INSTALLATION AND USER GUIDE
69-2457EFS-05
RPLS730B / RPLS731B
Programmable Wall Switch
APPLICATIONS
The RPLS730B / RPLS731B programmable wall switch has been designed to
control lightings and motors:
INSTALLATION
NOTE: This switch cannot be used if there are not at least 2 white wires joined
by a connector inside the electrical box.
1. Cut power at the circuit breaker to avoid electric shock.
2. Remove the existing switch.
3. Install the new switch as shown in the diagram below.
4. Apply power at the circuit breaker.
Load type Maximum load Examples
Resistive load 2400 W (20 A @ 120 V) •incandescent lights
•halogen lights
•block heater
Inductive load 2400 W (20 A @ 120 V) •fluorescent lights
•compact fluorescent lights (CFL)
•sodium lamps
•electronic ballasts
Motor 1 hp •pool filter pumps
•fans
M38497
120 VAC (line)
blue (load)
white (neutral)
Load
black (line)
RPLS730B / RPLS731B PROGRAMMABLE WALL SWITCH
69-2457EFS—05 2
POWER-ON
1. Pry the switch door open from the bottom
using a small screwdriver.
2. Ensure the ON/OFF selector is set to ON.
3. 0:00Reset the switch using a paper clip. will
flash.
If the display is blank:
• Ensure the ON/OFF selector is properly
engaged in the ON position. Push it to the right
using a small screwdriver.
• At first power-up after the installation, the
screen of the switch may be blank or dim, or
become so when you turn the light on. However,
during that time, the switch is fully functional. Wait 2 minutes for the
switch’s built-in battery to be sufficiently charged and the screen will
return to its normal contrast.
SETTING THE CLOCK
NOTE: The switch displays the time in 24-hour format by default or follow-
ing a reset.
1. To change to 12-hour format (or vice versa), proceed as follows:
• Press one of the control buttons to ensure the MAN or AUTO
indicator is displayed.
• Press the MIN and HOUR buttons simultaneously and briefly (0:00
display = 24-hour, 12:00 display = 12-hour).
2. Set the time using the HOUR and MIN buttons. If you have selected
the 12-hour format, ensure that PM appears on the screen when an
afternoon time is displayed.
3. Set the day using the DAY button.
4. Press one of the control buttons or close the switch door to return to
normal operation.
SELECTING THE OPERATING MODE
The programmable switch has 2 operating modes: manual (MAN) and
automatic (AUTO). To switch mode, press the switch door for 3 seconds.
Manual mode
The programmable switch operates as a regular switch.
Briefly press the switch door to turn the lights On or Off.
The mode ( ) and state (MAN ON or OFF) are displayed.
Automatic mode
The programmable switch follows the programmed
schedule. The mode (AUTO), state (ON or OFF) and
current program number are displayed. To temporarily
override the programmed schedule, briefly press the
switch door. The new state (ON or OFF) will flash to show
that this state is temporary. The override remains in effect
until you press the switch door again or until the beginning of the next
program.
M38498
Reset
Control (4)
On/Off selector
M38499
RPLS730B / RPLS731B PROGRAMMABLE WALL SWITCH
3 69-2457EFS—0 5
PROGRAMMING THE SCHEDULE
You can set up to 7 programs. To set a program, you need to enter its start
time (ON) and its end time (OFF).
1. Pry the switch door open using a small screwdriver.
2. Press the PGM button to display a program and its
On or Off time. For example, when you first press
PGM, program number 1 (P1) and its On time (ON)
will appear. - : - - will appear instead of the time if the
program is not set (inactive).
3. Press the DAY button to select the day to which you
want to apply the program.
4. NOTE: If you want to apply the program to every day
of the week, press DAY until all the days are
displayed. (This still counts as 1 program, not 7)
5. Press the buttons to set the HOUR and MIN ON time
(time when you want the lights to turn on). If you have selected the 12-
hour format, ensure that PM appears on the screen when an afternoon
time is displayed.
6. After you have programmed the ON time, press the PGM button to
display the OFF time (time when you want the lights
to turn off).
7. Repeat steps 3 through 5 to program the OFF time. If
the program ON time is set for every day of the week,
the program OFF time will automatically be set for
every day.
8. To set another program, repeat steps 2 through 6.
Programs that are not set will remain inactive.
9. Press one of the control buttons or close the switch door to return to
normal operation.
Clearing a programmed time
Press the PGM button as many times as needed to display the programmed
time. Hold the PGM button for 3 seconds. - : - - appears when the
programmed time is erased.
TROUBLESHOOTING
Blank display •Verify circuit breaker at main panel.
•Ensure the ON/OFF ON selector is at .
•Reset the switch using a paper clip.
Faded or irregular display Ambient temperature below freezing point
Cannot switch between 24-hour
format and 12-hour format
First, press one of the control buttons so that
MAN or AUTO appears on display.
Programs do not run as expected •Make sure the switch is properly programmed.
•Note that - : - - indicates an inactive program.
•If the switch has been configured for 12-hour
format, check that PM appears on the left side of
the screen when an afternoon time is displayed.
The switch resets itself without
apparent reason when used to control
an inductive load such as a relay or a
contactor.
The reset is caused by the load. Install a snubber
(AC130-03) at each relay/contactor.
