Jotul F 500 V2 Oslo CF Bruksanvisning
Läs nedan 📖 manual på svenska för Jotul F 500 V2 Oslo CF (26 sidor) i kategorin Spis. Denna guide var användbar för 9 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/26
Jøtul F 500
Non-catalytic Wood Stove
Classic and Clean Face Models
Installation and Operating Instructions
for the United States and Canada
Jøtul F 500
The Jøtul F 500 non-catalytic stove is
listed to burn solid wood only. Do not
burn any other fuels.
Read this entire manual before you
install and use this appliance.
Save these instructions for future
reference and make them available
to anyone using or servicing the
fireplace insert.
This wood heater requires periodic
inspection and repair for proper
operation. See this manual for
specific maintenance information.
It is against federal regulations to
operate this wood heater in a manner
inconsistent with the operating
instructions in this owner’s manual.
Classic
Clean Face
2
139681_R06 F 500 Oslo 1/20
Table of Contents
Combustion Specifications,
Building Codes,
Safety Notices 3 ..................................................................................
1.0 Installation
1.1 Assembly before Installation 4 ..........................
1.2 Chimney Connector 4 ..........................................
2.0 Chimney Requirements
2.1 Masonry Chimneys 5 ............................................
2.2 Prefabricated Chimneys 5 ..................................
2.3 Chimney Height 5 .................................................
2.4 Wall Pass-throughs 5 ...........................................
3.0 Connecting to the Chimney
3.1 Masonry Chimney Thimbles 6 ....................................
3.2 Hearthmount into a Masonry Fireplace 6 ...............
3.3 Prefabricated Chimneys............................................ 6
4.0 Clearances to combustibles
4.1 Floor Protection 7 ..........................................................
4,2 Clearances to Walls and Ceilings 7 ...........................
4.3 Using Shields to reduce Clearances 7 ......................
4.4 Alcove Installation 8 .................................................................
4.5 MobileHome Installation 8 .....................................................
5.0 Operation
5.1 Combustion Efficiency 8 ..............................................
5.2 CO Emissions 8 ..............................................................
5.3 Wood Fuel and Performance 8 .................................
5.4 Air Flow and Control 8 .................................................
5.5 Break-in Procedure 9 ...................................................
5.6 Starting and Maintaining a Fire 9 ........................................
5.7 Creosote Formation and Removal 10 .........................
5.8 Adding Fuel 10 .................................................................
6.0 Maintenance
6.1 Annual Stove Inspection 11 .........................................
6.2 Ash Removal 11 ..............................................................
6.3 Chimney System 11 ......................................................
6.4 Enamel Care 11 .............................................................
6.5 Glass Care 11 ...................................................................
6.6 Glass Replacement 11 ...................................................
6.7 Gaskets 11 ........................................................................
7.0 Accessories
Firescreen 13 ............................................................................
Outside Air Kit 13 ....................................................................
Floor Bracket Kit 13 ................................................................
Rear Heatshield 13 ..................................................................
Bottom Heatshield 13 ............................................................
Stove -Top Thermometer ................................................. 13
Side Door Lock Kit 13 ..............................................................
8.0 Illustrations
Figures 14-16 ..............................................................................................
Clearance Chart and Diagrams 17-18 ..................................................
Parts Schematic and Listing 19-20 ........................................................
Appendix A (alternate floor protection)...................................21
9.0 Warranty Statement .............................................22
Standards
The Jøtul F solid fuel heater has been tested and listed to : 500
U.S. Standards: ANSI/UL 737 and ANSI/UL 1482.
Canadian Standards:
CAN/ULC-S627-M and CAN/ULC-S628-M00 93
Certified Safety Tests performed by:
Intertek Testing Services, Middleton,
Wisconsin U.S.A.
Manufactured by:
Jøtul North America, Inc.
55 Hutcherson Drive
Gorham, Maine 04038, USA
and
Jøtul AS, P.O. Box 1411, Fredrikstad, Norway
Check Building Codes
WARNING !
THIS WOOD HEATER HAS A MANUFACTURER-
SET MINIMUM LOW BURN RATE THAT MUST
NOT BE ALTERED. IT IS AGAINST FEDERAL
REGULATIONS TO ALTER THIS SETTING
OR OTHERWISE OPERATE THIS WOOD
HEATER IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THIS MANUAL.
This heater meets the 2015 U.S.
Environmental Protection Agency’s
emission limits for wood heaters
manufactured after May 15, 2015.
This heater may not be sold
after May 15, 2020.
A French language version of fhis manual is available to
download at www. jotul. ca.
Télécharger la version française de ce manuel à l’adresse www.
jotul.ca.
NOTE: It is normal for a new, painted stove to emit
odor and smoke during initial fires, depending
upon temperatures over time. This is caused
by the curing of high temperature paint and
manufacturing materials. This condition can
be alleviated by opening a window or door to
provide additional ventilation. See Break-in
Procedure on page 9 for details.
