Kern ORA 1WB Bruksanvisning
Kern
Mätutrustning
ORA 1WB
Läs nedan 📖 manual på svenska för Kern ORA 1WB (2 sidor) i kategorin Mätutrustning. Denna guide var användbar för 2 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/2
1
2
CONTENT S
1 Technical data.................................................................................................1
2 Description......................................................................................................2
3 General information 3 .......................................................................................
3.1 Intended use 3 ...................................................................................................
3.2 Warranty..........................................................................................................3
4 Basic safety information 4 ...............................................................................
4.1 Follow the instructions in the operating manual 4 .......................................
4.2 Warning .......................................................................................................4-5
5 Supplied items 5 ................................................................................................
6 Before the first use 6 ........................................................................................
7 Use/measurement.........................................................................................6
7.1 Zero point calibration 7-8 ................................................................................
7.2 Additional advice 9 ............................................................................................
7.3 Measuring procedure 9-10 ..............................................................................
8 Cleaning and maintenance 11 .........................................................................
9 Storage .........................................................................................................11
10 Service.......................................................................................................... 12
11 Disposal ........................................................................................................ 12
12 Additional information 12 ................................................................................
13 Brix to refractive index (nD) conversion table 13 ............................................
14 Annex ........................................................................................................... 14
1. Technical data
Models
K ERN
Measuring range
and Scales
Scale gradua-
tions Accuracy
Dimensions
Product
Net
weight
ORA 1 WBWA/
0-140°Oe
0-25°KMW (Babo)
0-32% Brix
1°Oe
0,25°KMW (Babo)
0,2% Brix
178x40x40mm 0,145kg
ORA 3 WBWA/ 30-140°Oe
0-32% Brix
1°Oe
0,2% Brix 178x40x40mm 0,145kg
ORA 7 WBWA/
0-32% Brix
30-140°Oe
0-25°KMW (Babo)
0,2% Brix
1°Oe
0,2°KMW (Babo)
178x40x40mm 0,145kg
198x40x40mm 0,155kg
KERN & Sohn GmbH
Ziegelei 1
D-72336 Balingen
E-Mail: info@kern-sohn.com
Tel: +49-[0]7433-9933-0
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
GB
2. Description
1. Prism cover
2. Prism surface
3. Adjustment screw
4. Eyepiece with rubber eyeshade
5. Diopter adjustment ring
6. Optical tubes with rubber grip
Example scale on
ORA 1 WB
2
4
5
3
6
1
Operating manual
Analogue refractometer
Version 1. 0 / 2012 8 8
7. Storage box
8. Pipette
9. Refractometer
10. Calibration liquid
(Distilled water)
11. Adjustment tool
12. Cleaning cloth
6
5
3
4
3. General information
3.1 Intended use
The refractometer is a measuring instrument for determining the refractive index of
transparent substances in the liquid or the solid state. It is used to observe the
behaviour of light as it passes from a prism with known properties to the substance
being tested.
Use of the refractometer for other purposes is contrary to its intended use and may
be hazardous. The manufacturer shall not be liable for any damages caused
by improper use.
3.2 Warranty
The warranty shall be void in the event of:
▸ Failure to observe the instructions in the operating manual
▸ Use for purposes other than those described
▸ Modifications or opening the device housing
▸ Mechanical damage and/or damage resulting from media, liquids,
natural wear and tear
4. Basic safety information
4.1 Follow the instructions in the operating manual
▸ Carefully read through the operating manual even if you have prior
experience with KERN refractometers.
▸ Every language version includes a non-authoritative translation.
The original German document is the definitive version.
4.2 Warning
▸ Do not let acids come into contact with skin or eyes. If acid comes into contact
with skin, flush with copious amounts of water. Shower if larger areas of skin are
affected.
▸ If acid comes into contact with eyes, keep the eyelid open and flush the eye with
running lukewarm water from the outer corner to the inner corner. Flush eyes for
at least 15 minutes. Then consult a doctor or ophthalmologist immediately.
▸ Thoroughly clean the refractometer aer each use.