M38500
M38501
Produktspecifikationer
Varumärke: | Honeywell |
Kategori: | Växla |
Modell: | RPLS730B1000 |
Behöver du hjälp?
Om du behöver hjälp med Honeywell RPLS730B1000 ställ en fråga nedan och andra användare kommer att svara dig
Växla Honeywell Manualer
21 September 2024
21 September 2024
31 Augusti 2024
24 Augusti 2024
24 Augusti 2024
1 Augusti 2024
Växla Manualer
- Växla Bosch
- Växla IKEA
- Växla Huawei
- Växla HP
- Växla Panasonic
- Växla Yamaha
- Växla Alcatel
- Växla Alecto
- Växla Ansmann
- Växla Edimax
- Växla Intermatic
- Växla Flamingo
- Växla Brennenstuhl
- Växla Hikvision
- Växla Generac
- Växla Silvercrest
- Växla Nedis
- Växla Pyle
- Växla Renkforce
- Växla Vivanco
- Växla TP Link
- Växla Manhattan
- Växla Worx
- Växla Black Box
- Växla Elro
- Växla EMOS
- Växla Victron Energy
- Växla KlikaanKlikuit
- Växla Tripp Lite
- Växla DataVideo
- Växla Schneider
- Växla Theben
- Växla Elektrobock
- Växla Chamberlain
- Växla Sylvania
- Växla Velleman
- Växla Tork
- Växla Techly
- Växla Sonance
- Växla Emerson
- Växla Totolink
- Växla Vemer
- Växla Profile
- Växla Matrox
- Växla Steren
- Växla Perel
- Växla Engenius
- Växla IFM
- Växla Digitus
- Växla Kathrein
- Växla AV:link
- Växla Belkin
- Växla Linksys
- Växla Dahua Technology
- Växla Audiovox
- Växla Cotech
- Växla Netgear
- Växla LevelOne
- Växla Kaiser
- Växla QNAP
- Växla Boss
- Växla Shimano
- Växla Merten
- Växla Hager
- Växla Chacon
- Växla Elation
- Växla Sygonix
- Växla Planet
- Växla ZyXEL
- Växla Rex
- Växla Powerfix
- Växla Konig
- Växla Tesla
- Växla D-Link
- Växla Tenda
- Växla UPM
- Växla One For All
- Växla Finder
- Växla Marmitek
- Växla Delta Dore
- Växla DoorBird
- Växla Ubiquiti Networks
- Växla EBERLE
- Växla Grasslin
- Växla Omnitronic
- Växla Jung
- Växla CyberPower
- Växla Basetech
- Växla Trendnet
- Växla Mikrotik
- Växla WHALE
- Växla ATen
- Växla Fibaro
- Växla RGBlink
- Växla Gefen
- Växla Nexa
- Växla PAC
- Växla Dormakaba
- Växla Adder
- Växla Wago
- Växla Homematic IP
- Växla Monoprice
- Växla Tiptel
- Växla OSD Audio
- Växla SPC
- Växla Crestron
- Växla Unify
- Växla ORNO
- Växla Berker
- Växla Electro Harmonix
- Växla Grandstream
- Växla Mercury
- Växla Provision ISR
- Växla Monacor
- Växla PCE
- Växla Logilink
- Växla Smart-AVI
- Växla StarTech.com
- Växla SIIG
- Växla Advantech
- Växla IOGEAR
- Växla Micro Connect
- Växla Extron
- Växla KanexPro
- Växla Blustream
- Växla Avocent
- Växla Shelly
- Växla Intellinet
- Växla Ebode
- Växla Lancom
- Växla Robbe
- Växla B-tech
- Växla Speaka
- Växla Kopp
- Växla Vimar
- Växla Kemo
- Växla GAO
- Växla H-Tronic
- Växla Legrand
- Växla Kraus & Naimer
- Växla Noble
- Växla Intertechno
- Växla Ecler
- Växla Inverto
- Växla Triax
- Växla Rule
- Växla Kramer
- Växla CYP
- Växla Suevia
- Växla Phoenix Contact
- Växla Seuthe
- Växla Maclean Energy
- Växla SmartAVI
- Växla DEHN
- Växla Cudy
- Växla Brilliant
- Växla Heitronic
- Växla Lindy
- Växla SEC24
- Växla Cooking Performance Group
- Växla Ernitec
- Växla Atlona
- Växla Adviti
- Växla Flic
- Växla IB Connect
- Växla Liberty
- Växla Hamlet
- Växla Paladin
- Växla Equip
- Växla Noark
- Växla Vivolink
- Växla Alfatron
- Växla Cambium Networks
- Växla 2USB
- Växla Roline
- Växla KVM-TEC
- Växla AMX
- Växla BZBGear
- Växla STI
- Växla Epiphan
- Växla Ebara
- Växla Mach Power
- Växla Axing
- Växla Juniper
- Växla Raritan
- Växla ConnectPro
- Växla SunBriteTV
- Växla Atlantis Land
- Växla GEV
- Växla Pizzato Elettrica
- Växla Baco
- Växla SEADA
- Växla Doepke
- Växla Comet
- Växla IPGARD
- Växla CSL
- Växla Setti+
- Växla PureLink
- Växla INOGENI
- Växla Luxul
Nyaste Växla Manualer
15 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025
14 Januari 2025