IBM System x3500 M4 Type 7383
Installation and Users Guide

IBM System x3500 M4 Type 7383
Installation and Users Guide

Important:
Each caution and danger statement in this documentation is labeled
with a number. This number is used to cross reference an English
language caution or danger statement with translated versions of the
caution or danger statement in the document.Safety Information
For example, if a caution statement is labeled "Statement 1,"
translations for that caution statement are in the Safety Information
document under "Statement 1."
Be sure to read all caution and danger statements in this document
before you perform the procedures. Read any additional safety
information that comes with the server or optional device before you
install the device.
viii IBM System x3500 M4 Type 7383: Installation and User’s Guide
Attention: Use No. 26 AWG or larger UL-listed or CSA certified
telecommunication line cord.
Statement 1:
DANGER
Electrical current from power, telephone, and communication cables is
hazardous.
To avoid a shock hazard:
vDo not connect or disconnect any cables or perform installation,
maintenance, or reconfiguration of this product during an electrical
storm.
vConnect all power cords to a properly wired and grounded electrical
outlet.
vConnect to properly wired outlets any equipment that will be attached to
this product.
vWhen possible, use one hand only to connect or disconnect signal
cables.
vNever turn on any equipment when there is evidence of fire, water, or
structural damage.
vDisconnect the attached power cords, telecommunications systems,
networks, and modems before you open the device covers, unless
instructed otherwise in the installation and configuration procedures.
vConnect and disconnect cables as described in the following table when
installing, moving, or opening covers on this product or attached
devices.
To Connect: To Disconnect:
1. Turn everything OFF.
2. First, attach all cables to devices.
3. Attach signal cables to connectors.
4. Attach power cords to outlet.
5. Turn device ON.
1. Turn everything OFF.
2. First, remove power cords from outlet.
3. Remove signal cables from connectors.
4. Remove all cables from devices.
Safety ix
Statement 2:
CAUTION:
When replacing the lithium battery, use only IBM Part Number 33F8354 or an
equivalent type battery recommended by the manufacturer. If your system has
a module containing a lithium battery, replace it only with the same module
type made by the same manufacturer. The battery contains lithium and can
explode if not properly used, handled, or disposed of.
Do not:
vThrow or immerse into water
vHeat to more than 100°C (212°F)
vRepair or disassemble
Dispose of the battery as required by local ordinances or regulations.
xIBM System x3500 M4 Type 7383: Installation and User’s Guide
Statement 3:
CAUTION:
When laser products (such as CD-ROMs, DVD drives, fiber optic devices, or
transmitters) are installed, note the following:
vDo not remove the covers. Removing the covers of the laser product could
result in exposure to hazardous laser radiation. There are no serviceable
parts inside the device.
vUse of controls or adjustments or performance of procedures other than
those specified herein might result in hazardous radiation exposure.
DANGER
Some laser products contain an embedded Class 3A or Class 3B laser
diode. Note the following.
Laser radiation when open. Do not stare into the beam, do not view directly
with optical instruments, and avoid direct exposure to the beam.
Class 1 Laser Product
Laser Klasse 1
Laser Klass 1
Luokan 1 Laserlaite
Appareil A Laser de Classe 1
`
Safety xi
Statement 4:
≥ ≥ ≥18 kg (39.7 lb.) 32 kg (70.5 lb.) 55 kg (121.2 lb.)
CAUTION:
Use safe practices when lifting.
Statement 5:
CAUTION:
The power control button on the device and the power switch on the power
supply do not turn off the electrical current supplied to the device. The device
also might have more than one power cord. To remove all electrical current
from the device, ensure that all power cords are disconnected from the power
source.
1
2
Statement 6:
CAUTION:
Do not place any objects on top of a rack-mounted device unless that
rack-mounted device is intended for use as a shelf.
Statement 8:
xii IBM System x3500 M4 Type 7383: Installation and User’s Guide
CAUTION:
Never remove the cover on a power supply or any part that has the following
label attached.
Hazardous voltage, current, and energy levels are present inside any
component that has this label attached. There are no serviceable parts inside
these components. If you suspect a problem with one of these parts, contact
a service technician.
Statement 11:
CAUTION:
The following label indicates sharp edges, corners, or joints nearby.
Statement 12:
CAUTION:
The following label indicates a hot surface nearby.
Statement 13:
DANGER
Overloading a branch circuit is potentially a fire hazard and a shock hazard
under certain conditions. To avoid these hazards, ensure that your system
electrical requirements do not exceed branch circuit protection
requirements. Refer to the information that is provided with your device for
electrical specifications.
