Hunter Sentinel 59211 Bruksanvisning

Hunter Fläkt Sentinel 59211

Läs nedan 📖 manual på svenska för Hunter Sentinel 59211 (20 sidor) i kategorin Fläkt. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/20
www.HunterFan.com 1.888.830.1326
Table of Contents
Congratulations on purchasing
your new Hunter® ceiling fan! It will
provide comfort and performance
in your home or ofce for many
years. This installation and operation
manual contains complete
instructions for installing and
operating your fan.
We are proud of our work and
appreciate the opportunity to
supply you with the best ceiling fan
available anywhere in the world.
To register your fan, please visit:
www.HunterFan.com/register
Save your receipt for proof of purchase.
PA G E
5
PA G E
20
30 inches
7 feet
PA G E
2
What to Expect with
Your Installation Ceiling Bracket
Ladder
PA G E
3
Tools Needed
Troubleshooting
?
?
?
PA G E
18
Mounting Options
PA G E
6
PA G E
10
Wiring CanopyDownrod
PA G E
12
Blades
PA G E
13
PA G E
4
Remote Control
PA G E
17
Operation,
Maintenance & Cleaning
PA G E
15
Light Kit
PA G E
14
Switch Housing
1
M3599-01 • 02/09/16 • © 2016 Hunter Fan Company
www.HunterFan.com
1.888.830.1326
2
M3599-01 • 02/09/16 • © 2016 Hunter Fan Company
Know your wiring
If you are unfamiliar
with wiring, use a
qualied electrician.
You may need a
friend to help you.
Check box to see
fan weight
Assess location
30 inches
from blade tip
to nearest wall
or obstruction 7 feet
from bottom
edge of blade
to the oor
Select a downrod lengthAssess ceiling angle
Must be able to
secure the fan to
building structure or
fan-rated outlet box
1
2
3
Standard Downrod
for ceilings 8-10 feet high
Shorter Downrod
for fans installed close to ceiling
Longer Downrod
for ceilings 10 feet or higher
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
w.1 - To reduce the risk of re, electrical shock, or personal injury,
mount fan directly from building structure and/or an outlet box marked
acceptable for fan support of 70 lbs (31.8 kg) and use the mounting
screws provided with the outlet box.
w.2 - To avoid possible electrical shock, before installing or servicing your
fan, disconnect the power by turning off the circuit breakers to the outlet
box and associated wall switch location. If you cannot lock the circuit
breakers in the off position, securely fasten a prominent warning device,
such as a tag, to the service panel.
w.3 - To reduce the risk of re, electrical shock, or motor damage, use only
Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the blade brackets when
installing the blade brackets, balancing the blades, or cleaning the fan. Do not
insert foreign objects in between rotating fan blades.
c.1 - All wiring must be in accordance with national and local electrical codes
ANSI/NFPA 70. If you are unfamiliar with wiring, use a qualied electrician.
c.2 - Use only Hunter replacement parts.
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in
a residential installation. This equipment generates, uses and can radiate
radio frequency energy and if not installed and used in accordance with the
instructions may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off
and on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
Caution: modications not approved by the party responsible for compliance
could void user’s authority to operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.
Read and Save These Instructions
This product conforms to UL Standard 507.
WARNINGS
CAUTIONS
What to Expect with Your Installation
www.HunterFan.com
1.888.830.1326
Tools Needed
Ladder
Power Drill
(optional)
9/64” Drill Bit
(optional)
ScrewdriversPliers Wire Strippers
If mounting to a support structure, you will also need these tools.
3
M3599-01 • 02/09/16 • © 2016 Hunter Fan Company