Kyoritsu KEW 5204 Bruksanvisning

Läs nedan 📖 manual på svenska för Kyoritsu KEW 5204 (2 sidor) i kategorin Ljusmätare. Denna guide var användbar för 10 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare

Sida 1/2
2. Features
Wide Range 0.1199900 lux
MAX/MIN function
Automatic Zero Adjust function
Large LCD Display with Backlight
3. Name of Parts and Position/Operation
Lens Protecting Cover
This is used to protect the
photocell from scratching and
c r e a t e c o m p l e t e d a r k
environment for the meter to
p e r f o r m d a r k c u r r e n t
calibration.
Light Sensing Probe/Photocell
LCD Display
Power button
Push this button to turn on
the meter. Please push the
button again to turn it off. The
unit will automatically turn
itself off after 30 minutes if no
key operation. To disable the
automatic power off function,
turn the meter off, push and
keep holding button, then push power button to turn on.
Backlight button
Push this button to turn on and off the LCD backlight. The backlight will
be automatically off after 30 seconds to save battery power.
HOLD button
The user may hold the present and keep it on the LCD display by
pressing the button.
Max/Min button
Push this button to set the meter working under MAX/MIN mode. By
pushing this button, the user may swap the LCD reading among current,
maximum and minimum reading. Push and hold this key for 3 seconds
to exit MAX/MIN mode.
Range selector button.
The user may use this button to select the preferred measuring or
automatically selected by the meter. The available ranges are: AUTO
200, 2000, 20000, 200000 lx
ADJ button Please refer to Measurement
1. SAFETY WARNINGS
This instruction manual contains warnings and safety rules which must be
observed by the user to ensure safe operation of the instrument and to
retain it in safe condition.
WARNING
Read through and understand instructions contained in this manual
before starting using the instrument.
Save and keep the manual handy to enable quick reference whenever
necessary.
The symbol indicated on the instrument means that the user must refer
to related parts of the manual for safe operation of the instrument. Be sure
to carefully read the instructions following each symbol in this manual.
DANGER is reserved for conditions and actions that are likely to
cause serious or fatal injury.
WARNING is reserved for conditions and actions that can cause
serious or fatal injury.
CAUTION is reserved for conditions and actions that can cause
minor injury or instrument damage.
WARNING
Do not install substitute parts or make any modification to the
instrument. Return the instrument to Kyoritsu or your distributor for
repair or re-calibration.
CAUTION
Do not expose the instrument to the direct sun, extreme temperatures
or dew fall.
This instrument isn't dust & water proofed. Keep away from dust and water.
Be sure to set the Function Selector Switch to the "OFF" position after
use. When the instrument will not be used for a long period of time,
place it in storage after removing the batteries.
Use a damp cloth and detergent for cleaning the instrument. Do not
use abrasives or solvents.
The instrument should be calibrated once a year or so for the accurate
measurement
This symbol is marked wh ere t he user must refer to the
instruct ion manual so as not to cause personal injury or
instrument damage.
This instrument satisfies the marking requirement defined in the
WEEE Directive. This symbol indicates separate collection for
electrical and electronic equipment.
Battery cabinet cover
When battery capacity segment is less
than one, the user should replace the
batter y. The batter y cabinet can be
opened with a screw driver and two AA
type batteries should be installed.
4. Specifications
MODEL KEW 5204
Light detector Silicon photo diode
Measuring Range 0.0199,900 lx
Range 199.9/1,999/19,990/199,900 lx
Resolution 0.1 lx
Accuracy ±4%rdg±5dgt23±2
Angle deviation from cosine
characteristics
10° ± 1.5%
30° ± 3%
60° ± 10%
80° ± 30%
Temperature characteristics
±5 % (at 23 reference and a range of 0 to 40)
Relative spectral sensitivity
characteristics
Deviation from spectral luminous
efficiency:9% or less
Response time Auto range:5s or less
Manual range:2s or less
Auto power off 30 min.
Dimensions 169(L)x63(W)x37(D)mm
Weight 210g approx..
Power source R6(AA)(1.5V) x 2
Operation Temperature/
Humidity
040,80%RH or lesswithout