Safety xiii
CAUTION:
Hazardous energy present. Voltages with hazardous energy might cause
heating when shorted with metal, which might result in splattered metall,
burns, or both.
Attention: This server is suitable for use on an IT power distribution system
whose maximum phase-to-phase voltage is 240 V under any distribution fault
condition.
Safety xv
xvi IBM System x3500 M4 Type 7383: Installation and User’s Guide
Note: The illustrations in this document might differ slightly from your model.
Record information about the server in the following table.
Product name IBM System x3500 M4 server
Machine type 7383
Model number _____________________________________________
Serial number _____________________________________________
The model number and serial number are on the ID label on the front of the server,
as shown in the following illustration.
Note: The illustrations in this document might differ slightly from your hardware.
Model type/serial number
You can download an IBM CD to help youServerGuide Setup and Installation
configure the hardware, install device drivers, and install the operating system.
For a list of supported optional devices for the server, see http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
See the document on the IBMRack Installation Instructions System x
Documentation CD for complete rack installation and removal instructions.
The IBM System x Documentation CD
The IBM CD contains documentation for the server inSystem x Documentation
Portable Document Format (PDF) and includes the IBM Documentation Browser to
help you find information quickly.
2IBM System x3500 M4 Type 7383: Installation and User’s Guide
Hardware and software requirements
The IBM CD requires the following minimum hardwareSystem x Documentation
and software:
vMicrosoft Windows XP, Windows 2000, or Red Hat Linux
v100 MHz microprocessor
v32 MB of RAM
vAdobe Acrobat Reader 3.0 (or later) or xpdf, which comes with Linux operating
systems
Using the Documentation Browser
Use the Documentation Browser to browse the contents of the CD, read brief
descriptions of the documents, and view documents, using Adobe Acrobat Reader
or xpdf. The Documentation Browser automatically detects the regional settings in
use in your server and displays the documents in the language for that region (if
available). If a document is not available in the language for that region, the
English-language version is displayed.
Use one of the following procedures to start the Documentation Browser:
vIf Autostart is enabled, insert the CD into the CD or DVD drive. The
Documentation Browser starts automatically.
vIf Autostart is disabled or is not enabled for all users, use one of the following
procedures:
If you are using a Windows operating system, insert the CD into the CD or
DVD drive and click Start -> Run. In the Open field, type
e:\win32.bat
where is the drive letter of the CD or DVD drive, and click .eOK
If you are using Red Hat Linux, insert the CD into the CD or DVD drive; then,
run the following command from the /mnt/cdrom directory:
sh runlinux.sh
Select the server from the menu. TheProduct Available Topics list displays all the
documents for the server. Some documents might be in folders. A plus sign (+)
indicates each folder or document that has additional documents under it. Click the
plus sign to display the additional documents.
When you select a document, a description of the document is displayed under
Topic Description. To select more than one document, press and hold the Ctrl key
while you select the documents. Click to view the selected document orView Book
documents in Acrobat Reader or xpdf. If you selected more than one document, all
the selected documents are opened in Acrobat Reader or xpdf.
To search all the documents, type a word or word string in the field andSearch
click . The documents in which the word or word string appears are listed inSearch
order of the most occurrences. Click a document to view it, and press Crtl+F to use
the Acrobat search function, or press Alt+F to use the xpdf search function within
the document.
Click for detailed information about using the Documentation Browser.Help
Chapter 1. The System x3500 M4 server 3
Related documentation
This contains general information about the serverInstallation and User’s Guide
including how to set up and cabling the server, how to install supported optional
devices, and how to configure the server. The following documentation also comes
with the server:
vEnvironmental Notices and User Guide
This document is in PDF on the IBM CD. It containsSystem x Documentation
translated environmental notices.
vIBM License Agreement for Machine Code
This document is in PDF. It provides translated versions of the IBM License
Agreement for Machine Code for your product.
vIBM Warranty Information
This printed document contains the warranty terms and a pointer to the IBM
Statement of Limited Warranty on the IBM website.
vLicenses and Attributions Documents
This document is in PDF. It provides the open-source notices.
vProblem Determination and Service Guide
This document is in PDF on the IBM CD. It containsSystem x Documentation
information to help you solve problems yourself, and it contains information for
service technicians.
vSafety Information
This document is in PDF on the IBM CD. It containsSystem x Documentation
translated caution and danger statements. Each caution and danger statement
that appears in the documentation has a number that you can use to locate the
corresponding statement in your language in the document.Safety Information
Depending on the server model, additional documentation might be included on the
IBM CD.System x Documentation
The System x and BladeCenter Tools Center is an online information center that
contains information about tools for updating, managing, and deploying firmware,
device drivers, and operating systems. The System x and BladeCenter Tools Center
is at http://publib.boulder.ibm.com/infocenter/toolsctr/v1r0/index.jsp.
