Lutron FCJS-010 Bruksanvisning
Lutron
Smarth hem
FCJS-010
Läs nedan 📖 manual på svenska för Lutron FCJS-010 (8 sidor) i kategorin Smarth hem. Denna guide var användbar för 3 personer och betygsatt med 4.5 stjärnor i genomsnitt av 2 användare
Sida 1/8
Radio Powr Savr
Occupancy
Sensor
Pico
Remote
Control
PowPak
Dimming
Module
30 ft
(9 m) max
40 ft (12 m)
30 ft (9 m)
PowPak
Dimming Module
Install in center of room to
maximize RF coverage.
A
Connect mains wiring (switched hot, neutral) to each fixture.
B
Connect 0 –10 V control (+ and – ) to each fixture.-
1
+
–
NEU
HOT
Class 2
MAINS
Fixture Earth
Green/Yellow
To additional 0 –10 V fixtures-
Neutral
Switched Line/Hot
Violet
Pink*
+
–
WARNING! Shock Hazard. May result in serious injury or death. Turn off power at circuit
breaker before installing the unit.
Sample
ballast shown
Start Here
Mount, Wire, and Install 0 –10 V Devices -
and Lighting Fixtures
Consult third-party device installation guide
2
A
PowPak Dimming Module with 0 –10 V can be installed on a junction box or marshalling box using the conduit nut (provided) or with mounting -
screws (not provided). The device must NOT be mounted inside a fixture or other metallic enclosure – only on the exterior of a fixture. Please
consult local and national electric codes for proper installation.
If installing unit inside a junction box, please see Application Note #423 (P/N 048423 at www.lutron.com).
B
Once installed, energize the PowPak Dimming Module with 0 –10 V .-
C
Use the Toggle button “ u” to toggle between high-end and OFF to verify ballast wiring.
D
Use the “Raise ▲
” and “Lower
Δ
” buttons to verify control wiring.
Install PowPak Dimming Module with 0 –10 V-
Suggested Installation Location: Center of room to ensure proper RF coverage of area.
Switched Line/Hot (Red)
–
Line/Hot
(Black)
To Fixtures
0 –10 V- to Fixtures*
Neutral (White)
+
Neutral
Junction Box
1/2 in (21 mm) Knockout Opening
Conduit Nut
RMJS-8T-DV-B / URMJS-8T-DV-B
Switched Line/Hot (Red)
–
Line/Hot
(Black)
To Fixtures
0 –10 V-
to Fixtures *
Neutral (White)
+
Neutral
Junction Box
1/2 in (21 mm) Knockout Opening
Conduit Nut
RMJS-8TN-DV-B
Switched Line / Hot (Red)
–
Line / Hot (Black)
To Emergency
Fixtures
0 –10 V- to
Emergency
Fixtures*
Neutral (White)
+
Neutral
Junction Box
1/2 in (21 mm)
Knockout Opening
Conduit Nut
Emergency
Backup
Generator
Automatic
Transfer
Switch
Regular
Utility Power
Neutral
120 / 277 V~ Normal Feed
Neutral
120 / 277 V~ Emergency Feed
Note: For periodic testing and maintanance of emergency systems, use the toggle button of
the RMJS-8T-DV-B-EM to ensure proper operation. Make sure PowPak buttons remain
accessible.
Note: Momentary power outages can envoke emergency mode on the dimming module. See
Troubleshooting section for details.
RMJS-8T-DV-B-EM
* Use 18 AWG to 16 AWG (0.75mm
2 to 1.5mm2) solid wire only
vive.lut n.comro
Programming with a Vive Hub
3
A
Use an iOS or Android ® ®
compatible device.
C
Open the app and follow
the instructions.
Note: For further information on set up,
programming, and troubleshooting with a
Vive system, please refer to the installation
instructions included with the Vive hub or
visit www.lutron.com/vive
Note: For programming the PowPak
Dimming Module without a Vive hub see
reverse side.
X
Vive
B
Download the Lutron
Vive app.
PowPak | Installation
Dimming Module with 0 –10 V-
English
All Wireless
Transmitters must
be installed within 30 ft
(9 m) of the PowPak Dimming
Module with 0 –10 V-.
