Klein Tools CL600 Bruksanvisning

Läs nedan 📖 manual på svenska för Klein Tools CL600 (42 sidor) i kategorin Multimeter. Denna guide var användbar för 7 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/42
INSTRUCTION MANUAL
ENGLISH
FRANÇAIS pg. 29
ESPAÑOL pg. 15
600A AC Auto-Ranging
Digital Clamp Meter
Ω
NON-CONTACT
VOLTAGE TESTER
AUTO-RANGING
DATA HOLD
RANGE HOLD
AUDIBLE
CONTINUITY
DIODE TEST
True RMS
Measurement
Technology
-14° –
1000°F
(-26° –
538°C)
4007177
CL600
2
m
IP40
2
GENERAL SPECIFICATIONS
Klein Tools CL600 is an automatically ranging true root mean square
(TRMS) digital clamp-meter that measures AC current via the clamp,
and measures AC/DC voltage, resistance, continuity, and tests diodes
via test-leads.
Operating Altitude: 6562 ft. (2000m)
Relative Humidity: <80% non-condensing
Operating Temp: ° ° ° °32 to 104 F (0 to 40 C)
Storage Temp: ° ° ° °14 to 140 F (-10 to 60 C)
Accuracy: Values stated at 65° to 83°F (18° to 28°C)
Temp Coefcient: °0.1 x (Quoted Accuracy) per C above
28 C or below 18 C, corrections are required when ambient ° °
working temp is outside of Accuracy Temp range
Dimensions: 9.09" x 3.82" x 1.54" (231 x 97 x 39 mm)
Weight: 11.8 oz. (335 g) including batteries
Calibration: Accurate for one year
Standards: Conforms to: UL STD 61010-1, 61010-2-032,
61010-2-033.
Certified to: CSA STD C22.2 # 61010-1,
61010-2-032, 61010-2-033.
IEC EN 61010-1, 61010-2-032,
61010-2-033, 61326-1.
Pollution degree: 2
Accuracy: ± (% of reading + # of least significant digits)
Drop Protection: 6.6 ft. (2m)
Safety Rating: CAT IV 600V, CAT III 1000V, Class 2,
Double insulation
CAT III: Measurement category III is applicable to test and
measuring circuits connected to the distribution part of the
building’s low-voltage MAINS installation.
CAT IV: Measurement category IV is applicable to test and
measuring circuits connected at the source of the building’s
low-voltage MAINS installation.
Electromagnetic Environment: IEC EN 61326-1. This
equipment meets requirements for use in basic and controlled
electromagnetic environments like residential properties,
business premises, and light-industrial locations.
Specifications subject to change.
ENGLISH
3
ELECTRICAL SPECIFICATIONS
Function Range Resolution Accuracy (50/60 Hz)
AC Voltage
(V AC)
6.000V 1mV ±(1.5% + 5 digits)
60.00V 10mV ±(1.2% + 5 digits)
600.0V 100mV
1000V 1V ±(1.5% + 5 digits)
DC Voltage
(V DC)
600mV 0.1mV ±(1.0% + 8 digits)
6.000V 1mV
±(1.0% + 3 digits)60.00V 10mV
600.0V 100mV
1000V 1V ±(1.2% + 3 digits)
Input Impedance: 10MΩ
Frequency Range: 50 to 400Hz
Maximum Input: 1000V AC RMS or 1000V DC
AC Current
(A AC)
60.00A 10mA ±(2.0% + 8 digits)
600.0A 100mA ±(2.0% + 5 digits)
Frequency Range: 50 to 60Hz
Function Range Resolution Accuracy
Resistance
600.0Ω 0.1Ω
±(1.5% + 5 digits)
6.000KΩ 1Ω
60.00kΩ 10Ω
600.0kΩ 10
6.000MΩ 1kΩ
60.00MΩ 10kΩ ±(2.0% + 10 digits)
Maximum Input: 600V AC RMS or 600V DC
OTHER MEASUREMENT APPLICATIONS
Maximum Input: 600V AC RMS or 600V DC
Diode Test: Max. 1.5mA, open circuit voltage ~3.0V DC
Audible signal <50Ω, current <0.35mAContinuity Check:
3 samples per secondSampling Frequency:
After ~30 minutes of inactivity.Auto Power off:
Overload:
"OL" indicated on display, overload protection
1000V in Voltage setting, 600V RMS in all other settings
"-" on display indicates negative polarityPolarity:
3-5/6 digit, 6000 Count LCDDisplay:

Produktspecifikationer

Varumärke: Klein Tools
Kategori: Multimeter
Modell: CL600

Behöver du hjälp?

Om du behöver hjälp med Klein Tools CL600 ställ en fråga nedan och andra användare kommer att svara dig




Multimeter Klein Tools Manualer

Multimeter Manualer

Nyaste Multimeter Manualer