The server might have features that are not described in the documentation that
you received with the server. The documentation might be updated occasionally to
include information about those features, or technical updates might be available to
provide additional information that is not included in the server documentation.
These updates are available from the IBM website. To check for updates, go to
http://www.ibm.com/supportportal/.
Notices and statements in this document
The caution and danger statements in this document are also in the multilingual
Safety Information System x Documentationdocument, which is on the IBM CD.
Each statement is numbered for reference to the corresponding statement in your
language in the document.Safety Information
The following notices and statements are used in this document:
vNote: These notices provide important tips, guidance, or advice.
4IBM System x3500 M4 Type 7383: Installation and User’s Guide
vImportant: These notices provide information or advice that might help you avoid
inconvenient or problem situations.
vAttention: These notices indicate potential damage to programs, devices, or
data. An attention notice is placed just before the instruction or situation in which
damage might occur.
vCaution: These statements indicate situations that can be potentially hazardous
to you. A caution statement is placed just before the description of a potentially
hazardous procedure step or situation.
vDanger: These statements indicate situations that can be potentially lethal or
extremely hazardous to you. A danger statement is placed just before the
description of a potentially lethal or extremely hazardous procedure step or
situation.
Chapter 1. The System x3500 M4 server 5
Features and specifications
The following information is a summary of the features and specifications of the
server. Depending on the model, some features might not be available, or some
specifications might not apply.
Table 1. Features and specifications
Microprocessor:
vSupport up to two Intel Xeon E5-2600
series multi-core microprocessors with
integrated memory controller and Quick
Path Interconnect (QPI) architecture
vUp to 2.5M Level-3 cache/core
vTwo QuickPath Interconnect (QPI) links
speed up to 8.0 GT per second
Note:
vUse the Setup utility program to
determine the type and speed of the
microprocessors.
vFor a list of supported microprocessors,
see http://www.ibm.com/servers/eserver/
serverproven/compat/us/.
Memory:
vSlot: 12 DIMM connectors (24 DIMM
connectors when the microprocessor 2
expansion board is installed)
vMinimum: 2 GB
vMaximum: 768 GB
32 GB using unbuffered DIMMs
(UDIMMs)
384 GB using registered DIMMs
(RDIMMs)
768 GB using load reduction DIMMs
(LRDIMMs)
vType:
PC3-8500 (DDR3-1066), PC3-10600
(DDR3-1333), or PC3-12800
(DDR3-1600)
Single-rank, dual-rank, or quad-rank
Registered DIMM (RDIMM),
unbuffered DIMM (UDIMM), or load
reduced DIMM (LRDIMM)
vSupports (depending on the model):
2 GB unbuffered DIMM (UDIMM)
2 GB, 4 GB, 8 GB, and 16 GB
registered DIMMs (RDIMMs)
32 GB load reduction DIMM
(LRDIMM)
Drives:
vSATA:
– DVD-ROM
– Multi-burner
Note: Maximum of two devices can be
installed
vDiskette: External USB hard disk drive
vSupported hard disk drives:
Serial Attached SCSI (SAS)
Serial ATA (SATA)
Expansion bays (depending on the
model):
vUp to thirty-two 2.5-inch HDD bays
vUp to eight 3.5-inch HDD bays
vUp to two half-high 5.25-inch bays
Note: Full-high devices such as an
optional tape drive will occupy two
half-high 5.25-inch bays.
PCI and PCI-X expansion slots:
vSix PCI expansion slots on the system
board:
Slot 1: PCI Express 2.0 x8 (support
optional PCI-X interposer card)
Slot 2: PCI Express 3.0 x8
Slot 3: PCI Express 3.0 x8
Slot 4: PCI Express 3.0 x8
Slot 5: PCI Express 3.0 x16
(support 225W GPU)
Slot 6: PCI Express 3.0 x8
vTwo PCI expansion slots on the
microprocessor 2 expansion board:
Slot 7: PCI Express 3.0 x16
(support 225W GPU)
Slot 8: PCI Express 3.0 x16
vPCI-X interposer card (optional):
One PCI-X 64-bit/133 MHz
Video controller (integrated into
IMM2):
vMatrox G200eR2
Note: The maximum video resolution
is 1600 x 1200 at 75 Hz.
SVGA compatible video controller
DDR3 528 MHz SDRAM video
memory controller
Avocent Digital Video Compression
16 MB of video memory (not
expandable)
Power supply:
vUp to two hot-swap power supplies for
redundancy support
750-watt ac
1. Support up to sixteen 2.5-inch
HDDs.
