Installation in concrete ceiling
CAUTION:
For concrete mounting, the drilled hole must be recommend-
ed by the manufacturer of the anchor (this is usually marked
on the anchor) and must be drilled at least 1/2" deeper than
the length of the anchor.
The holes must be made with a suitable carbide-tipped
masonry drill bit.
The anchors must be new and unused.
The concrete ceiling must be sound and free of cracks or
voids in the vicinity of the mounting holes.
The anchors must be set in flush with the surface of the
concrete.
The bracket screws must never be backed out. If the bracket
screws can be turned easily (by hand), do not hang fan.
Installation
Drill holes 2" deep in concrete ceiling to receive 1/4" x 11
/2"
expansion shield anchor, “Rawl No. 1055” or equal. (Not fur-
nished.) Install shield in holes, observing all cautions above.
Proceed with the installation of the fan per the basic installa-
tion instructions.
The Inside Story
Oil is constantly pumped up the spiral groove to lubricate the
rotor and shaft. The oil is returned to the reservoir where the
bearings are submerged in a bath of oil.
This unique lubrication system is built into all Original Hunter
Ceiling Fans. That’s one reason Hunters last so long. And why
we can offer a Limited Lifetime Warranty.
Fill in the blanks below for your record.
Serial number
Model number
Date purchased Date installed
Dealer/store name where purchased
4
41121-01 9/95
Trouble shooting guide
Problem Probable Cause Solution
1. Nothing 1. Power turned 1. Turn power on or
happens; off or fuse replace fuse.
blades do blown.
not rotate.* 2. Loose wire 2. Loosen canopy.
connections Check all
or wrong connections (turn
connections. power off while
checking).
3. Pull chain 3. Pull switch cord.
switch not
“on”.
4. Reversing 4. Slide reversing
switch in switch either up or
center. down.
* Note: If blades will not turn by hand, contact your nearest
service representative or dealer.
1. Noisy 1. Blade irons 1. Tighten screws until
operation. loosely snug.
screwed to
rotor.
2. Blade 2. Tighten.
screwed
loosely to
blade iron.
3. Blade cracked. 3. Replace all 4 blades.
Contact dealer.
4. Canopy 4. Lower canopy.
contacting
ceiling.
5. No oil or low 5. Check oil level.
oil level.
1. Excessive 1. Unbalanced 1. Rebalance (See
wobbling blades. Step 7D).
2. Inadequate 2. Relocate fan.
blade
clearance.
3. Loose blades 3. Tighten all screws.
or blade irons.
4. Fan not 4. Turn power off.
secure on Support fan very
hanger carefully. Loosen
assembly. canopy and hang
correctly.
1.
2.
3.
4.
5.
6.
A.
B.
HUNTER FAN COMPANY
25 00 FRISCO AVENUE
M E MP H I S , T N 3 8 1 1 4
®
Fig. 18
Hanger
Bracket Bracket
Power
Leads
Used With
Light Kit
Canopy
Set Screw
Oil Filler Hole
Oil Return
Rotor
Field
Windings Oil Reservoir
Bearing Nut
Switch Housing Cover
Bushing Pin
Ground Screw
Pipe Nipple (Std.)
Shaft
Cast Iron
Fan Housing
Cast Metal
Lower
Cover
Spiral
Groove
Bearings
Switch Housing
Pull Chain
Switch
expansion
shield anchor
set flush with
ceiling (anchor
not furnished)
Concrete ceiling
Bracket
(Furnished with fan)
Fig. 17
The installation of your Hunter Ceiling Fan
NOTE TO INSTALLERS: Please leave this manual with the
owner.
Tools needed:
• Pliers 11/64" bit
• Flat blade screwdriver • 3 wire connectors
• Phillips screwdriver • 4" x 11/2" standard octagon
• Electric drill electrical outlet box
• 3/8" Socket wrench
Step 1: Pre-installation
Select installation site: Normally this is near the center of
the room, often replacing a light fixture. Make certain that
ample clearance is left for the rotating fan blades. For maxi-
mum efficiency, no obstruction (walls, posts, etc.) should be
within 24" of the tips of the blades (see Fig. 1). Mounting
site should also meet the precautions listed in Step 3.
Fan mounting height: Your Hunter fan comes with the proper
hardware to hang the fan from a standard 8 foot ceiling so
the fan blades will be 12" from the ceiling and approximately
