OPERATOR'S MANUAL
MANUEL de L'UTILISATEUR
MANUAL del OPERADOR
Cat. No.
No de Cat.
2267-20
2268-20
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S
MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN
COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL
MANUAL DEL OPERADOR.
Infrared Temp-Guns
Temp-Guns™ à infrarouge
Termómetros infrarrojos Temp-Guns™
2
IMPORTANT SAFE
4
FUNCTIONAL DESCRIPTION Specications
IR Temperature range:
For 2267-20: -30°C to 400°C (-22°F to 752°F)
For 2268-20: -30°C to 550°C (-22°F to 1022°F)
IR Accuracy:
For 2267-20:
-30°C to -18°C (-22°F to 0°F): ±2.0°C (4°F) + 0.1°C / 1°C
-18°C to 0°C (0°F to 32°F): ±2.5°C (5°F)
0°C to 400°C (32°F to 752°F): ±2.0°C (4°F) or 2.0%
of reading, whichever is greater
For 2268-20:
-30°C to -18°C (-22°F to 0°F): ±2.0°C (4°F) + 0.1°C / 1°C
-18°C to 10°C (0°F to 50°F): ±2.5°C (5°F)
10°C to 550°C (50°F to 1022°F): ±1.8°C (4°F) or 1.8%
of reading, whichever is greater
*Assume ambient operating temperature of 23°C ±2°C
(70°F to 77°F)
Repeatability: ±0.8% OR ±1°C (±2°F)
(whichever is greater)
Temperature display resolution:
0.1°C/°F in Primary and Secondary
Distance to spot (90% energy):
For 2267-20: 10 to 1
For 2268-20: 12 to 1
Emissivity: 0.95
Response time:<500 msec
Spectral response: 8 to 14µm
Drop: 2 meters
Laser Type: Class II
Max Power: <1mW
Wavelength: 630-670 nm
Operating temperature: 0°c to 50°C (32°F to 122°F)
Storage temperature: -20°C to 60°C (-4°F to 140°F)
without battery
Relative humidity: 10 to 85% at 25°C, decreasing
linearly to 10 to 45% at 50°C
Voltage: 9 DC (one (1) 9V battery)
Battery life: Greater than 12 hrs with all functions
NOTE: 2267-20 and 2268-20 may not meet its stated
accuracy when exposed to 80-500MHz at 3V/m.
ASSEMBLY
Loading/Changing the Battery
1. Using a at screwdriver,
rotate the battery door
lock to the unlocked
position and open the
battery door.
2. Connect one (1) 9V
battery to the connector
block. Fit the battery
into the compartment.
3. Close the battery door.
Turn the battery door
lock to the locked position.
Selecting Celsius or Fahrenheit
To set the temperature scale, pull the trigger and
then press the SET button three times. Press the
buttons above the up and down arrows to toggle
between °C and °F. Wait 5 seconds for the setting
to save and exit.
Setting the Laser Lock
To turn the laser on and off, pull the trigger and
then press the SET button four times. Press the
buttons above the up and down arrows to toggle
between ON and OFF. Wait 5 seconds for the set-
ting to save and exit.
5
6
1. Laser window
2. 2267-20 nameplate
3. 2268-20 nameplate
4. Trigger
5. Display
6. Mode/Set/Alarm Buttons
7. Battery door lock
8. Battery door
9. Battery indicator
10. Hold indicator
11. Laser active indicator
12. Trigger lock indicator
13. Alarm indicator
14. °C or °F indicator
15. Primary measurement
16. Secondary measurement
17. Mode indicator
10
11
12
15
16
17
13
9
14
3
2
4
8
7
1
3
SYMBOLOGY
Volts
Direct Current
CAUTION Laser Light - Do Not
Stare Into Beam
Laser product
Avoid Exposure: Laser Radiation Is
Emitted From This Aperture
To reduce the risk of injury, user must
read operator’s manual.