Sida 1/9
OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
MILLIAMP CLAMP METER
PINCE AFFICHEUR DE COURANT MILLIAMPÈRES
MILIAMPERÍMETRO DE PINZA
Cat. No.
No de cat.
2231-20
H O L D R OZ E
23
H O L D R O
Z E
IMPORTANT SAFETY INSTRUCTIONS
WARNING READ ALL SAFETY WARNINGS AND ALL INSTRUCTIONS.
Failure to follow the warnings and instructions may result in electric shock, re and/or serious
injury, as well as instrument damage and/or damage to the equipment being tested.
Save these instructions - This operator’s manual contains important safety and operating
instructions for the MILWAUKEE Milliamp Clamp Meter. Before using, read this operators
manual and all labels on the Clamp Meter.
GENERAL SPECIFICATIONS FUNCTIONAL DESCRIPTION
Accuracy is speci ed for 1 year after calibration, at
operating temperatures of 64°F to 82°F (18°C to
28°C), with relative humidity at 0 % to 85 % (NON-
CONDENSING).
Jaw Opening (maximum conductor size) ....
0.23" (6 mm)
Temperature ....
Operating: 14°F to 122°F (-10°C to 50°C)
Storage: -40°F to 140°F (-40°C to 60°C)
Temperature Coefficient .... 0.1 x (specified
accuracy)/°C (<18°C or >28°C)
Operating Altitude.... 0 to 2,000 meters
Drop Test .... 1 Meter
Battery .... 2 AA NEDA 15A, IEC LR6, 1.5V Alkaline
Battery Life .... Approx. 25 hours
Safety Compliances ....EN61010-1, UL 61010-1,
IEC 61010-2-32 (Clamp Assemblies),
IEC/EN 61010-1 2nd Edition for measurement
Category II, 60 V, Pollution Degree 2,
EMC EN61326-1
Certi cations .... cULus, CE
1. Worklight LED
2. Clamp storage
3. Low battery indicator
4. Primary measurement
5. Hold indicator
6. Worklight on/o
7. Power button
8. Hold button
9. Zero button
10. Units indicator
11. 4 to 20 mA Span
Percentage
12. Tactile barrier
13. Clamp
DANGER
Use only for tests on DC circuits. Do not use to test AC current.
Do not make tests on non-insulated conductors.
Do not attempt to make measurement in the presence of ammable gasses. Otherwise, the
use of the instrument may cause sparking, which can lead to an explosion.
Transformer jaw tips are designed not to short the circuit under test. If equipment under test
has exposed conductive parts, however, extra precaution should be taken to minimize the
possibility of shorting.
Never attempt to use the instrument if its surface or your hand is wet.
Do not exceed the maximum allowable input of any measuring range.
Check meter functionality on a known circuit rst. Never assume meter is working. Assume
circuits are live until they can be proven de-energized.
Do not ground yourself while measuring. Avoid body contact with earthed or grounded sur-
faces such as pipes, radiators, ranges and refrigerators.
Never open the battery cover during a measurement.
The instrument is to be used only in its intended applications or conditions. Otherwise, safety
functions equipped with the instrument doesn’t work, and instrument damage or serious
personal injury may be caused.
To reduce the risk of injury from shock and arc blasts, always wear personal protective
equipment where live conductors are exposed.
WARNING
Never attempt to make measurement if any abnormal conditions, such as broken case and
exposed metal parts are found on the instrument.
Verify proper operation on a known source before use or taking action as a result of the in-
dication of the instrument.
Do not install substitute parts or make any modi cation to the instrument. For repair or re-
calibration, return the meter to a factory Service/Sales Support Branch or authorized service
station.
Do not try to replace the batteries if the surface of the instrument is wet.
Disconnect all the cords and cables from the object under test and power o the instrument
before opening the battery cover for battery replacement.
This meter is designed to be powered by 2-AA batteries properly inserted into the MILWAUKEE
Clamp Meter. Do not attempt to use with any other voltage or power supply.
Install battery according to polarity (+ and –) diagrams.
Do not leave batteries within the reach of children.
Do not mix new and used batteries. Do not mix brands (or types within brands) of batteries.
Properly dispose of used batteries.
Do not incinerate or dismantle batteries.
Under abusive conditions, liquid may be ejected from the battery, avoid contact. If contact
accidentally occurs, ush with water. If liquid contacts eyes, additionally seek medical help.
Liquid ejected from the battery may cause irritation or burns.
CAUTION
Do not expose the instrument to the direct sun, high temperature and humidity or dew fall.