▸ The refractometer must not be exposed to extreme temperatures, high
mechanical stresses, strong direct sunlight or high humidity.
▸ This refractometer is not a toy. Keep out of reach of children.
▸ Make sure that you will not be hit by anything else while you are using the
refractometer, as this could cause serious eye injuries
▸ The rubber eyeshade may cause irritation when in prolonged contact with the
skin. If this happens, consult your doctor.
▸ Do not touch the lenses with your fingers.
6. Before the first use
Remove the protective film (if present) from the prism surface [2] and check that
the rubber eye-cup
[4] is fitted correctly.
7. Use/measurement
The refractometer can be used to quickly and accurately determine the refractive
index of transparent substances, liquid or solid ones. To ensure correct measure-
ment, the measuring device should be adjusted before measurements are carried
out. Please make sure your hands are dry before handling the measuring device.
5. Supplied items
Aer unpacking and before using the device for the first time, check that all
listed parts have been supplied. Replace damaged or faulty parts immediately
and do not put them into operation.
▸ Refractometer
▸ Storage box
▸ Pipette
▸ Adjustment tool
▸ Cleaning cloth
▸ alibration Cliquid (Distilled water)
KERN ORA 1 WA/WB Wine
ORA 3 WA/WB Wine
ORA 7 WA/WB Wine
ORA 1 AB / 2 AB Alcohol
ORA 1AB (Volume)
ORA 2AB (Mass)
0-50 % (v/v) / (w/w)
50-80 % (v/v) / (w/w)
1 % (v/v) / (w/w)
2,5 % (v/v) / (w/w)
7
14
8
9
10
12
11
13
7.1 Zero point calibration
▸ Hold up the refractometer against a sufficiently bright light source and look through
the eyepiece [5], holding the rubber eyeshade [4] closely against your eye/glasses.
▸ Rotate the eyepiece [5] to adjust it for your eyesight, until you can see the scale
sharply.
▸ Open the prism cover [1
].
▸ Thoroughly clean the prism [2] and the underside of the prism cover [1] using a so
cloth or soft paper (with alcohol if necessary) and wipe dry.
▸ Now apply a few drops of the calibration liquid
[10] onto the prism surface [2].
▸ lose the prism cover C[1]. The amount of fluid should be sufficient to moisten most
of the prism surface. There should not be any air bubbles between the measuring
prism [2] and prism cover [1]
.
▸ Wait about 30 seconds to allow the temperatures of the fluid and prism to
equalise.
▸ Look through the eyepiece
[4] while pointing the refractometer‘s prism surface [2]
at a bright light source.
▸ Through the eyepiece
[4], you will see a bright and a blue field. The boundary line
between them shows the value on the scale which is also visible measured
through the eyepiece [4]
.
▸ Use the supplied adjustment tool
[11] to turn the adjustment screw [
3]
behind
the prism surface [2
]
(under the rubber cap ), and adjust the scale so that the
measuring device is optimally set up by moving the boundary line upwards or downwards.
Calibration value ORA 1WA/1WB: 0 % (Brix) / 0 °Oe (Oechsle) / 0 °KMW (KMW Babo)
Calibration value ORA 3WA/3WB: 0 % (Brix)
Calibration value ORA 7WA/7WB: 0 % (Brix) / 0 °Oe (Oechsle) / 0 °KMW (KMW Babo)
Calibration value ORA 1AB / 2AB: 0 % (v/v) / (w/w)
▸ Repeat step 4 (cleaning)
.
Important!
The ambient/room temperature and the sample temperature influ-ence the
refractometer measuring result. The scales of the refractometer models,
which have " B " in its name, are designed for an ambient W / AB
7.2 Additional advice
It is important that the samples being measured are representative samples. For
samples that evaporate easily, measurements should be carried out quickly. The
samples should be at the same temperature as the measuring instrument in order
to achieve an accurate result.
7.3 Measuring procedure
▸ Make sure your hands are dry before handling the refractometer.