2. GPU not supported.
900-watt ac
1. One GPU and one power supply
installed: support up to 8 HDDs.
2. One GPU and two power supplies
installed:
- Support up to 8 HDDs in
redundant mode.
- More than 8 HDDs installed, the
server runs in non-redundant
mode.
3. Two GPUs and two power
supplies installed: the server runs
in non-redundant mode.
Note: Power supplies in the server must be
with the same power rating or wattage.
Simple-swap fans:
vTwo (one microprocessor installed)
vThree (two microprocessors installed)
vThree additional fans (for optional
redundant cooling)
Size:
vTower
Height: 440 mm (17.3 in.)
Depth: 750 mm (29.5 in.)
Width: 218 mm (8.6 in.)
Weight: approximately 39.8 kg (87.7
lb) when fully configured or 25.0 kg
(55.1 lb) minimum
vRack
5 U
Height: 218 mm (8.6 in.)
Depth: 702 mm (27.6 in.)
Width: 424 mm (16.7 in.)
Weight: approximately 39.3 kg (86.6
lb) when fully configured or 24.5 kg
(54.0 lb) minimum
Racks are marked in vertical increments of
4.45 cm (1.75 inches). Each increment is
referred to as a unit, or “U.” A 1-U-high
device is 4.45 cm (1.75 inches) tall.
6IBM System x3500 M4 Type 7383: Installation and User’s Guide
Table 1. Features and specifications (continued)
Integrated functions:
vIntegrated Management Module II
(IMM2), which consolidates multiple
management functions in a single chip.
vIntel I350AM4 Quad Port Gigabit
Ethernet controller with Wake on LAN
support
vSerial over LAN (SOL) and serial
redirection over Telnet or Secure Shell
(SSH)
vOne systems-management 1 Gb
Ethernet port for connection to a
dedicated systems-management
network. This system management
connector is dedicated to the IMM2
functions.
vLight path diagnostics
vSix Universal Serial Bus (USB) ports
standard
Two on front of server
Four on rear of server
vOne internal USB port for optional USB
flash device with embedded hypervisor
vOne internal USB tape connector
vOne serial connector
RAID controllers (depending on the
model):
vA ServeRAID M1115 SAS/SATA adapter
that provides RAID 0, 1, and 10 with
optional FoD RAID 5/50 and SED (Self
Encrypting Drive) upgrade.
vA ServeRAID M5110 SAS/SATA adapter
that provides RAID 0, 1, and 10.
Optional upgrade:
RAID 5/50 (512 MB Cache) with
optional FoD RAID 6/60 and SED
upgrade
RAID 5/50 (512 MB Flash) with
optional FoD RAID 6/60 and SED
upgrade
RAID 5/50 (1 GB Flash) with optional
FoD RAID 6/60 and SED upgrade
RAID 5/50 and SED (Zero Cache)
Acoustical noise emissions:
vSound power, idling: 6.0 bels
vSound power, operating: 6.0 bels
Environment:
vAir temperature:
Server on: 10°C to 35°C (50.0°F to
95.0°F); altitude: 0 to 914.4 m
(3000 ft)
Server on: 10°C to 32°C (50.0°F to
89.6°F); altitude: 914.4 m (3000 ft)
to 2133.6 m (7000 ft)
Server off (with standby power):
10°C to 43°C (50.0°F to 109.4°F);
maximum altitude: 2133.6 m (7000
ft)
Shipment: -40°C to 60°C (-40°F to
140°F)
vHumidity:
Server on: 8% to 80%; maximum
dew point 21°C; maximum rate of
change: 5°C/hour
Server off (with standby power): 8%
to 80%; maximum dew point: 27°C
vParticulate contamination:
Attention: Airborne particulates and
reactive gases acting alone or in
combination with other environmental
factors such as humidity or
temperature might pose a risk to the
server. For information about the limits
for particulates and gases, see
“Particulate contamination” on page
137.
Heat output:
Approximate heat output:
vMinimum configuration: 2013 Btu per
hour (590 watts)
vMaximum configuration: 3610 Btu per
hour (1058 watts)
Electrical input:
vSine-wave input (50 - 60 Hz) required
vInput voltage low range:
Minimum: 100 V ac
Maximum: 127 V ac
vInput voltage high range:
Minimum: 200 V ac
Maximum: 240 V ac
vInput kilovolt-amperes (kVA),
approximately:
Minimum: 0.60 kVA
Maximum: 1.10 kVA
Notes:
1. Power consumption and heat output
vary depending on the number and type
of optional features installed and the
power-management optional features in
use.