3
139681_R06 F 500 Oslo 1/20
Whe n installing, operating and maintaining your
Jøtul F 500 woodstove, follow the guidelines presented in
these instructions, and make them available to anyone using or
servicing the stove.
Your city, town, county or province may require a building permit
to install a solid fuel burning appliance.
In the U.S., the National Fire Protection Association’s Code,
NFPA 211, Standards for Chimneys, Fireplaces, Vents and Solid Fuel
Burning Appliances, or similar regulations, may apply to the
installation of a solid fuel burning appliance in your area.
In Canada, the guideline is established by the CSA Standard, CAN/
CSA-B365-M93, Installation Code for Solid-Fuel-Burning Appliances
and Equipment.
Always consult your local building inspector or authority having
jurisdiction to determine what regulations apply in your area.
See Sect. 5.0 of this manual for important information
regarding the safe, proper, and most efficient operation
of your stove.
Safety Notices
• BURN SOLID, NATURAL WOOD FUEL ONLY. DO NOT BURN ANY
OTHER FUEL.
• DO NOT USE CHEMICALS OR FLUIDS TO START A FIRE. DO NOT
BURN GARBAGE OR FLAMMABLE FUELS.
• DO NOT USE A GRATE OR ELEVATE THE FIRE. BUILD THE FIRE
DIRECTLY ON THE HEARTH.
• IF THIS ROOM HEATER IS NOT PROPERLY INSTALLED, A HOUSE
FIRE MAY RESULT. TO REDUCE THE RISK OF FIRE, FOLLOW THE
INSTRUCTIONS IN THIS MANUAL. FAILURE TO FOLLOW THESE
INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY
INJURY, OR LOSS OF LIFE.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC-
TIONS AND INSTALLATION INSPECTION REQUIREMENTS IN
YOUR AREA.
• ANY EXISTING CHIMNEY SYSTEM MUST BE INSPECTED BEFORE
INSTALLATION OF THIS APPLIANCE.
• DO NOT CONNECT THIS STOVE TO ANY AIR DISTRIBUTION
DUCT OR SYSTEM.
• EXTREMELY HOT WHILE IN OPERATION! KEEP CHILDREN,
CLOTHING, AND FURNITURE AWAY. CONTACT WILL CAUSE SKIN
BURNS. USE A CHILD GUARD SCREEN TO PREVENT ACCIDENTAL
CONTACT BY SMALL CHILDREN.
• INSTALL SMOKE DETECTORS IN THE LIVING AREA AND BED-
ROOMS OF YOUR HOME. TEST THEM REGULARLY AND INSTALL
FRESH BATTERIES TWICE ANNUALLY.
WHEN INSTALLED IN THE SAME ROOM AS THE STOVE, A SMOKE
OR CARBON MONOXIDE DETECTOR SHOULD BE LOCATED AS
FAR FROM THE STOVE AS POSSIBLE TO PREVENT THE ALARM
SOUNDING WHEN ADDING FUEL.
• Avoid creating a low pressure condition in the room where
the stove is operating. Be aware that operation of an exhaust
fan or clothes dryer can create a low pressure area and conse-
quently promote flow reversal through the stove and chimney
system. In some cases, the optional Outside Air Kit #154335
can be used to alleviate this condition. The chimney and build-
ing, however, always work together as a system - provision of
outside air, directly or indirectly to an atmospherically vented
appliance will not guarantee proper chimney performance.
Consult your local Jøtul authorized dealer regarding specific
installation/performance issues.
• Jøtul strongly recommends that this stove be installed by
a professional solid fuel technician, or that you consult one
if you do the work yourself. Also, consult your insurance
company regarding any other specific requirements.
Combustion Specifications
Jøtul F 500
Heat Output Range:1 12,000 to 34,700 BTU/hr.
Max. Heat Output: 70,000 BTU/hr.
Heating Capacity:2 Up to 2000 sq. ft.
Maximum Burn Time:2 Up to 9 hours
EPA Efficiency:3 HHV: 73.94% LHV: 79.88%
CO Emissions:4 112.22 g/hr
Pariculate Emissions:5 3.2 g/hr
Fuel: Up to 24” Logs (609 mm)
.
1 results are determined during specific Heat Output Range
emissions tests established by the EPA.
The Maximum Heat Output value is representative of a more
frequent re-fueling cycle than specified in the EPA High Heat
Output test method.
2 Heating Capacity and Maximum Burn Time will vary depend-
ing on design of home, climate, wood type and operation
3 EPA Validated Efficiency:
High Heat Value and Low Heat Value are obtained per CSA
B415.1-10 test method. HHV calculation encompasses all
products of combustion, including H2O condensation. LHV
calculation includes H2O in its vapor state. Simply put, HHV
assumes all the water component is in a liquid state (con-
densed) at the end of combustion and that heat recovered
from condensation can be put to use.
4 Carbon Monoxide Emissions rate results from Test Method
CSA B415.1-10.
5.
Particulate Emissions rate is obtained using EPA Test Method
28-5H.
Produktspecifikationer
Varumärke: | Jotul |
Kategori: | Spis |
Modell: | F 500 V2 Oslo CF |
Behöver du hjälp?