0 –10 V- - Control: 10 V 60 mA
UL 2043 Plenum Rated
UL 924 Listed (RMJS-8T-DV-B-EM)
Compatible with ANSI E1.3 2001 (R2006), IEC 60929 Annex E
120 / 277 V~ 50 / 60 Hz 8 A
RMJS-8T-DV-B
URMJS-8T-DV-B
RMJS-8TN-DV-B
Important Notes: Please read before installing.
For installation by a qualified electrician in accordance with all local and
national electrical codes (including periodic testing and maintenance of
emergency systems).
• Note: Use copper conductors only.
• Check to see that the device type and rating is suitable for the application.
• DO NOT install if product has any visible damage.
• If moisture or condensation is evident, allow the product to dry completely
before installation.
• Operate between 32 °F and 104 °F (0 °C and 40 °C) ambient.
• 0% to 90% humidity, non-condensing.
• For indoor use only.
Note for Replacement:
RMxS and URMxS - the "S" model can replace the non-"S" model
041771
Rev. A
09/2020
Part of the Vive Family
120 / 277 V~ 50 / 60 Hz 8 A
RMJS-8T-DV-B-EM
IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS.
• Do not use outdoors.
• Do not mount near gas or electric heaters.
• Equipment should be mounted in locations and at heights where it will not be
subjected to tampering by unauthorized personnel.
• The use of accessory equipment not recommended by the manufacturer may
cause an unsafe condition.
• Do not use this equipment for other than its intended use.
SAVE THESE INSTRUCTIONS
Tes t
Link Cal. +
For each system, ensure that you have:
One PowPak Dimming Module At least one Wireless Transmitter At least one 0 –10 V Fluorescent Ballast or LED Driver-
Required Components
Radio Powr Savr Occupancy / Vacancy Sensor
(10 maximum)
Radio Powr Savr Daylight Sensor
(1 maximum)
Pico Remote Control
(10 maximum)
60 mA maximum for the control lines. Switches up to 8 A total.
May be pre-installed in light fixture.
Note: All drivers and ballasts used with Vive wireless controls must comply with the
limits for a Class A device, pursuant to Part 15 of the FCC rules.
PowPak Dimming Module with 0 –10 V-
(1 maximum)
Raise
Toggle
Lower
Load Status LED
Consult third-party 0 –10 V fixtures installation guide for fixture-specific wiring.-
For mounting and wiring best practices see Lutron Application Note #620 (P/N 048620).
+
Customer Assistance www.lutron.com/support
Wireless Controls: All lights
Default Functionality
Daylight Sensor
All lights dim in response to daylight.
On: Favorite 100% ; : 50%; Off: 0%
Occupancy Sensors
Occupied: Unoccupied All lights100% ; : All lights off
Lutron Electronics Co., Inc. | 7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
* This wire may be gray on older products or in retrofit applications.
PowPak | Installation
Programming without a Vive Hub
Dimming Module with 0 –10 V-
Part of the Vive Family
Start Here
Lutron, Pico, PowPak, Radio Powr Savr, and Vive are trademarks or registered trademarks of Lutron Electronics Co., Inc. in the US and/or other countries. ©2013 – 2020 Lutron Electronics Co., Inc.Safari is a trademark of Apple Inc., registered in the U.S. and other countries. All other product names, logos, and brands are property of their respective owners.
A On PowPak Dimming Module with
0 –10 V-, hold Toggle button “ u”
for 6 seconds until lights flash.
The Load Status LED will begin
flashing twice per second.
Associate Wireless Transmitters to
PowPak Dimming Module with 0 –10 V-
Before beginning this step, make sure that there are no other
PowPak modules being set up within the same building. It is
possible that wireless transmitters from other systems can be
incorrectly associated to this module.
1
C On PowPak Dimming Module with 0 –10 V , hold -Toggle
button “ u” for 6 seconds to save association. Lights will
flash and LED will quickly blink for 2seconds.
B Hold the indicated button on each transmitter for 6seconds.
Lights will flash to show that wireless transmitters have been
associated.
Test
Link
D Permanently install wireless transmitters (consult individual
component installation guides for information).