▸ Open the prism cover [1]
and use the supplied pipette [8] to apply a few drops of
the sample liquid
[8
] onto the prism surface [2]. Close the prism cover
[1]. Spread
the liquid evenly by pressing down on the prism cover [1] and elimi-nate any air
bubbles present.⇨
▸ Hold the device horizontally and wait about 30 seconds
(
for optimal tempera-ture
equalisation between the sample and device
).
▸ View the measurement scale through the eyepiece
[4]. Point the prism surface [2]
of the refractometer at a bright light source while doing this.
▸ Rotate the adjustment ring
[5] on the eyepiece [
4] to adjust the focus.
▸ The boundary line will move on the measurement scale depending on the concen-
tration. This bright/dark boundary line shows the result on the scale.
▸ If the temperature deviates from +20 °C , and a refractometer without ATC is used
correct the measured result using the corresponding value from the temperature
correction table [13
].
▸ Carefully clean the supplied pipette
[8] and the refractometer aer carrying out
the measurement.
Important!
Aer every measurement, use a lint-free, absorbent cloth to remove
the fluids from the prism surface [2] and prism cover [1]. Then
carefully clean the prism and prism cover using a cloth moistened
with water or if necessary alcohol, and dry both parts using a so,
dry and lint-free cloth. Avoid rubbing the prism [
2]
.
9
BRIX
Refractive
index BRIX
Refractive
index BRIX
Refractive
index
%
nD
%
nD
%
nD
0 1.33299 30 1.38115 60 1.44193
1
1.33442
31
1.38296
61
1.44420
2 1.33586 32 1.38478 62 1.44650
3 1.33732 33 1.38661 63 1.44881
4 1.33879 34 1.38846 64 1.45113
5 1.34026 35 1.39032 65 1.45348
6 1.34175 36 1.39220 66 1.45584
7 1.34325 37 1.39409 67 1.45822
8 1.34476 38 1.39600 68 1.46061
9 1.34629 39 1.39792 69 1.46303
10 1.34782 40 1.39986 70 1.46546
11 1.34937 41 1.40181 71 1.46792
12 1.35093 42 1.40378 72 1.47037
13 43 1.40576 73 1.35250 1.47285
14 1.35408 44 1.40776 74 1.47535
15 1.35568 45 1.40978 75 1.47787
16 46 1.41181 76 .48040 1.35729 1
17 1.35891 47 1.41385 77 1.48295
18 1.36054 48 1.41592 78 1.48552
19 49 1.41799 79 1.4881 1.36218
20 1.36384 50 1.42009 80 1.49071
21 1.36551 51 1.42220 81 1.49333
22 1.36720 52 1.42432 82 1.49597
23
1.36889
53
1.42647
83
1.49862
24 1.37060 54 1.42862 84 1.50129
25 1.37233 55 1.43080 85 1.50398
26 1.37406 56 1.43299
27 1.37582 57 1.43520
28 1.37758 58 1.43743
29 1.37936 59 1.43967
!
8. Cleaning and maintenance
Clean the refractometer using a so, lint-free cloth moistened with either water
or, if necessary, alcohol. Do not use any aggressive or abrasive cleaning agents.
Never immerse the device in water or hold it under running water. Never handle the
device with wet or damp hands.
Never touch the measuring prism [2] with hard tools made from plastic, wood,
rubber, metal, glass etc. Hard objects can quickly damage the relatively so prism
glass, resulting in measurement errors.
The refractometer is maintenance-free.
Cleaning should be carried out immediately before and aer each use of the refrac-
tometer to maximise its life and optimise measurement results.
9. Storage
Store the refractometer in a dry, non-corrosive environment, preferably
between 10 °C and 30 °C.
10. Service
Aer reading this operating manual, if you have any questions about setting up
or using the refractometer, or if any unexpected problem occurs, please contact
your dealer. The device housing may only be opened by trained service technicians
authorised by KERN.
11. Disposal
The packaging consists of environmentally friendly materials which can be disposed
of via local recycling facilities.
The device and storage box should be disposed of by the operator in accordance
with applicable national or regional regulations at the place of use.