Altitude 2000m or less. Appropriate operating temperature is within 14°F and 122°F (-10°C
and 50°C).
This instrument isn’t dust & water proofed. Keep away from dust and water.
Be sure to power o the instrument after use. When the instrument will not be in use for a long
period, place it in storage after removing the batteries.
Use a cloth dipped in water or neutral detergent for cleaning the instrument. Do not use
abrasives or solvents.
1
3
5
4
2
6
7
8
9
10
11
13
4 to 20 mA Span Percentage
22 mA 110%
20 mA 100%
16 mA 75%
12 mA 50%
8 mA 25%
4 mA 0%
0 mA -25%
12
Range Resolution Accuracy
0.00 mA to 3.99 mA 0.01 mA ± 0.2% ± 10 digits
4.00 mA to 21.49 mA 0.01 mA ± 0.2% ± 5 digits
21.5 mA to 99.9 mA 0.1 mA ± 1.0% ± 5 digits
45
OPERATION
ASSEMBLY
SYMBOLOGY
Changing the Batteries
To avoid false readings, replace batteries as soon
as the low battery indicator
is displayed.
1. Turn the meter OFF and remove the clamp from
the conductor..
2. Unscrew and re-
move battery door.
3. Insert two (2) AA
batteries, accord-
ing to the polarity
marked in the bat-
tery compartment
4. Close the battery
door and tighten
screw securely.
WARNING
To avoid an electrical hazard, turn the meter
OFF and remove the clamp from the conduc-
tor before replacing batteries.
Read Operator’s Manual
Volts
Direct Current
Double Insulation
Do not apply around or remove from
HAZARDOUS LIVE conductors.
Danger, Warning, or Caution
Battery
European Conformity Mark
Underwriters Laboratories, Inc.,
United States and Canada
1Canadian Conformity Mark
Cat II Classi cation of transient over-
voltages, based on nominal line
voltage to earth.
Do not dispose of this product as
unsorted municipal waste. Contact
quali ed recycler for disposal.
DANGER To avoid electrical shock:
Use only for tests on 60V Cat II DC circuits.
Do not use to test AC current.
Do not make tests on non-insulated con-
ductors.
Do not use with the battery cover removed.
CAUTION Maximum conductor size
is 0.23" (6 mm) diameter. During mea-
surement, keep the jaws fully closed to ensure
accurate measurements.
Measuring
1. Remove the clamp
from the clamp storage
pocket.
2. Press the power button
to turn on the meter. Al-
ways press the ZERO
button before placing
the clamp around a
conductor to take a
new measurement.
3. Keep ngers behind
tactile barrier.
4. Open the jaws and clamp them around the con-
ductor under test.
NOTE: Do not clamp over more than one wire
at a time. Irregular results will occur.
5. The reading is displayed. A negative number
indicates current ow in the opposite direction
of the arrows on the clamp.
6. Press the power button to turn off the meter.
Remove the jaws from the conductor.
Worklight LED Button
To turn the worklight on and off, press the
button.
ZERO Button
Always press the ZERO button before clamping
around a conductor. Pressing the ZERO button
removes the residual DC current oset to ensure
a more accurate reading.
HOLD Button
Press the HOLD button to freeze the reading. The
reading will be held regardless of subsequent varia-
tion in input. HOLD is displayed with the reading.
To exit Hold mode, press the HOLD button again.
Sleep Mode
The display will turn oabout 5 minutes after the
last button operation to conserve battery life. Press
any button to turn the display back on.
Auto Power O
The meter will completely power off about 15
minutes after the last button operation to conserve
battery life.
1.5V
1.5V
FIVE YEAR TOOL LIMITED
WARRANTY
MILWAUKEE Test & Measurement Product (including
bare tool, M12™ battery pack(s) and battery charger)
is warranted to the original purchaser only to be free
from defects in material and workmanship. Subject to
certain exceptions, MILWAUKEE will repair or replace
any part on this product which, after examination, is
determined by MILWAUKEE to be defective in material
or workmanship for a period of ve (5) years* after the
date of purchase. Return of the Test & Measurement
tool to the nearest Milwaukee Electric Tool Corporation
- factory Service Center, freight prepaid and insured
is required. A copy of the proof of purchase should be
included with the return product. This warranty does not
apply to damage that MILWAUKEE determines to be
from repairs made or attempted by anyone other than
MILWAUKEE authorized personnel, misuse, alterations,
abuse, normal wear and tear, lack of maintenance, or
accidents.