Low-End Trim
A
Enter low-end trim adjustment mode:
Press and hold the button “Lower
Δ
” on the fixture control for 12 seconds.
The lights will flash and the load status LED will begin flashing.
B
Adjust the low-end trim:
Use the Raise button “▲
” and button “Lower
Δ
” on the fixture control to adjust and set the
lights to the desired low-end (1 to 45%).
C
Save the low-end trim:
Press and hold the Toggle button “ u” for 6seconds to save setting.
The load status LED will begin flashing and then turn solid to indicate new level has been saved.
High-End Trim
A
Enter high-end trim adjustment mode:
Press and hold the button “Raise ▲
” on the fixture control for 12seconds.
The lights will flash and the load status LED will flash.
B
Adjust the high-end trim:
Use the Raise button “▲
” and button “Lower
Δ
” on the fixture control to adjust and set the
lights to the desired high-end (55 to 100%).
C
Save the high-end trim:
Press and hold the Toggle button “ u” for 6seconds to save setting.
The load status LED will begin flashing and then turn solid to indicate new level has been saved.
Set Low-End Trim and High-End Trim (Optional)
For best results, minimize the amount of sunlight entering the room before
performing the following procedures.
Notes
Depending on the fixture manufacturer or load, low-end trim and high-end trim
may need to be adjusted.
• Trim low-end to ensure a stable light level because some loads will flicker or drop out if
trimmed too low.
• Be sure that you can turn on the lights to the low-end trim level without any
abnormal operation.
• The factory default high-end trim is suitable for most applications but can be
adjusted as desired.
4
5Set Minimum Light Level (Optional)
Certain applications (e.g., hallways), may require that the lights never turn off. For these areas, activate Minimum Light Level
mode.
A
Enter minimum light level adjustment mode:
Press and hold Toggle button “ u” and button “Lower
Δ
” for 12 seconds. Lights will flash high-low-high and LED will begin
flashing.
If lights stop flashing and go to high-end, the minimum light level is set to OFF (default).
If lights stop flashing and go to low-end, the minimum light level is ON and set to low-end.
B
Change the minimum light level:
Press button “Raise ▲
” to set minimum light level to low-end.
Press button “Lower
Δ
” to set minimum light level to OFF.
C
Save the minimum light level:
Press and hold Toggle button “ u” for 6seconds. LED will quickly flash to indicate that new level has been saved.
Limited Warranty:
www.lutron.com/TechnicalDocumentLibrary/369-119_Wallbox_Warranty.pdf
For FCC/IC information: Please visit: www.lutron.com/fcc-ic
Calibrate the Radio Powr Savr Daylight Sensor
Daylight Sensor will control all wired fixtures equally.
A
Press and release the “Cal.” button on the Daylight Sensor.
B
Set lights in room to desired light level.
C
Press and hold the “Cal.” button for 6seconds.
D
Exit room for 5 minutes to complete calibration.
Note: When calibration has completed, all lights will flash and begin to respond to daylight.
Multiple Daylight Rows (Optional)
For every row of daylighting a separate PowPak Dimming Module with 0 –10 V must be -
used. For detailed setup refer to the tuning section of the Radio Powr Savr Daylight Sensor
installation guide.
• Select the PowPak Dimming Module with 0 –10 V that you want to adjust by pressing the -
toggle button.
Test
Link
2
Raise Lower
Favorite
Set a Favorite Light Level (Optional)
For Pico remote controls with a button.Favorite
A
Adjust lights to desired level:
Use the button “Raise ” or Lower button “ ” on the Pico
remote control.
B
Save favorite level:
Press and hold the button for 6seconds. The load will Favorite
flash 3 times to confirm that the Favorite level is saved.
3
Customer Assistance:
U.S.A., Canada, and the Caribbean: 1.844.LUTRON1
Mexico: +1.888.235.2910
Brazil: +55.1.3257.6745
Central / S. America: +1.610.282.6701
Other Countries: +1.610.282.3800
www.lutron.com/support
6Set Occupancy Light Levels (Optional)
Note: Unoccupied light level is always the minimum light level and cannot be adjusted.