12. Additional information
The product may differ slightly from the illustrations. Avoid exposing the refracto-
meter to direct sunlight. Never bring the refractometer into contact with solvents.
13. Brix to refractive index (nD) conversion table
Data from „ICUMSA“ International Commission for Uniform Methods
of Sugar Analysis, at 20 °C and 589 nm wavelength.
!
% Brix
reading
0.0 5.0 10.0 15.0 20.0 25.0 30.0 35.0 40.0 45.0 50.0 55.0 60.0 65.0 70.0 75.0 80.0 85.0
Temperature °C
10.0 - - - - - - - - - - - - - - - - - -0.53 0.56 0.59 0.62 0.65 0.67 0.69 0.71 0.72 0.73 0.74 0.75 0.75 0.75 0.75 0.75 0.74 0.73
11.0 - - - - - - -0 - - - - - - - - - - -0.49 0.52 0.54 0.57 0.59 0.61 .63 0.64 0.65 0.66 0.67 0.68 0.68 0.68 0.68 0.67 0.67 0.66
12.0 - - - - - - - - - - - - - - - - - -0.44 0.47 0.49 0.51 0.53 0.55 0.56 0.57 0.58 0.59 0.60 0.60 0.61 0.61 0.60 0.60 0.60 0.59
13.0 - - - - - - - - - - - 3 - - - - - - -0.40 0.41 0.43 0.45 0.47 0.48 0.50 0.51 0.52 0.52 0.5 0.53 0.53 0.53 0.53 0.53 0.52 0.52
14.0 - - - - - - - - - - - - - - - - - -0.34 0.36 0.38 0.39 0.40 0.42 0.43 0.44 0.44 0.45 0.45 0.46 0.46 0.46 0.46 0.45 0.45 0.44
15.0 - - - - - - - - - - - - - - - - - -0.29 0.31 0.32 0.33 0.34 0.35 0.36 0.37 0.37 0.38 0.38 0.38 0.38 0.38 0.38 0.38 0.37 0.37
16.0 - - - - - - - - - - - - - - - - - -0.24 0.25 0.26 0.27 0.28 0.28 0.29 0.30 0.30 0.30 0.31 0.31 0.31 0.31 0.31 0.30 0.30 0.30
17.0 - - - - - - - - - - - - - - - - - -0.18 0.19 0.20 0.20 0.21 0.21 0.22 0.22 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.23 0.22
18.0 - - - - - - - - - - - - - - - - - -0.12 0.13 0.13 0.14 0.14 0.14 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15 0.15
19.0 - - - - - - - - - - - - - - - - - -0.06 0.06 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07
20.0 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
21.0 0.06 0.07 0.07 0.07 0.07 0.07 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.08 0.07
22.0 0.13 0.14 0.14 0.14 0.15 0.15 0.15 0.15 0.16 0.16 0.16 0.16 0.16 0.16 0.15 0.15 0.15 0.15
23.0 0.20 0.21 0.21 0.22 0.22 0.23 0.23 0.23 0.23 0.24 0.24 0.24 0.24 0.23 0.23 0.23 0.23 0.22
24.0 0.27 0.28 0.29 0.29 0.30 0.30 0.31 0.31 0.31 0.32 0.32 0.32 0.32 0.31 0.31 0.31 0.30 0.30
25.0 0.34 0.35 0.36 0.37 0.38 0.38 0.39 0.39 0.40 0.40 0.40 0.40 0.40 0.39 0.39 0.39 0.38 0.37
26.0 0.42 0.43 0.44 0.45 0.46 0.46 0.47 0.47 0.48 0.48 0.48 0.48 0.48 0.47 0.47 0.46 0.46 0.46
27.0 0.50 0.51 0.52 0.53 0.54 0.55 0.55 0.56 0.56 0.56 0.56 0.56 0.56 0.55 0.55 0.54 0.53 0.52
28.0 0.58 0.59 0.60 0.61 0.62 0.63 0.64 0.64 0.64 0.65 0.65 0.64 0.64 0.64 0.63 0.62 0.61 0.60
29.0 0.66 0.67 0.68 0.69 0.70 0.71 0.72 0.73 0.73 0.73 0.73 0.73 0.72 0.72 0.71 0.70 0.69 0.68
30.0 0.74 0.75 0.77 0.78 0.79 0.80 0.81 0.81 0.81 0.82 0.81 0.81 0.81 0.80 0.79 0.78 0.75 0 .77
14. Annex
Table 1: International Temperature Correction Table for °Brix (
% sugar gradient)
Correct the result by the following values
(refractometer must be correctly
adjusted at 20 °C
).