2. The noise emission level stated is the
declared (upper limit) sound power
level, in bels, for a random sample of
machines. All measurements are made
in accordance with ISO 7779 and
reported in conformance with ISO 9296.
Chapter 1. The System x3500 M4 server 7
What your server offers
The server uses the following features and technologies:
vIntegrated Management Module II
The integrated management module II (IMM2) is the second generation of the
IMM. The IMM2 is the common management controller for IBM System x
hardware. The IMM2 consolidates multiple management functions in a single chip
on the server system board.
Some of the features that are unique to the IMM2 are enhanced performance,
expanded compatibility with blade servers, higher-resolution remote video,
expanded security options, and Feature on Demand enablement for hardware
and firmware options.
For additional information, see “Using the Integrated Management Module II” on
page 124.
vUEFI-compliant server firmware
IBM System x Server Firmware (server firmware) offers several features,
including Unified Extensible Firmware Interface (UEFI) 2.1 compliance; Active
Energy Manager technology; enhanced reliability, availability, and serviceability
(RAS) capabilities; and basic input/output system (BIOS) compatibility support.
UEFI replaces the BIOS and defines a standard interface between the operating
system, platform firmware, and external devices. UEFI-compliant System x
servers are capable of booting UEFI-compliant operating systems, BIOS-based
operating systems, and BIOS-based adapters as well as UEFI-compliant
adapters.
Note: The server does not support DOS (Disk Operating System).
vIBM Dynamic System Analysis Preboot diagnostics programs
The Dynamic System Analysis (DSA) Preboot diagnostics programs are stored
on the integrated USB memory. It collects and analyzes system information to aid
in diagnosing server problems. The diagnostic programs collect the following
information about the server:
System configuration
Network interfaces and settings
Installed hardware
Light path diagnostics status
Service processor status and configuration
Vital product data, firmware, and UEFI (formerly BIOS) configuration
Hard disk drive health
RAID controller configuration
Event logs for ServeRAID controllers and service processors
The diagnostic programs create a merged log that includes events from all
collected logs. The information is collected into a file that you can send to IBM
service and support. Additionally, you can view the information locally through a
generated text report file. You can also copy the log to a removable media and
view the log from a web browser.
For additional information about DSA Preboot diagnostics, see the Problem
Determination and Service Guide System x Documentationon the IBM CD
vMulti-core processing
The server supports up to two Intel XeonE5-2600 series multi-core
microprocessors. The server comes with only one microprocessor installed.
8IBM System x3500 M4 Type 7383: Installation and User’s Guide
vIBM Systems Director CD
IBM Systems Director is a workgroup-hardware-management tool that you can
use to centrally manage System x and xSeries servers. For more information,
see the IBM Systems Director documentation on the CDIBM Systems Director
and “IBM Systems Director” on page 12.
vIBM X-Architecture technology
IBM X-Architecture technology combines proven, innovative IBM designs to make
your Intel-processor-based server powerful, scalable, and reliable. For more
information, see http://www.ibm.com/servers/eserver/xseries/xarchitecture/
enterprise/index.html.
ActiveMemory
The Active Memory feature improves the reliability of memory through memory
mirrored channel. Memory mirrored channel mode replicates and stores data
on two pairs of DIMMs within two channels simultaneously. If a failure occurs,
the memory controller switches from the primary pair of memory DIMMs to the
backup pair of DIMMs. For more information about installing DIMMs for
memory mirrored channel, see “Installing a memory module” on page 77.
Large system-memory capacity
The memory bus supports up to 384 GB of system memory when registered
DIMMs are installed. The server supports up to 64 GB if unbuffered DIMMs
are installed. The memory controller supports error correcting code (ECC) for
up to 24 industry-standard PC3-8500 (DDR3-1066), PC3-10600 (DDR3-1333),
or PC3-12800 (DDR3-1600), DDR3 (third-generation double-data-rate),
synchronous dynamic random access memory (SDRAM) dual inline memory
modules (DIMMs).
vIBM CDServerGuide Setup and Installation
The CD, which you can download from theServerGuide Setup and Installation
web, provides programs to help you set up the server and install a Windows
operating system. The ServerGuide program detects installed optional hardware
devices and provides the correct configuration programs and device drivers. For
more information about the CD, see “UsingServerGuide Setup and Installation
the ServerGuide Setup and Installation CD” on page 116.
vIntegrated network support
The server comes with an integrated dual-port Intel Gigabit Ethernet controller,
which supports connection to a 10 Mbps, 100 Mbps, or 1000 Mbps network. For
more information, see “Configuring the Gigabit Ethernet controller” on page 128.
