS OF PUBLICITY, INTELLECTUAL PROPERTY RIGHTS, OR DATA PROTECTION AND OTHER PRIVACY RIGHTS. YOU
SHALL NOT USE THIS PRODUCT FOR ANY PROHIBITED END-USES, INCLUDING THE DEVELOPMENT OR PRODUCTION OF WEAPONS OF MASS DESTRUCTION, THE DEVELOPMENT OR PRODUCTION OF CHEMICAL OR BIOLOGICAL WEAPONS, ANY
ACTIVITIES IN THE CONTEXT RELATED TO ANY NUCLEAR EXPLOSIVE OR UNSAFE NUCLEAR FUEL-CYCLE, OR IN SUPPORT OF HUMAN RIGHTS ABUSES.
IN THE EVENT OF ANY CONFLICTS BETWEEN THIS MANUAL AND THE APPLICABLE LAW, THE LATTER PREVAILS.
1Introduction
The sensor can detect the door or window opening. When the door or window is open, an alarm will be triggered and it will be sent to the alarm center or mobile client
via security control panel.
Door Magnetic Sensor Alarm: When the distance between the sensor and the magnetic stick is longer than 3 cm, an alarm will be triggered. The indicator will ash once.
Tamper Alarm: When removing the sensor, an alarm will be triggered.
2
Appearance
1
2
3
4
6
Indicator
Alarm Detection: Red LED ashes.
Detector Formatted: Red LED ashes 3 times.
Display Signal Strength:
Under the signal strength checking mode:
Solid Green for 3 s - Strong Signal
Solid Orange for 3 s - Medium Signal
Solid Red for 3 s - Weak Signal
Red light ashes for 3S, interval 250 ms - Failure
1
2TAMPER Button
Tampering Alarm: If the detector is disassembled, an alarm will be triggered.
Formatting: Remove the battery. Hold the TAMPER button and power the detector on at the same time. The red LED ashes 3 time when the formatting is
completed.
3Power Switch
4Interface
Battery
Installation Datum Line
5
5
6
Figure 2-1 Appearance
UD18214B
CAUTION
RISK OF EXPLOSION IF BATTERY
IS REPLACED BY AN INCORRECT
TYPE.
REPLACEMENT OF A BATTERY
WITH AN INCORRECT TYPE THAT
CAN DEFEAT A SAFEGUARD.
CAUTION
CHEMICAL BURNING DANGER
DO NOT SWALLOW THE
BATTERY
KEEP NEW AND USED
BATTERIES AWAY FROM THE
CHILDREN.
IF YOU THINK BATTERIES MIGHT
HAVE BEEN SWALLOWED OR
PLACED INSIDE ANY PART OF
THE BODY, SEEK IMMEDIATE
MEDICAL ATTENTION.
CAUTION
DISPOSE OF USED BATTERIES
ACCORDING TO THE INSTRUC-
TIONS AND LOCAL REGULATION.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Dig the groove to disassemble the device. Remove the front and rear panel. Turn the power switch to ON to power on the device.
Note: Do not disassemble the device with sharps.
3Power On
4Enrollment
Figure 3-1 Power On
1. Check Signal Strength
Enter the signal checking mode by operating on the control panel. Trigger the detector.
Solid Green for 3 s - Strong Signal
Solid Orange for 3 s - Medium Signal
Solid Red for 3 s - Weak Signal
Red light ashes for 3S, interval 250 ms - Failure
2. Install the Detector
Dig the groove to disassemble the device.
Method 1: Secure the rear panel to the wall with two screws.
Method 2: Paste rear panel on the wall with the sponge tape.
Note: To make the TAMPER work properly, the thickness of the sponge tape should be no more than 1mm.
Close the front and the rear panel.
Note: You should install the sensor and the magnetic stick at the door or window’s edge. Make sure they are aligned with the door or window’s edge.
5Installation
6Functions
OR
Figure 5-1 Installation
1Enroll the Peripheral Locally
2Enroll the Peripheral with QR and serial No.
1. Log in to the APP Store, download and install Hik-Connect.
2. Power on the security control panel.
3. Log in the APP and tap the icon "+" . Scan the QR code or input the control panel serial No. to add the control panel.
1. In the APP, tap the "Enrollment Mode" button on the control panel page to make the control
panel enter the enrollemnt status.
2. Power on the peripheral, and it will be automatically enrolled to the control panel.
1. In the APP, tap the icon "+"and scan the QR code or serial No. on the peripheral.
2. Power on the peripheral, and it will be automatically enrolled to the control panel.
Function Description
The alarm will be triggered while the gap between the sensor and magnetic stick is
bigger than that shows in the table. The LED keeps blue for 2 s.
You can add two external inputs (each input can be set as NO\NC\TAMPER\Pulse) via
the AX PRO client.
While Any of the two inputs generates an alarm event, the contact reports the alarm to
the AX PRO. The LED keeps blue for 2 s.
Test
The cotact starts test automatically after being enrolled to the AX PRO. The LED turn
red.
Separate the contact, and make a gap between the sensor and stick. while the LED
turns green, the alarm is triggered by this gap . Adjust the installation position of the
contact to get a satised alarm gap.