A
Set desired occupancy light levels:
Use the buttonsRaise/Lower “▲ /
Δ
” on the PowPak Dimming Module with 0 –10 V- or the buttons Raise/Lower “ / ” on
all associated Pico Remote Controls to dim the lights to the desired level. Setting lights to OFF during this step will Note:
make that control module unaffected by occupancy (will function as vacancy only).
B
Save occupancy light levels:
Press and hold Test Lights On button for 6 seconds on any associated Radio Powr Savr Occupancy Sensor without a
button. Release when the sensor lens starts to flash.
Or, press and hold button for 6 seconds on any associated Radio Powr Savr Occupancy Sensor. Release when Lights On
the sensor lens starts to flash.
Customer Assistance www.lutron.com/support
Ballasts cannot be controlled
locally from PowPak Dimming
Module with 0 –10 V .-
• Ensure that the breaker(s) to the PowPak Dimming Module with 0 –10 V are energized.-
• Ensure that the PowPak Dimming Module with 0 –10 V switched hot lead is wired to the lighting fixture(s).-
• Ensure that the PowPak Dimming Module with 0 –10 V control lines are wired to the lighting fixture(s).-
Reset to factory defaults.
Lights do not dim as expected. • Ensure that 0 –10 V control lines are wired properly.-
• Ensure that fixture does not require an inverted signal (10 – 0 V control).-
Lights do not respond to Wireless
Transmitter(s).
• Ensure that the breaker(s) to the PowPak Dimming Module with 0 –10 V and ballasts are energized.-
• Ensure that Wireless Transmitters are associated to the PowPak Dimming Module with 0 –10 V-.
Reset to factory defaults.
Lights are unstable at low-end or
flash/flicker at turn-on or turn-off. • Adjust low-end trim.
Wireless Transmitter(s) cannot be
associated to PowPak Dimming
Module with 0 –10 V .-
• The maximum number of Wireless Transmitters have been associated to the PowPak Dimming Module with
0 –10 V-. To remove a previously set up Wireless Transmitter, tap a Wireless Transmitter button three times; on
the third tap hold for three seconds and then tap three more times.
PowPak is in emergency mode
(RMJS-8T-DV-B-EM only).
• In systems with a Vive hub: Contact Lutron Customer Assistance for further details.
• In systems without a Vive hub: Wait 90 minutes for the PowPak to return to normal operation.
PowPak will not go into
emergency mode
(RMJS-8T-DV-B-EM only).
• Contact Lutron Customer Assistance for further details.
Troubleshooting www.lutron.com/support
Reset Factory Defaults
Note: In some instances, it may be necessary to reset the PowPak
Dimming Module with 0 –10 V and connected devices back to -
factory default settings. Before beginning, make sure that all devices
are connected and powered.
A
Rapidly tap the Toggle button “ u” on the PowPak Dimming Module
3 times and hold on the fourth time until the LED begins to flash at
a rate of approximately 2 blinks every 1 second; then release the
Toggle button “ u” .
B
Within 3 seconds of the start of flashing of the LED on the PowPak,
rapidly tap the Toggle button “ u” on the PowPak Dimming Module
3 times again. Make sure to release the Toggle button “ u” after the
third press.
C
The LED will flash at a rate of 2 blink every 3 seconds and the
connected load will cycle 3 times to indicate the unit has been reset
to factory defaults.
Note: Any associations or programming previously set up with the
PowPak will be erased and will need to be re-programmed.
Détecteur
d’occupation
Radio Powr Savr
Télécommande
Pico
Module de
gradation
PowPak
9 m
(30 pi) max
12 m (40 pi)
9 m (30 pi)
Module de
gradation PowPak
À installer au centre de la pièce pour
maximiser la couverture RF.
A
Raccordez le câblage du secteur (conducteur commuté et neutre) sur
chaque applique.
B
Raccordez la commande de 0 –10 V (+ et – ) sur chaque applique.-
1
+
–
NEU
HOT
Class 2
MAINS
Terre de l’applique
Vert/Jaune
Vers d’autres appliques de 0 –10 V-
Neutre
Commutée
Ligne/Phase
Violet
Rose*
+
–
AVERTISSEMENT!