Om du behöver hjälp med Jotul F 500 V2 Oslo CF ställ en fråga nedan och andra användare kommer att svara dig
Spis Jotul Manualer
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
25 September 2024
Spis Manualer
- Spis Zibro
- Spis Electrolux
- Spis Bosch
- Spis AEG
- Spis Bauknecht
- Spis BEKO
- Spis Honeywell
- Spis Inventum
- Spis Miele
- Spis Quigg
- Spis Siemens
- Spis Aduro
- Spis Amica
- Spis Animo
- Spis AKO
- Spis Argo
- Spis Altech
- Spis Artel
- Spis Invicta
- Spis Bartscher
- Spis Toolland
- Spis Alde
- Spis Eurom
- Spis GE
- Spis Orbegozo
- Spis Bertazzoni
- Spis Klarstein
- Spis Severin
- Spis Smeg
- Spis Telefunken
- Spis Neff
- Spis Silvercrest
- Spis Baumatic
- Spis Nedis
- Spis Black And Decker
- Spis KitchenAid
- Spis Tristar
- Spis Domo
- Spis Progress
- Spis Rowenta
- Spis Rika
- Spis Manta
- Spis Cylinda
- Spis Bestron
- Spis ECG
- Spis Pelgrim
- Spis Jata
- Spis Swan
- Spis Emerio
- Spis Scarlett
- Spis Taurus
- Spis Constructa
- Spis Sencor
- Spis Midea
- Spis Concept
- Spis Svan
- Spis Logik
- Spis Anslut
- Spis Elro
- Spis Climastar
- Spis EWT
- Spis Ernesto
- Spis Truma
- Spis Mellerware
- Spis Nestor Martin
- Spis Eldom
- Spis Philco
- Spis Stiebel Eltron
- Spis Infiniton
- Spis Buderus
- Spis Dimplex
- Spis Suntec
- Spis Profile
- Spis Perel
- Spis Steba
- Spis Zibro Kamin
- Spis Proline
- Spis Cola
- Spis Zelmer
- Spis Ardes
- Spis Piazzetta
- Spis Cotech
- Spis Ufesa
- Spis Wilfa
- Spis Olimpia Splendid
- Spis Trotec
- Spis Lofra
- Spis Wamsler
- Spis Qlima
- Spis Duux
- Spis Imetec
- Spis Alpatec
- Spis Jocel
- Spis M-System
- Spis Primo
- Spis Dovre
- Spis Atlantic
- Spis Aurora
- Spis V-Zug
- Spis Trumatic
- Spis Tectro
- Spis Mill
- Spis Orion
- Spis Tesy
- Spis Essentiel B
- Spis AWB
- Spis Faber
- Spis Thorma
- Spis Palazzetti
- Spis Fuave
- Spis CaterChef
- Spis Harvia
- Spis Basetech
- Spis Bimar
- Spis Edilkamin
- Spis Superior
- Spis La Nordica
- Spis Day
- Spis Radson
- Spis Fuxtec
- Spis Kero
- Spis Nobo
- Spis Cadel
- Spis Vornado
- Spis Hwam
- Spis Coleman
- Spis Extraflame
- Spis Toyotomi
- Spis Thermor
- Spis Livington
- Spis Kalorik
- Spis Livin Flame
- Spis Max Blank
- Spis Spartherm
- Spis Ecoforest
- Spis Voltomat Heating
- Spis Qlima - Zibro
- Spis Brandson
- Spis Ecoteck
- Spis Oranier
- Spis Duracraft
- Spis Bocal
- Spis Haas-Sohn
- Spis Austroflamm
- Spis Thermorossi
- Spis Saey
- Spis Eva Calor
- Spis Nordic Fire
- Spis Flam
- Spis Haas+Sohn
- Spis Norsk Kleber
- Spis Kabola
- Spis Ganz
- Spis Olympia Fires
- Spis Wanders
- Spis Kago
- Spis Hartig Helling
- Spis Kerosun
- Spis Morso
- Spis Olsberg
- Spis Supra
- Spis MCZ
- Spis JennAir
- Spis Rais
- Spis Global
- Spis DRU
- Spis PVG
- Spis Prem-i-air
- Spis Burley
- Spis Ulma
- Spis Panadero
- Spis Justus
- Spis Xeoos
- Spis Horus
- Spis Migros
- Spis Zen Fires
- Spis Ravelli
- Spis Scan
- Spis Reny
- Spis Hearthstone
- Spis Kratki
- Spis Flandria
- Spis Barbas
- Spis Dik Geurts
- Spis ATTACK
- Spis Toyoset
- Spis Thermocet
- Spis Surdiac
- Spis Yamazen
Nyaste Spis Manualer
27 Oktober 2024
26 Oktober 2024
23 Oktober 2024
23 Oktober 2024
23 Oktober 2024
22 Oktober 2024
20 Oktober 2024
19 Oktober 2024
19 Oktober 2024
19 Oktober 2024