7 feet from the floor (see Fig. 1).
NOTE: On vaulted ceilings, up to 45° pitch, you may want to
use the Hunter Vaulted Ceiling Mounting Kit.
Step 2: Inspect fan
Unpack the fan carefully to avoid any damage to com-
ponents.
CAUTION: NEVER LIFT THE MOTOR BY THE WIRES.
L E T M OT O R R E S T IN T H E C A R T ON L I N E R F OR
PROTECTION.
Check the sack parts.
Step 3: Installation of ceiling mounting hardware
CAUTION: YOUR HUNTER CEILING FAN WEIGHS UP TO 50
LBS. THE FOLLOWING PRECAUTIONS MUST BE TAKEN FOR
SAFETY AND TO ENSURE THAT YOUR FAN IS SECURELY
MOUNTED TO THE CEILING.
• When inspecting or preparing installation site where wiring
is available, make sure electricity is off at fuse box or
circuit breaker panel.
• All wiring must meet local and national codes.
• Do not mount directly to an unsupported ceiling or to an
electrical outlet box.
The wood joist chosen for mounting the fan must be
sound and of sufficient size. In no case, should it be
smaller than standard 2" x 4" lumber.
Secure a metallic outlet box 4" x 11/2" or 4" x 1/2" deep to
2 x 4 cross brace between two ceiling joists as shown in
Figure 3. The outlet box must be recessed in the ceiling by
1/16" minimum. Secure the outlet box to the cross brace by
drilling (2) pilot holes no larger than the minor diameter of
the woodscrews ( 5/64") and use two #8 x 11
/2" woodscrews
and washers. Use the innermost holes for securing the box.
Orient the box so the outermost holes are aligned with the
2 x 4 brace. The outermost holes will be used in Step 3B.
CAUTION: Do not use a lubricant on screws.
SINCE 1 8 8 6
®
A.
B.
A.
A.
B.
INSTALLATION INSTRUCTIONS FOR
HUNTER ORIGINAL CEILING FANS
1
41121-01 9/95 ©1993 HUNTER FAN CO.™
CAUTION:
Read this entire instruction manual thoroughly before
beginning installation and SAVE THESE INSTRUCTIONS.
To avoid possible shock, BE CERTAIN ELECTRICITY IS
SHUT OFF AT MAIN PANEL BEFORE WIRING. Always
turn power off at main panel before servicing your fan or
installing accessories.
All wiring must be in accordance with national and local
electrical codes. If you are unfamiliar with wiring, you
should use a qualified electrician.
To reduce the risk of personal injury, install the fan only
to the building structure according to these instructions,
and use only the hardware supplied.
NEVER REST THE FAN ON THE SWITCH HOUSING. As
you prepare the fan for installation, let the motor rest in
the liner in which it was packed.
Be sure to put full contents of oil tube in fan according to
instructions.
If this fan is used as a replacement for an Original Old-
Tyme non-reversible fan, it must be installed per
instructions included with this fan. DO NOT HANG ON
SINGLE J” HOOK. Failure to follow these instructions
could result in fan falling.
To reduce the risk of noise do not use a solid-state
speed control with this fan. Use Hunter controls only.
Do not use an abrasive cleaner on the fan. A mild
detergent will clean and restore most units to their
original beauty.
1.
2.
3.
4.
5.
6.
7.
8.
84" min. to floor
24" clearance
Fig. 1
Oil
Rubber Bushing
with Pin
Canopy Screws
Blade Screws
Blade Assembly Screws
Bracket Screws
Hanger Bracket Assembly
Pipe Nipple
in Motor Carton
Bracket
Fig. 2
12" minimum
Drill (2) 11/64" diameter holes through the outermost holes in
the box 2" deep into the cross brace. These holes are for the
bracket screws.
Use the (2) bracket screws to secure the hanger bracket to
the joist as shown in Figure 4. Install rubber bushing in hang-
er bracket before assembling the parts to the ceiling joist. Do
not use lubricant on the screw threads. For an alternate
bracket that fits inside a surface-mounted box, cut 1" off
each end of the bracket supplied.
Step 4: Hanging your fan
CAUTION: BE SURE TO TIGHTEN THE PIPE NIPPLE INTO THE
FAN, AND THE HANGER BRACKET ONTO THE PIPE, AND
TIGHTEN THE 2 SET SCREWS, AS DESCRIBED IN STEP B, TO
PREVENT THE FAN FROM FALLING.
CAUTION: YOUR FAN MAY WEIGHT UP TO 50 LBS. ALL OF