* See separate & distinct CORDLESS BATTERY PACK
LIMITED WARRANTY statement for the warranty period
of the LITHIUM-ION battery pack that ships with Test &
Measurement Product. *Alkaline battery that ships with
Test & Measurement Product is separately warranted
by the alkaline battery manufacturer.
*The warranty period for a Voltage Detector with Work
Light – 2201 20, Voltage Detector with LED – 2202-20
or M12™ 2-Beam Plumb Laser 2230 20 is one (1)
year from the date of purchase.
Warranty Registration is not necessary to obtain the ap-
plicable warranty on MILWAUKEE product. The manu-
facturing date of the product will be used to determine
the warranty period if no proof of purchase is provided
at the time warranty service is requested.
ACCEPTANCE OF THE EXCLUSIVE REPAIR AND
REPLACEMENT REMEDIES DESCRIBED HEREIN
IS A CONDITION OF THE CONTRACT FOR THE
PURCHASE OF EVERY MILWAUKEE PRODUCT. IF
YOU DO NOT AGREE TO THIS CONDITION, YOU
SHOULD NOT PURCHASE THE PRODUCT. IN NO
EVENT SHALL MILWAUKEE BE LIABLE FOR ANY
INCIDENTAL, SPECIAL, CONSEQUENTIAL OR PUNI-
TIVE DAMAGES, OR FOR ANY COSTS, ATTORNEY
FEES, EXPENSES, LOSSES OR DELAYS ALLEGED
TO BE AS A CONSEQUENCE OF ANY DAMAGE TO,
FAILURE OF, OR DEFECT IN ANY PRODUCT IN-
CLUDING, BUT NOT LIMITED TO, ANY CLAIMS FOR
LOSS OF PROFITS. SOME STATES DO NOT ALLOW
THE EXCLUSION OR LIMITATION OF INCIDENTAL
OR CONSEQUENTIAL DAMAGES, SO THE ABOVE
LIMITATION OR EXCLUSION MAY NOT APPLY TO
YOU. THIS WARRANTY IS EXCLUSIVE AND IN LIEU
OF ALL OTHER WARRANTIES, WRITTEN OR ORAL.
TO THE EXTENT PERMITTED BY LAW, MILWAUKEE
DISCLAIMS ANY IMPLIED WARRANTIES, INCLUDING
WITHOUT LIMITATION ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICU-
LAR USE OR PURPOSE; TO THE EXTENT SUCH
DISCLAIMER IS NOT PERMITTED BY LAW, SUCH
IMPLIED WARRANTIES ARE LIMITED TO THE DURA-
TION OF THE APPLICABLE EXPRESS WARRANTY
AS DESCRIBED ABOVE. SOME STATES DO NOT
ALLOW LIMITATIONS ON HOW LONG AN IMPLIED
WARRANTY LASTS, SO THE ABOVE LIMITATION
MAY NOT APPLY TO YOU, THIS WARRANTY GIVES
YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO
HAVE OTHER RIGHTS WHICH VARY FROM STATE
TO STATE.
This warranty applies to product sold in the U.S.A. and
Canada only.
MAINTENANCE
WARNING To reduce the risk of per-
sonal injury and damage, never immerse your
tool in liquid or allow a liquid to ow inside it.
WARNING To reduce the risk of injury,
always remove the batteries from the tool
before performing any maintenance. Never
disassemble the tool. Contact a MILWAUKEE
service facility for ALL repairs.
Cleaning
Clean dust and debris from tool. Keep tool clean, dry
and free of oil or grease. Use only mild soap and a
damp cloth to clean the tool since certain cleaning
agents and solvents are harmful to plastics and other
insulated parts. Some of these include gasoline,
turpentine, lacquer thinner, paint thinner, chlorinated
cleaning solvents, ammonia and household deter-
gents containing ammonia. Never use ammable or
combustible solvents around tools.
Repairs
For repairs, return the tool to the nearest service
center listed on the back cover of this operator's
manual.
Maintaining Tool
Keep your tool in good repair by adopting a regular
maintenance program. After six months to one year,
depending on use, return the tool to a MILWAUKEE
service facility for repairs.
If the tool does not start or operate at full power
with new batteries, clean the contacts on the battery
door. If the tool still does not work properly, return
the tool to a service facility for repairs.MILWAUKEE
ACCESSORIES
For a complete listing of accessories refer to your
MILWAUKEE Electric Tool catalog or go online
to www.milwaukeetool.com. To obtain a catalog,
contact your local distributor or service center.
WARNING Always remove batteries be-
fore changing or removing accessories. Only
use accessories speci cally recommended
for this tool. Others may be hazardous.