temperature of +20 °C! If the measurements are carried out at a temperature other than +20 °C,
the results must be correspondingly corrected. A correction table can be found in the annex,
Point 14. Refractometer models, which have " A" in its name, are equipped with an automatic W
temperature compensation (ATC). Between +10°C and +30°C measurement differences due to
temperature changes are automatically compensated.
Produktspecifikationer
Varumärke: | Kern |
Kategori: | Mätutrustning |
Modell: | ORA 1WB |
Behöver du hjälp?
Om du behöver hjälp med Kern ORA 1WB ställ en fråga nedan och andra användare kommer att svara dig
Mätutrustning Kern Manualer
17 December 2024
25 Oktober 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
26 September 2024
Mätutrustning Manualer
- Mätutrustning Bosch
- Mätutrustning Panasonic
- Mätutrustning DeWalt
- Mätutrustning Fysic
- Mätutrustning Honeywell
- Mätutrustning Pioneer
- Mätutrustning Albrecht
- Mätutrustning Alecto
- Mätutrustning Amprobe
- Mätutrustning Nedis
- Mätutrustning Pyle
- Mätutrustning Yato
- Mätutrustning Lanaform
- Mätutrustning Megasat
- Mätutrustning Meec Tools
- Mätutrustning Milwaukee
- Mätutrustning Extech
- Mätutrustning Victron Energy
- Mätutrustning Hazet
- Mätutrustning Metrix
- Mätutrustning Benning
- Mätutrustning Einhell
- Mätutrustning Voltcraft
- Mätutrustning Midland
- Mätutrustning Mitsubishi
- Mätutrustning Velleman
- Mätutrustning Vemer
- Mätutrustning Technics
- Mätutrustning Perel
- Mätutrustning Burg-Wachter
- Mätutrustning Kyoritsu
- Mätutrustning IFM
- Mätutrustning Ideal
- Mätutrustning Flir
- Mätutrustning Homedics
- Mätutrustning Grohe
- Mätutrustning Technoline
- Mätutrustning Digitus
- Mätutrustning Soler And Palau
- Mätutrustning Continental Edison
- Mätutrustning Rossmax
- Mätutrustning Carrier
- Mätutrustning Testboy
- Mätutrustning Goclever
- Mätutrustning Trotec
- Mätutrustning LaCie
- Mätutrustning Danfoss
- Mätutrustning AS - Schwabe
- Mätutrustning Hager
- Mätutrustning Bresser
- Mätutrustning TFA
- Mätutrustning Owon
- Mätutrustning Flex
- Mätutrustning Finder
- Mätutrustning Fluke
- Mätutrustning Fantini Cosmi
- Mätutrustning Eltako
- Mätutrustning EBERLE
- Mätutrustning Basetech
- Mätutrustning Stabila
- Mätutrustning Steinberg
- Mätutrustning Be Cool
- Mätutrustning Laserliner
- Mätutrustning Wentronic
- Mätutrustning Comark
- Mätutrustning REV
- Mätutrustning Testo
- Mätutrustning Sauter
- Mätutrustning Clean Air Optima
- Mätutrustning Bruder Mannesmann
- Mätutrustning Livington
- Mätutrustning Eastron
- Mätutrustning ORNO
- Mätutrustning RIDGID
- Mätutrustning Westfalia
- Mätutrustning Monacor
- Mätutrustning Multimetrix
- Mätutrustning PCE
- Mätutrustning GW Instek
- Mätutrustning Logilink
- Mätutrustning SIIG
- Mätutrustning Oregon Scientific
- Mätutrustning Etymotic
- Mätutrustning Reely
- Mätutrustning Muller