vIntegrated Trusted Platform Module (TPM)
This integrated security chip performs cryptographic functions and stores private
and public secure keys. It provides the hardware support for the Trusted
Computing Group (TCG) specification. You can download the software to support
the TCG specification, when the software is available. See http://www.ibm.com/
servers/eserver/xseries/scalable_family.html for details about the TPM
implementation. You can enable TPM support through the Setup utility under the
System Security menu option.
vLarge data-storage capacity and hot-swap capability
The hot-swap server models support a maximum of thirty-two 2.5-inch or eight
3.5-inch hot-swap Serial Attached SCSI (SAS) hard disk drives or hot-swap
Serial ATA (SATA) hard disk drives. The simple-swap server models support a
maximum of eight 3.5-inch simple-swap SATA hard disk drives.
With the hot-swap feature, you can add, remove, or replace hard disk drives
without turning off the server.
vLight path diagnostics
Chapter 1. The System x3500 M4 server 9
Light path diagnostics provides LEDs to help you diagnose problems. For more
information about the light path diagnostics, see “Light path diagnostics panel” on
page 15 and the on the IBMProblem Determination and Service Guide System x
Documentation CD.
vPCI adapter capabilities
The server has six PCI interface slots. Slot 1 can support PCI Express or PCI-X
adapters through an optional PCI-X interposer card. See “Installing an adapter”
on page 85 for detailed information.
vActive Energy Manager
The IBM Active Energy Manager solution is an IBM Systems Director plug-in that
measures and reports server power consumption as it occurs. This enables you
to monitor power consumption in correlation to specific software application
programs and hardware configurations. You can obtain the measurement values
through the systems-management interface and view them, using IBM Systems
Director. For more information, including the required levels of IBM Systems
Director and Active Energy Manager, see the IBM Systems Director
documentation on the IBM , or see http://www.ibm.com/Systems Director CD
servers/systems/management/director/resources/.
vRedundant connection
The addition of the optional Ethernet daughter card provides failover capability to
a redundant Ethernet connection with the applicable application installed. If a
problem occurs with the primary Ethernet connection and the optional Ethernet
daughter card is installed on the server, all Ethernet traffic that is associated with
the primary connection is automatically switched to the optional redundant
Ethernet daughter card connection. If the applicable device drivers are installed,
this switching occurs without data loss and without user intervention.
vRedundant cooling and optional power capabilities
The server supports a maximum of two 750-watt or 900-watt hot-swap power
supplies and six simple-swap fans, which provide redundancy and hot-swap
capability for a typical configuration. The redundant cooling by the fans in the
server enables continued operation if one of the fans fails. The server comes
with one 750-watt or 900-watt hot-swap power supply and two fans.
You must install fan 2 when you install the second microprocessor in the server.
You can order the optional fan 4, 5, and 6 for cooling redundancy. You can order
the second optional power supply for power redundancy.
Notes:
1. You cannot mix 750-watt and 900-watt power supplies in the server.
2. The server is not running in power redundant mode with two 225W GPUs
installed, two 900-watt power supplies are required.
vServeRAID support
The ServeRAID adapter provides hardware redundant array of independent disks
(RAID) support to create configurations. The standard RAID adapter provides
RAID levels 0, 1, and 10. An optional RAID adapter is available for purchase.
vSystems-management capabilities
The server comes with an integrated management module II (IMM2). When the
IMM2 is used with the systems-management software that comes with the server,
you can manage the functions of the server locally and remotely. The IMM2 also
provides system monitoring, event recording, and network alert capability. The
system-management connector on the rear of the server is dedicated to the
IMM2. The dedicated system-management connector provides additional security
by physically separating the management network traffic from the production
10 IBM System x3500 M4 Type 7383: Installation and Users Guide
network. You can use the Setup utility to configure the server to use a dedicated
systems-management network or a shared network.
Reliability, availability, and serviceability
Three important computer design features are reliability, availability, and
serviceability (RAS). The RAS features help to ensure the integrity of the data that
is stored in the server, the availability of the server when you need it, and the ease
with which you can diagnose and correct problems.