Risque d’électrocution. Peut causer des blessures graves ou la mort.
Coupez l’alimentation au niveau du disjoncteur avant d’installer l’unité.
Exemple de
ballast
représenté
Commencez ici
Monter, câbler et installer les appareils et
luminaires de 0 –10 V-
Consultez le guide d’installation des appareils tiers
2
A
Un module de gradation PowPak de 0 –10 V peut être installé sur un boîtier de raccordement ou un boîtier de regroupement en utilisant l’écrou de -
conduit (fourni) ou des vis de montage (non fournies). L’appareil NE doit PAS être monté à l’intérieur d’un luminaire ou d’un autre boîtier métallique – à
l’extérieur d’un luminaire. Veuillez consulter les codes électriques locaux et nationaux pour une installation correcte.
Si vous devez installer une boîte de jonction, veuillez consulter à la Note d’application no423 (no de pièce 048423 sur www.lutron.com).
B
Une fois installé, alimentez le module de gradation PowPak de 0 –10 V-.
C
Utilisez le bouton de « Alterner u » pour alterner entre le réglage haut et l’ARRÊT afin de vérifier le câblage du ballast.
D
Utilisez les boutons « Monter ▲
» et « Baisser
Δ
» pour vérifier le câblage de commande.
Installez le module de gradation PowPak de 0 –10 V-
Emplacement recommandé pour l’installation : Au centre de la pièce pour assurer une bonne couverture RF de l’espace.
Commutée
Ligne / Phase (Rouge)
–
Ligne / Phase
(Noir)
Vers les appliques
0 –10 V vers les appliques*-
Neutre (Blanc)
+
Neutre
Boîtier de raccordement
Entrée à perforer de 21 mm (1/2 po)
Écrou de conduit
RMJS-8T-DV-B / URMJS-8T-DV-B
Commutée
Ligne / Phase (Rouge)
–
Ligne / Phase
(Noir) Vers les
appliques
0 –10 V vers -
les appliques *
Neutre (Blanc)
+
Neutre
Boîtier de raccordement
Entrée à perforer de 21 mm (1/2 po)
Écrou de conduit
RMJS-8TN-DV-B
Commutée
Ligne / Phase (Rouge)
–
Ligne / Phase (Noir)
Vers les
appliques
0 –10 V -
vers les
appliques*
Neutre (Blanc)
+
Neutre
Boîtier de raccordement
Entrée à perforer de
21 mm (1/2 po)
Écrou de conduit
Générateur de
secours
Commutateur
de transfert
automatique
Alimentation
de service
régulière
Neutre
Alimentation normale de 120 / 277 V ~
Neutre
Alimentation de secours de 120 / 277 V~
Remarque: Pour le contrôle et l’entretien périodiques des systèmes de secours, utilisez le
bouton à bascule du RMJS-8T-DV-B-EM pour garantir le bon fonctionnement.
Assurez-vous que les boutons du PowPak restent accessibles.
Remarque: Les coupures de courant momentanées peuvent déclencher le mode de
secours sur la commande de luminaire. Voir la section pour plus Dépannage
d’informations.
RMJS-8T-DV-B-EM
* N’utilisez que du fil rigide de 0,75 mm
2 à 1,5 mm2 (18 AWG à 16 AWG)
vive.lut n.comro
Programmation avec un hub Vive
3
A
Utilisez un appareil
compatible avec iOS® ou
Android®.
C
Ouvrez l’application et
suivez les instructions. Remarque: Pour plus d’information sur
la configuration, la programmation et le
dépannage avec un système Vive, veuillez
vous reporter aux instructions d’installation
fournies avec le hub Vive ou consultez
www.lutron.com/vive
Remarque: Pour programmer le module
de gradation PowPak sans hub Vive,
consultez le verso.
X
Vive
B
Téléchargez l’application
Vive de Lutron.