THE FOLLOWING STEPS MUST BE FOLLOWED IN ORDER TO
ENSURE A SECURE MOUNT ING . PERFORM ST EPS A
THROUGH D WITH MOTOR RESTING IN LINER FOR PROTEC-
TION.
Take hanger bracket from sack parts and pipe nipple. Feed
wires from the top of your motor through pipe.
Back out set screw in neck of fan
motor housing and hanger bracket
so pipe can be screwed in. Screw
the pipe into the fan until tight (at
least 41/2turns). Feed wire through
hanger bracket and screw hanger
bracket onto pipe until tight (at least
3 turns). Then use pliers to tighten
both hanger bracket and pipe
together. Tighten the set screw in
the mot or housing wit h pliers.
Securely tighten the set screw in the
hanger bracket. See Figure 5.
Be sure the pin is centered in the
rubber bushing.
See Figures 6 and 7.
Lift the fan by the motor housing,
hook the hanger bracket onto the
pin in the rubber bushing. Make
sure both ends of the pin are
outside the hanger bracket.
See Figure 9. FAILURE TO PER-
FORM THESE STEPS IN COR-
RECT ORDER MAY RESULT IN
FAN FALLING.
Step 5: Wiring instructions and canopy
installation
CAUTION: BE CERTAIN THAT ELECTRICITY IS TURNED OFF
AT THE MAIN PANEL BEFORE ANY WIRING IS DONE.
Before you do the final wiring, you should decide how you want
to control your fan—with pull cord, a wall switch or a speed con-
trol. At this point, you should also decide if you want to add a
light adaptor kit. Separate wiring instructions for Hunter
accessories are included in accessory packages.
Connect black electrical supply lead
to the black motor lead and the
black with white stripe motor lead
(See note). Connect the white elec-
trical supply lead to the white motor
lead. Connect ground wire to green
screw
on side of hanger bracket. See
Figure 8.
NOTE: If a separate wall switch will be used to control a
lighting accessory, connect the black wire with a white
stripe to the wall switch lead, following wiring instructions
included with the accessory. The wall switch must be a list-
ed general-use switch.
CAUTION: NO BARE WIRE OR WIRE STRANDS SHOULD
BE VISIBLE AFTER MAKING CONNECTIONS.
After making the wire connections, the wires should be
spread apart with the white and the green wires on one side
of the outlet box, and the black and black & white wires on
the other side of the box.
The splices should be turned upward and pushed carefully
up into the outlet box.
Canopy installation
Assemble canopy halves around pipe.
Screw together loosely using two
screws provided in parts bag. (Brass
and antique brass canopies are shipped
assembled.) Position canopy close to
ceiling. Tighten both assembly screws
and SCREW IN the canopy set screw.
See Figure 9. NOTE: If a Vaulted Ceiling
Mounting Kit is used, follow the can-
opy instructions provided with the kit.
Step 6: Lubrication
Adding oil
Your fan has been shipped without
oil in the motor. A 1-ounce tube of
high grade SAE 10 non-detergent oil
is packaged in the sack parts. All the
oil in the tube must be put into the
fan. Cut the tip off the tube and place the tube into the oil hole.
To avoid overflowing during filling, allow oil to gravity flow
about one minute to fill the oil reservoir. (It may be necessary
to puncture the tube to allow air in.) See Figure 10.
All wiring must conform to national and local codes which
may vary by locale.
A.
B.
C.
Fig. 3
D.
A.
B.
C.
2
41121-01 9/95 ©1993 HUNTER FAN CO.™
Fig. 4
Hanger
Bracket
Rubber
Bushing
Bracket
Screws
Rubber
Bushing
Bracket
Screws
Alternate Bracket
Hanger
Bracket
Fig. 5
Fig. 6
Set
Screw
Bushing
Pin
Fig 10
Fig 9
Set
Screw
Assembly
Screw
Fig. 8
Fig. 7
Bushing
Pin
Set Screws
Min.
84" to
floor
40mm x 80mm WOOD BRACE
CEILING
CEILING JOIST
OUTLET BOX M4 WOOD SCREW
& WASHER (2) REQUIRED

Produktspecifikationer

Varumärke: Hunter
Kategori: Fläkt
Modell: 23852

Behöver du hjälp?

Om du behöver hjälp med Hunter 23852 ställ en fråga nedan och andra användare kommer att svara dig




Fläkt Hunter Manualer

Fläkt Manualer

Nyaste Fläkt Manualer