Your server has the following RAS features:
v3-year parts and 3-year labor limited warranty for machine type 7383
vAutomatic error retry and recovery
vAutomatic restart on nonmaskable interrupt (NMI)
vAutomatic restart after a power failure
vBackup basic input/output system switching under the control of the Integrated
Management Module II (IMM2)
vBuilt-in monitoring for fan, power, temperature, voltage, and power-supply
redundancy
vChipkill memory protection
vDiagnostic support for ServeRAID and Ethernet adapters
vError correcting code (ECC) L2 cache and system memory
vSimple-swap cooling fans with speed-sensing capability
vHot-swap hard disk drives
vInformation and light path diagnostics LED panels
vIntegrated Management Module II (IMM2)
vMenu-driven setup, system configuration, and redundant array of independent
disks (RAID) configuration programs
vMicroprocessor built-in self-test (BIST), internal error signal monitoring,
configuration checking, and microprocessor and voltage regulator module failure
identification through light path diagnostics
vMemory mirrored channel support (memory mirrored channel are mutually
exclusive of each other)
vParity checking on the small computer system interface (SCSI) bus and PCI
buses
vPower management: Compliance with Advanced Configuration and Power
Interface (ACPI)
vPower-on self-test (POST)
vPredictive Failure Analysis (PFA) alerts on memory, SAS/SATA hard disk drives,
fans, and power supplies
vRedundant Ethernet capabilities with failover support
vRedundant hot-swap power supplies and redundant simple-swap fans
vRedundant Network Interface Card (NIC) support
vRemind button to temporarily turn on the system-error LED
vRemote system problem-determination support
vROM-based diagnostics
vROM checksums
vSerial Presence Detection (SPD) on memory, VPD, power supply, and hard disk
drives backplane
vDIMM isolation of excessive correctable error or multi-bit error by the Unified
Extensible Firmware Interface (UEFI)
vStandby voltage for system-management features and monitoring
vStartup (boot) from LAN through remote initial program load (RIPL) or dynamic
host configuration protocol/boot protocol (DHCP/BOOTP)
vSystem auto-configuring from the configuration menu
vSystem-error logging (POST and IMM2)
Chapter 1. The System x3500 M4 server 11
vSystems-management monitoring through the Inter-Integrated Circuit (IC)
protocol bus
vUpgradeable POST, Unified Extensible Firmware Interface (UEFI), diagnostics,
IMM2 firmware, and read-only memory (ROM) resident code, locally or over the
LAN
vVital product data (VPD) on microprocessors, system board, power supplies, and
SAS/SATA (hot-swap hard disk drive) backplane
vWake on LAN capability
IBM Systems Director
IBM Systems Director is a platform-management foundation that streamlines the
way you manage physical and virtual systems supports multiple operating systems
and virtualization technologies in IBM and non-IBM x86 platforms.
Through a single user interface, IBM Systems Director provides consistent views for
viewing managed systems, determining how these systems relate to one other, and
identifying their statuses, helping to correlate technical resources with business
needs. A set of common tasks that are included with IBM Systems Director provides
many of the core capabilities that are required for basic management, which means
instant out-of-the-box business value. The common tasks include the following:
vDiscovery
vInventory
vConfiguration
vSystem health
vMonitoring
vUpdates
vEvent notification
vAutomation for managed systems
The IBM Systems Director web and command-line interfaces provide a consistent
interface that is focused on driving these common tasks and capabilities:
vDiscovering, navigating, and visualizing systems on the network with the detailed
inventory and relationships to the other network resources
vNotifying users of problems that occur on systems and the ability to isolate the
sources of the problems
vNotifying users when systems need updates and distributing and installing
updates on a schedule
vAnalyzing real-time data for systems and setting critical thresholds that notify the
administrator of emerging problems
vConfiguring settings of a single system and creating a configuration plan that can
apply those settings to multiple systems
vUpdating installed plug-ins to add new features and functions to the base
capabilities
vManaging the life cycles of virtual resources
For more information about IBM Systems Director, see the documentation on the
IBM Systems Director CD that comes with the server and the IBM xSeries Systems
Management web page at http://www.ibm.com/systems/software/director/, which
presents an overview of IBM Systems Management and IBM Systems Director.
12 IBM System x3500 M4 Type 7383: Installation and User’s Guide
vDVD drive activity LED: When this LED is lit, it indicates that the DVD drive is
in use.
vDVD eject button: Press this button to release a DVD or CD from the DVD
drive.
vLight path diagnostics panel: Light path diagnostics is a system of LEDs on
various external and internal components of the server. When an error occurs,
LEDs are lit throughout the server. By viewing the LEDs in a particular order, you
can often identify the source of the error. See “Light path diagnostics panel” on
page 15 for more information about the light path diagnostics.
vOperator information panel: This panel contains controls and LEDs that provide
information about the status of the server. For information about the controls and
LEDs on the operator information panel, see “Operator information panel.”
vRemind button: This button places the system-error LED/check log LED on the
operator information panel into Remind mode. In Remind mode, the system-error
LED flashes once every 2 seconds until the problem is corrected, the server is
restarted, or a new problem occurs.