PowPak | Installation
Module de gradation de 0 –10 V-
Français
Tous les
transmetteurs sans
fil doivent être installés
à moins de 9 m (30 pi) du
module de gradation PowPak de 0 –10 V .-
Commande de 0 –10 V : 10 V 60 mA- -
Conformité plénum de la norme UL 2043
Certifié UL924 (RMJS-8T-DV-B-EM)
Compatible avec ANSI E1.3 2001 (R2006), IEC 60929 Annexe E
120 / 277 V~ 50 / 60 Hz 8 A
RMJS-8T-DV-B
URMJS-8T-DV-B
RMJS-8TN-DV-B
Remarques importantes : Veuillez lire avant l’installation.
À faire installer par un électricien qualifié conformément à tous les codes
électriques locaux et nationaux (y compris pour le contrôle et l’entretien
périodiques des systèmes de secours).
• Remarque: N’utilisez que des conducteurs en cuivre.
• Veillez à ce que le type d’appareil et sa caractéristique nominale
conviennent à l’application.
• Ne l’installez PAS si le produit présente des dommages visibles.
• Si de l’humidité ou de la condensation est apparente, laissez le produit
sécher avant son installation.
• Fonctionne de 0 °C à 40 °C (32 °F à 104 °F) température ambiante.
• 0 % à 90 % d’humidité, sans condensation.
• Utilisation à l’intérieur seulement.
Remarque pour les remplacements :
RMxS et URMxS - le modèle «S» peut remplacer le modèle non-«S»
041771
Rev. A
09/2020
Membre de la famille Vive
120 / 277 V~ 50 / 60 Hz 8 A
RMJS-8T-DV-B-EM
CONSIGNES DE SÉCURITÉ IMPORTANTES
Lorsque vous utilisez des appareils électriques, il est important de toujours respecter
les consignes de sécurité élémentaires, notamment:
LISEZ ET RESPECTEZ TOUTES LES
CONSIGNES DE SÉCURITÉ.
• N’utilisez pas cet équipement à l’extérieur.
• Ne l’installez pas à proximité de radiateurs électriques ou au gaz.
• L’équipement doit être installé dans des endroits et à des hauteurs où il ne sera pas
manipulé par des personnes non-autorisées.
• L’utilisation d’accessoires non recommandés par le fabricant peut provoquer une
situation dangereuse.
• N’utilisez pas cet appareil pour d’autres fins que celles prévues.
CONSERVEZ CES CONSIGNES
Tes t
Link Cal. +
Pour chaque système, assurez-vous d’avoir:
Un module de gradation PowPak Au moins un transmetteur sans fil Au moins un ballast fluorescent ou un pilote de DEL de 0 –10 V -
Composants requis
Détecteur d’occupation/inoccupation
Radio Powr Savr (10 maximum)
Détecteur de lumière du jour
Radio Powr Savr (1 maximum)
Télécommande Pico
(10 maximum)
60 mA maximum pour les lignes de commande. Commute jusqu’à 8 A au total.
Peut être préinstallé dans une applique.
Remarque: Tous les pilotes et ballasts utilisés avec les commande Vive sans fil
doivent être conformes aux limites d’un appareil de Classe A en vertu de la partie
15 des règles de la FCC.
Module de gradation PowPak de 0 –10 V-
(1 maximum)
Monter
Alterner
Baisser
DEL de l’état
de la charge
Consultez le guide d’installation des appliques tierces de 0 –10 V- pour le câblage spécifique aux appliques.
Pour les meilleures pratiques de montage et de câblage, consultez la note d’application 620
(no de pièce048620) de Lutron.
+
Assistance à la clientele www.lutron.com/support
Commandes sans fil : Toutes les lumières
Fonctionnalité par défaut
Détecteur de lumière du jour
Les lumières se tamisent en réaction à la lumière du jour.
Allumé : Favori Éteint 100 % ; : 50 % ; : 0 %
Détecteurs d’occupation
Occupé : Toutes les lumières à 100 %; : Inoccupé Toutes les lumières éteintes
Lutron Electronics Co., Inc. | 7200 Suter Road
Coopersburg, PA 18036-1299, É.-U.
* Ce fil borne peut être gris(e) sur les produits plus anciens ou dans les applications
de rénovation.
Produktspecifikationer
Varumärke: | Lutron |
Kategori: | Smarth hem |
Modell: | FCJS-010 |
Behöver du hjälp?