- Mätutrustning TFA Dostmann
- Mätutrustning Werma
- Mätutrustning Greisinger
- Mätutrustning Beha-Amprobe
- Mätutrustning Kopp
- Mätutrustning Kogan
- Mätutrustning Kreg
- Mätutrustning Pancontrol
- Mätutrustning Peak
- Mätutrustning Uni-T
- Mätutrustning H-Tronic
- Mätutrustning Elgato
- Mätutrustning Ebro
- Mätutrustning Hikmicro
- Mätutrustning RK Technology
- Mätutrustning PeakTech
- Mätutrustning Sonel
- Mätutrustning Tru Components
- Mätutrustning Emko
- Mätutrustning Aktobis
- Mätutrustning Entes
- Mätutrustning KS Tools
- Mätutrustning Lund
- Mätutrustning Trumeter
- Mätutrustning Delta Ohm
- Mätutrustning Hanna
- Mätutrustning MGL Avionics
- Mätutrustning Adwa
- Mätutrustning Chauvin Arnoux
- Mätutrustning Megger
- Mätutrustning AREXX
- Mätutrustning Gossen Metrawatt
- Mätutrustning PCE Instruments
- Mätutrustning CEM
- Mätutrustning SHX
- Mätutrustning Hameg
- Mätutrustning TDE Instruments
- Mätutrustning Joy-it
- Mätutrustning Angler
- Mätutrustning Circutor
- Mätutrustning Wachendorff
- Mätutrustning Klein Tools
- Mätutrustning Duro Pro
- Mätutrustning Aerospace Logic
- Mätutrustning Zircon
- Mätutrustning BJZ
- Mätutrustning Johnson Level
- Mätutrustning GMW
- Mätutrustning SOEKS
- Mätutrustning Apollo Ultrasonic
- Mätutrustning Softing
- Mätutrustning Weltron
- Mätutrustning Oscium
- Mätutrustning Janitza
- Mätutrustning Sanwa
- Mätutrustning Condtrol
- Mätutrustning J.P. Instruments
- Mätutrustning MSW
- Mätutrustning Weidmüller
- Mätutrustning Qubino
- Mätutrustning Lascar Electronics
- Mätutrustning HT Instruments
- Mätutrustning P3 International
- Mätutrustning Beckmann & Egle
- Mätutrustning Seek Thermal
- Mätutrustning INFICON
- Mätutrustning Motrona
- Mätutrustning Tempo
- Mätutrustning Camille Bauer
- Mätutrustning Blebox
- Mätutrustning Seaward
- Mätutrustning HOZO Design
- Mätutrustning Corentium
- Mätutrustning GQ
- Mätutrustning Tektronix
- Mätutrustning Dostmann Electronic
- Mätutrustning Murideo
- Mätutrustning SecuTech
- Mätutrustning NetPeppers
- Mätutrustning SensoProtect
- Mätutrustning Water-i.d.
- Mätutrustning ZKETECH
- Mätutrustning LabNation
- Mätutrustning Electronics International
- Mätutrustning Cliff
- Mätutrustning ClimeMET
- Mätutrustning Fixpoint
- Mätutrustning Kübler
- Mätutrustning AkYtec
- Mätutrustning Stahlwille
- Mätutrustning MASIMO
- Mätutrustning Milesight
- Mätutrustning Enda
- Mätutrustning CSL
- Mätutrustning Ermenrich
- Mätutrustning PICO
- Mätutrustning Siglent
- Mätutrustning Noyafa
- Mätutrustning Stamos
- Mätutrustning Brookhuis
- Mätutrustning PQ Plus
- Mätutrustning Intact
- Mätutrustning Crowcon
- Mätutrustning Aeroqual
- Mätutrustning DriveTest
- Mätutrustning Helvi
Nyaste Mätutrustning Manualer
17 December 2024
17 December 2024
17 December 2024
17 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024
16 December 2024