Hikvision DS-PS110-WB Bruksanvisning

Hikvision Larmsystem DS-PS110-WB

Läs nedan 📖 manual på svenska för Hikvision DS-PS110-WB (1 sidor) i kategorin Larmsystem. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/1
For DS-PS110-WE:
EN 50131-1:2006+A1:2009+A2:2017+A3:2020
EN 50131-4:2019
EN 50131-5-3:2017
Security Grade 2
Environment Class II
Wireless Sounder Indoor
User Manual
Hangzhou Hikvision Digital Technology CO.,Ltd.
No.555 Qianmo Road, Binjiang District,
Hangzhou 310052, China
UD35507B
User Manual Flow Chart
1 Appearance
1.1 Unbox.
1.2 Check components
and indicator.
Enroll the device to control panel.
3.1 Check signal strength and
volume.
3.2 Install the device.
Configure device parameters
on the APP.
1 Appearance
2 Enrollment
3 Installation
4 Configuration
93mm
33.7
mm
93mm
Indicator Tamper
Serial Port
Battery
Buzzer
Indicator Status Device Status
Blue/Red LED flashes Alarm
Blue/Red LED flashes once Armed
Blue/Red LED flashes twice Disarmed
Green LED flashes Delay on arming/
disarming
Green LED flashes continuously Find me
Orange LED flashes Enrolling
Green LED flashes 7 times Enrolled
Blue/Red LED flashes rapidly Offline
Parameter Operation
Name Edit device name.
Area Select linked area or add new area.
Sound
Indication
Select the volume level of alarm,
armed/disarmed, delay on arming/
disarming sound.
LED Indication
After enabled, when the alarm
triggers, the device is armed or
disarmed, or the device is delayed
on arming or disarming, the LED
indicator will display different status.
Alarm Duration The alarm indication ends after the
selected duration time.
Deactivation The selected part will be
deactivated.
Find Me Enter the find me mode to search for
the device location.
2 Enrollment 4 Configuration
Specification3 Installation
Step 1. Download Hik-Connect/Hik-Partner Pro and log
in. Enroll the control panel to the APP.
Note: For more details, refer to the user manual of Hik-
Connect, Hik-Partner Pro APP and .control panel
Step 2. Add DeviceOn the device list page, tap .
2.1 Select , scan the QR code or enterManual Adding
the serial No.
2.2 Select , the device will be enrolled toBatch Adding
control panel automatically.
Step 3. Slide down to remove the rear cover. Install 4
batteries into the device. Orange LED starts to flash.
Step 4. The green LED flashes for 7 times, the device is
enrolled.
Step 1. Tap the sounder on the device list page.
Step 2. Tap → Signal Strength Test, check signal
strength.
Step 3. Tap → Volume Test, listen to different levels
of volume, and select the appropriate level.
Step 4. Fix the rear cover to the wall with 4 screws.
And install the front cover.
Step 5. After the device is installed, you can view the
device status, alarm duration, version, etc.
Tap the sounder on the device list page, and tap to
configure device parameters.
Model DS-PS110-WE DS-PS110-WB
Installation Indoors
Indication method Acoustic and LED
Sound volume level Adjustable, 80−95 dB at a distance of 1 m
Alarm length Adjustable, 1 s−15 min
Indication of armed/
disarmed status Yes
Power supply 4 × AA batteries
Power consumption Max current: 400 mA
Quiescent current: 35 uA
Battery life Up to 2 years (standby time)
Temperature indicator Yes
Transmission
technology
Tri-X
868.0 to 868.6 MHz
Tri-X
433.1 to 433.7 MHz
Transmission range (free
space) Up to 1,600 m Up to 1,200 m
Maximum effective
radiated power (ERP) Up to 25 mW Up to 10 mW
Tamper Yes
Operating temperature -10 °C to 55 °C (14 °F to 131 °F)
Operating humidity 10% to 90%
Protection class of body No
Dimension
(W × H × D) 93 × 93 × 33.7 mm
Weight 117 g