Om du behöver hjälp med Lutron FCJS-010 ställ en fråga nedan och andra användare kommer att svara dig
Smarth hem Lutron Manualer
27 December 2024
19 September 2024
Smarth hem Manualer
- Smarth hem Bosch
- Smarth hem IKEA
- Smarth hem Philips
- Smarth hem Panasonic
- Smarth hem Gigaset
- Smarth hem Honeywell
- Smarth hem Abus
- Smarth hem Acer
- Smarth hem Ajax
- Smarth hem Alecto
- Smarth hem Aluratek
- Smarth hem Brennenstuhl
- Smarth hem Hikvision
- Smarth hem Nedis
- Smarth hem Livoo
- Smarth hem Manta
- Smarth hem Asus
- Smarth hem Caliber
- Smarth hem Renkforce
- Smarth hem Niceboy
- Smarth hem Blaupunkt
- Smarth hem TP Link
- Smarth hem Lenovo
- Smarth hem Ezviz
- Smarth hem Trust
- Smarth hem Elro
- Smarth hem EMOS
- Smarth hem KlikaanKlikuit
- Smarth hem KKT Kolbe
- Smarth hem Denver
- Smarth hem Imou
- Smarth hem Hama
- Smarth hem Byron
- Smarth hem Gardena
- Smarth hem Smartwares
- Smarth hem Profile
- Smarth hem Salus
- Smarth hem Eufy
- Smarth hem Steren
- Smarth hem Burg-Wachter
- Smarth hem Linksys
- Smarth hem Sanus
- Smarth hem Netgear
- Smarth hem LevelOne
- Smarth hem DIO
- Smarth hem Laica
- Smarth hem Hive
- Smarth hem Danfoss
- Smarth hem Netatmo
- Smarth hem NGS
- Smarth hem Hager
- Smarth hem FireAngel
- Smarth hem Chacon
- Smarth hem Reolink
- Smarth hem Tesla
- Smarth hem Rademacher
- Smarth hem Busch-Jaeger
- Smarth hem D-Link
- Smarth hem Logicom
- Smarth hem Tenda
- Smarth hem Vivax
- Smarth hem Delta Dore
- Smarth hem Niko
- Smarth hem Rain Bird
- Smarth hem Gira
- Smarth hem Jung
- Smarth hem Ring
- Smarth hem ATen
- Smarth hem Nobo
- Smarth hem Digi
- Smarth hem Fibaro
- Smarth hem Ranex
- Smarth hem Easy Home
- Smarth hem Qnect
- Smarth hem Nexa
- Smarth hem Fanvil
- Smarth hem Dormakaba
- Smarth hem EQ3
- Smarth hem Homematic IP
- Smarth hem Home Easy
- Smarth hem X-Sense
- Smarth hem SPC
- Smarth hem Crestron
- Smarth hem Chuango
- Smarth hem ETiger
- Smarth hem Berker
- Smarth hem Drayton
- Smarth hem Aqara
- Smarth hem Ferguson
- Smarth hem Redmond
- Smarth hem KanexPro
- Smarth hem Shelly
- Smarth hem Paulmann
- Smarth hem Vimar
- Smarth hem Kogan
- Smarth hem Intertechno
- Smarth hem V-Tac
- Smarth hem EQ-3
- Smarth hem Schellenberg
- Smarth hem EVOLVEO
- Smarth hem Aeotec
- Smarth hem Gossen Metrawatt
- Smarth hem Brilliant
- Smarth hem Govee
- Smarth hem Nous
- Smarth hem SEC24
- Smarth hem Athom
- Smarth hem Casambi
- Smarth hem Tellur
- Smarth hem TELE System
- Smarth hem Airthings
- Smarth hem SwitchBot
- Smarth hem Nanoleaf
- Smarth hem Mach Power
- Smarth hem Sonoff
- Smarth hem Blebox
- Smarth hem Meross
- Smarth hem Middle Atlantic
- Smarth hem Origin Acoustics
- Smarth hem Winland
Nyaste Smarth hem Manualer
29 December 2024
28 December 2024
27 December 2024
27 December 2024
27 December 2024
26 December 2024
24 December 2024
24 December 2024
24 December 2024
20 December 2024