Alarm
CAUTION
IF THE BATTERY COMPARTMENT
DOES NOT CLOSE SECURETLY,
STOP USING THE PRODUCT AND
KEEP IT AWAY FROM CHILDREN.
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
8Specication
7
Operation Caution and Device Maintenance
- All the electronic operation should be strictly compliance with the electrical safety regulations, re prevention
regulations and other related regulations in your local region.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation.
Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment
damage).
- Please make sure that the power has been disconnected before you wire, install or dismantle the device.
- If smoke, odors or noise rise from the device, turn o the power at once and unplug the power cable, and then
please contact the service center.
- Do not drop the device or subject it to physical shock, and do not expose it to high electromagnetism radiation.
Avoid the equipment installation on vibrations surface or places subject to shock (ignorance can cause equipment
damage).
- Do not place the device in extremely hot (refer to the specication of the device for the detailed operation
temperature), cold, dusty or damp locations, and do not expose it to high electromagnetic radiation.
- The device for indoor use shall be kept from rain and moisture.
Exposing the equipment to direct sun light, low ventilation or heat source such as heater or radiator is forbidden
(ignorance can cause re danger).
- Do not aim the device at the sun or extra bright places. A blooming or smear may occur otherwise (which is not
a malfunction however), and aecting the endurance of sensor at the same time.
- Improper use or replacement of the battery may result in hazard of explosion. Replace with the same or
equivalent type only. Dispose of used batteries according to the instructions provided by the battery manufactur-
er.
- Do not expose the device to the corrosive gas. Otherwise the equipment damage may occur.
- Do not expose the device to the explosive situation.
One reed switch Yes
External Inputs 2
Tamper protection Front & Back
LED indicator Blue (alarm)
Encapsulated plastic Yes
Input options Normal and Fast Sensitivity with Pulse Count
Programmable pulse count Yes
Fast input sensitivity 1ms
Normal input sensitivity 250ms
Operating temperature -10 °C ot 55 °C (14 °F to 131 °F)
Storage temperature -20 °C ot 60 °C (-4 °F to 140 °F)
Operating humidity 10% to 90%
Weight 59 g
Programming method Advanced Wireless Link
LED indicator On/O
External Input 1 NC/NO, Roller Shutter (RS), Tamper
External Input 2 NC/NO, Roller Shutter (RS), Tamper
RS Pulse Count 2 to 30 Pulses
RS Pulse Count Timeout 10 to 60s
Environment temperature indicator Yes
2-way wireless communication Yes
Transmission frequency 868/433MHz
Frequency hopping Multichannel transmisstion
Transmission encryption AES-128 encryption
Signal strength indicators Yes
RF range WE:1.6 Km/WB:1.2 km(open space)
Enrolling methods Power up, Remote ID, QR code
Battery CR123A x 1 (included)
Standard battery life 5 years
Dimension (H × W × D) 103 mm × 22.5 mm × 23.2 mm
Hangzhou Hikvision Digital Technology CO.,Ltd. No.555 Qianmo Road, Binjiang District, Hangzhou 310052, China
Produktspecifikationer
Varumärke: | Hikvision |
Kategori: | Larmsystem |
Modell: | DS-PDMC-EG2-WB |
Behöver du hjälp?
Om du behöver hjälp med Hikvision DS-PDMC-EG2-WB ställ en fråga nedan och andra användare kommer att svara dig
Larmsystem Hikvision Manualer
22 September 2024
22 September 2024
20 September 2024
11 September 2024
4 September 2024
4 September 2024
3 September 2024
2 September 2024
2 September 2024
2 September 2024
Larmsystem Manualer
- Larmsystem IKEA
- Larmsystem Gigaset
- Larmsystem Honeywell
- Larmsystem Abus
- Larmsystem Nedis
- Larmsystem Yale
- Larmsystem Pyle
- Larmsystem Eminent
- Larmsystem Renkforce
- Larmsystem Blaupunkt
- Larmsystem Ezviz
- Larmsystem Elro
- Larmsystem Doro
- Larmsystem Dometic
- Larmsystem Smartwares
- Larmsystem Burg-Wachter
- Larmsystem Somfy
- Larmsystem Olympia
- Larmsystem Dahua Technology
- Larmsystem FireAngel
- Larmsystem Chacon
- Larmsystem Konig
- Larmsystem Swann
- Larmsystem DESQ
- Larmsystem X4-Tech
- Larmsystem M-e
- Larmsystem Basetech
- Larmsystem Electia
- Larmsystem Ring
- Larmsystem Gripo
- Larmsystem FBT
- Larmsystem Chuango
- Larmsystem ORNO
- Larmsystem ETiger
- Larmsystem Redmond
- Larmsystem Vimar
- Larmsystem Schwaiger
- Larmsystem Woonveilig
- Larmsystem EVOLVEO
- Larmsystem Olymp
- Larmsystem Schabus
- Larmsystem Qolsys
- Larmsystem Bearware
Nyaste Larmsystem Manualer
3 Oktober 2024
3 Oktober 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024
30 September 2024