By placing the system-error LED indicator in Remind mode, you acknowledge
that you are aware of the last failure but will not take immediate action to correct
the problem. The remind function is controlled by the IMM2.
vReset button: Press this button to reset the server and run the power-on
self-test (POST). You might have to use a pen or the end of a straightened paper
clip to press the button. The Reset button is in the lower-right corner of the light
path diagnostics panel.
vUSB connectors: Connect a USB device, such as a USB mouse or keyboard to
any of these connectors.
Operator information panel
The following illustration shows the controls and LEDs on the operator information
panel.
System error LED
Check log LED
System locator LED
Power-on LED Ethernet activity LED
vPower-on LED: When this LED is lit and not flashing, it indicates that the server
is turned on. The states of the power-on LED are as follows:
Off: Power is not present or the power supply, or the LED itself has failed.
Flashing rapidly (4 times per second): The server is turned off and is not
ready to be turned on. The power-control button is disabled. This will last
approximately 5 to 10 seconds.
Flashing slowly (once per second): The server is turned off and is ready to
be turned on. You can press the power-control button to turn on the server.
Lit: The server is turned on.
vEthernet activity LEDs: When any of these LEDs is flashing, they indicate that
the server is transmitting to or receiving signals from the Ethernet LAN that is
connected to the Ethernet port that corresponds to that LED.
vSystem-locator LED: Use this blue LED to visually locate the server among
other servers. You can use IBM Systems Director to light this LED remotely. This
LED is controlled by the IMM2. When you light the system-locator LED, the LED
will blink and it will continue to blink until you turn it off.
14 IBM System x3500 M4 Type 7383: Installation and Users Guide
vCheck log LED: When this amber LED is lit, it indicates that a system error has
occurred. Check the error log for additional information. See the Problem
Determination and Service Guide System x Documentationon the CD for more
information about error logs.
vSystem-error LED: When this amber LED is lit, it indicates that a system error
has occurred. An LED on the light path diagnostics panel is lit to help isolate the
error. This LED is controlled by the IMM2.
The following table describes the LEDs on the operator information panel and
suggested actions to correct the detected problems.
LED Description Action
System locator (blue) Use this LED to visually locate the server
among other servers. You can use IBM
Systems Director or IMM2 to light this LED
remotely.
Check log (amber) An error has occurred and cannot be
isolated without performing certain
procedures.
1. Check the IMM2 system event log and
the system-error log for information
about the error.
2. Save the log if necessary and clear the
log afterwards.
System-error (amber) An error has occurred. 1. Check the light path diagnostics LEDs
and follow the instructions.
2. Check the IMM2 system event log and
the system-error log for information
about the error.
3. Save the log if necessary and clear the
log afterwards.
Light path diagnostics panel
The following illustration shows the front LEDs on the light path diagnostics panel.
The light path diagnostic panel can be seen from the front bezel.
Note: The light path diagnostics LEDs remain lit only while the server is connected
to power.
For more information about the LEDs on the light path diagnostics panel, see “Light
path diagnostics LEDs” on page 16.
The following illustration shows the LEDs on the light path diagnostics panel.
Chapter 1. The System x3500 M4 server 15
OVER
SP EC
USB ports
Hard disk drive/RAID
Fan
Temperature
Microprocessor
Configuration
Memory
Power supply
PCI
System board
NMI
Over spec
Light path diagnostics LEDs: The following table describes the LEDs on the light
path diagnostics panel and suggested actions to correct the detected problems.
Table 2. Light path diagnostics panel LEDs
vFollow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
vIf an action step is preceded by "(Trained technician only)," that step must be performed only by a trained
technician.
LED Description Action
Hard disk drive/
RAID
A hard disk drive has failed or is
missing. A SAS controller or a
ServeRAID controller error has
occurred.
1. Check the LEDs on the hard disk drives for the drive with
a lit status LED and reseat the hard disk drive.
2. Reseat the hard disk drive backplane.
3. Check the LEDs near SAS controllers or ServeRAID
controllers and reseat the corresponding controllers.
4. For more information, see the “Hard disk drive problems”
under the Troubleshooting tables in the Problem
Determination and Service Guide.
5. If the error remains, replace the following components one
at a time, in the order listed, restarting the server after
each:
a. Replace the hard disk drive.
b. Replace the hard disk drive backplane.
c. Replace the SAS controller.
d. Replace the ServeRAID controller.
6. If the problem remains, go to http://www.ibm.com/systems/
support/supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
Fan
A fan has failed, is operating too
slowly, or has been removed. The
TEMP LED might also be lit.
1. Open the fan cage cover to reseat the failing fan (with lit
LED).
2. Replace the failing fan (see “Installing a simple-swap fan”
on page 63).
16 IBM System x3500 M4 Type 7383: Installation and User’s Guide