condensation
Storage Temperature/
Humidity
-1060,70%RH or lesswithout
condensation
Continuous measuring time Approx. 80 hours
Applicable Standards JIS C 1609-1:2006
IEC61326
Accessories
Carrying case
Instruction Manual
R6(AA)(1.5V)×
5. Measurement
5-1Zero adjust
Please perform zero adjustment before measurement.
Press 0 ADJ button with the Lens Protecting Cover attached to the Light
Sensing Probe.
"CAP-" will auto-appear on the LCD display. After "CAL-" appears, the
meter enters the automatic zero adjustment. When automatic zero
adjustment is completed, "CAL-" disappears and "0.0"appears. After
confirming the "0.0" display, remove the cap to start measuring.
IfERR1appears, check the cap to make sure it is on properly.
After the measurement has been completed, press the power button
again to turn off the power, and cover the light-detecting surface with
the cap for protecting against stray light.
5-2Measurement
Place the light sensing probe parallel to the measuring object and
measure it. At this time, please be careful that your own shadow does
not hit the sensing probe.
The light sensing probe can be fixed on the meter parallel or
perpendicular to the LCD Display. Or it may be detached from the unit to
fit the measuring requirement.
05-18 92-2349
INSTRUCTIONMANUAL
DIGITALLIGHTMETER
LIGHTMETERSERIES
KEW5204
ADEQUATE LIGHT LEVELS FOR YOUR WORKING OR AT YOUR WORK AREAS.
LUXES (lx) 3,000 2,000 1,500 1,000 750 500 300 200 150 100 75 50 30 20 15 10 7
OFFICE
Entrance hall (day-time)
Director room
Inquiry office, Dining
room
Night-duty room Stair
Indoor emergency
staircase
Council room
Electronic computer room
Reception room
Guard station
Library, Tearoom
Dressing room
Toilet, lavatory Warehouse, Lift, Passage
FACTORY
Extra fine visual work Design room
Drawing room
Stair
Indoor emergency
staircase
Control room,
Electric room
Air conditioning machine
room, lavatory, Toilet
Entrance
Passage Path
Warehouse
SCHOOL
Drawing room
Classroom, Faculty room,
Dining room, Gymnasium
Night-duty room Stair
Clothing classroom,
Electronic computer room
Experimental laboratory
Reading room
Healthcare room
Auditorium, Assembly
room
Locker room
lavatory, Toilet
Passage
HOSPITAL
Operating room
Emergency room
Consultation room
Nurse station
Pharmacist office
Pharmacist's oce
General examination room
Physiological examination
room, Radioisotope room
Funeral chapel
Nursery room
Waiting room
Visiting room
Passage for outpatients
Changing room, lavatory
Hospital charts room
Toilet
Ward Emergency staircase
X-ray room
Physiotherapy room,
Exercise machine room
Night-duty room
Endoscopy room, X-ray
fluoroscopy room
Ophthalmic dark room
STORE
Most important
part of display
Lift lobby, Escalator Reception room
lavatory, Toilet Passage, Resting room
Important part of display,
Register, Packaging stand
Negotiation room Stair
RESTAURANT
Sample case Register Stair
Cookroom
Dining table
Counter
Waiting room
Guest room
lavatory, Toilet
Porch, Passage
THEATRE
CONCERT HALL
Ticket ofce
Spectator seats, Lobby
Electric room
Mechanical room
lavatory, Toilet
Entrance
Resting room
Projection room
Passage Monitoring room
(during performance)
Projection room
(during performance)
Stall, Green room
Monitoring room
Stair
Theatre basement work
room
INN, HOTEL
Front desk
Counter, Oce
Carriage porch
Dining room Stair Important parts of garden
Cuisine
Guest room desk Banqueting hall, Salle
Lobby, lavatory, Toilet
Game room, Guest room,
Entrance, Passage,
Bathroom
Undressing room
BEAUTY SALON
BARBAR SHOP
Hair dressing, Hair dyeing
Hair set, Make-up
Hair cut, Shaving
Dressing
Shampooing, Register
Stair
Toilet inside the shop Passage
(JIS Z9110-2010)
DISTRIBUTOR
Kyoritsu reserves the rights to change specifications or designs described
in this manual without notice and without obligations.
REF. LEVEL

Produktspecifikationer

Varumärke: Kyoritsu
Kategori: Ljusmätare
Modell: KEW 5204
Färg på produkten: Zwart
Vikt: 4083 g
Bredd: 483 mm
Djup: 229 mm
Höjd: 45 mm
Snäll: Stroomstrip
Kraftkälla: AC
Nuvarande: 20 A
På / Av knapp: Ja
Inbyggd fläkt: Nee
Med lås: Nee
Ursprungsland: Verenigde Staten
Antal per paket: 1 stuk(s)
Inspänning: 120 V
Rackkapacitet: 1U
AC-ingångsfrekvens: 60 Hz
Strömförbrukning (typiskt): 2400 W
Antal AC-utgångar: 9 AC-uitgang(en)
Hjulhjul: Nee

Behöver du hjälp?

Om du behöver hjälp med Kyoritsu KEW 5204 ställ en fråga nedan och andra användare kommer att svara dig