Sida 1/14
Hydroxyl Generator
Air Treatment System
HG1500
User Manual
IMPORTANT SAFETY INSTRUCTIONS
Carefully read the important safety and maintenance information.
Keep these instructions for future reference.
These instructions contain important safety and operating information for
your Newaire HG1500 Hydroxyl Generator. Please contact us directly with
questions you may have regarding the safe operation and/or maintenance.
Toll Free #: 1-877-646-9663
Important Safety Information 2 ..................................................................................................................
Handling and Disposal of Mercury 4 ..........................................................................................................
FAQs 5 ........................................................................................................................................................
Location of Controls 6 ................................................................................................................................
Operation 7 .................................................................................................................................................
Replacing the Carbon Filters 8 ...................................................................................................................
Replacing the UV Bulbs 9 ..........................................................................................................................
Cleaning 11 ................................................................................................................................................
Replacement Parts 11 ................................................................................................................................
Specications 12 ........................................................................................................................................
Troubleshooting 12 .....................................................................................................................................
Limited Warranty 13 ...................................................................................................................................
Table of Contents
Important Safety Information
DANGEROUS VOLTAGE: The lightning flash with
arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of uninsulated
dangerous voltage within the product’s enclosure that
may be of sufficient magnitude to constitute a risk of
electric shock to persons.
WARNING: TO PREVENT FIRE OR SHOCK HAZARD, DO NOT
EXPOSE THIS UNIT TO RAIN OR MOISTURE.
WARNING: DO NOT look directly at UV bulbs.
WARNING: Use this Hydroxyl Generator only for its intended
purpose as described in this Owner’s Manual.
ATTENTION: The exclamation point within an equilateral
triangle is intended to alert the user to the presence
of important operating and maintenance (servicing)
instructions in the literature accompanying this product.
FCC WARNING: This equipment may generate or use radio
frequency energy. Changes or modifications to this equipment
may cause harmful interference unless the modifications are
expressly approved in the instruction manual. The user could lose
the authority to operate this equipment if an unauthorized change
or modification is made.
This device complies with part 15 of the FCC Rules. Operation
is subject to the following two conditions: (1) This device may
not cause harmful interference, and (2) this device must accept
any interference received, including interference that may cause
undesired operation.
NOTE: This equipment has been tested and found to comply with
the limits for a Class B digital device, pursuant to part 15 of the FCC
Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy
and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning
the equipment off and on, the user is encouraged to try to correct
the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
INDUSTRY CANADA NOTICE:
This device complies with Industry Canada Iicense-exempt RSS
standard(s). Operation is subject to the following two conditions:
1. This device may not cause interference, and
2. This device must accept any interference, including interference
that may cause undesired operation of the device.
CAN ICES-3(B)/NMB-3(B)
Important Safety Information
Standard safety precautions must always be followed to
reduce the risk of re, electric shock, and injury to persons,
including the following:
1. Read these Instructions.
2. Keep these Instructions.
3. Heed all Warnings.
4. Follow all Instructions.
5. Do not use this apparatus in or near water.
6. Clean only with a damp cloth.
7. Do not block any of the ventilation openings. Install in
accordance with the Manufacturer’s instructions.
8. Do not install near any heat sources such as radiators,
heat registers, stoves, or other apparatus (including
ampliers) that produce heat.
9. Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades
with one wider than the other. A grounding type plug has
two blades and a third grounding prong. The wide blade
or the third prong are provided for your safety. When the
provided plug does not t into your outlet, consult an
electrician for replacement of the obsolete outlet.
10. Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the
point where they exit from the apparatus.
11. Only use attachments/accessories specified by the
manufacturer.
12. Use only with a cart, stand, tripod, bracket,
or table specied by the manufacturer, or
sold with the apparatus. When a cart is
used, use caution when moving the cart/
apparatus combination to avoid injury
from tip-over.
13. Unplug this apparatus during lightning
storms or when unused for long periods of time.
14. Refer all servicing to qualied service personnel. Servicing
is required when the apparatus has been damaged in any
way, such as power-supply cord or plug is damaged, liquid
has been spilled or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.
15. WARNING: To reduce the risk of re or electric shock,
do not expose this apparatus to rain or moisture. Do not
place objects lled with water, such as a vase, on the
apparatus.
16. The AC mains plug is used as the power disconnect
device and it should remain readily accessible and
operable during intended use. In order to completely
disconnect the apparatus from power, the mains plug
should be completely removed from the AC outlet socket.
17. Keep the cord out of heavy trafc areas. To avoid re
hazard, NEVER put the cord under rugs, near heat
registers, radiators, stoves, or heaters.
18. DO NOT operate any generator with a damaged cord
or plug, if motor fan fails to rotate, after the generator
malfunctions, or if it has been dropped or damaged in any
manner. Return generator to manufacturer or authorized
repair facility for examination, electrical or mechanical
adjustment, or repair.
19. Do not leave the generator in use unattended around
those requiring close supervision.
20. WARNING! Always unplug the generator before moving
it, cleaning, or whenever the generator is not in use. Be
sure to pull by the plug and not the cord.
21. This Hydroxyl Generator is for Indoor Use Only.
22. Do not attempt to repair or adjust any electrical or
mechanical functions on this unit other than the UV
bulbs and Carbon Filters. Doing so will void your
warranty. All servicing should be performed by qualied
personnel only.
23. Do not place anything on top of generator.
24. Do not plug the cord in with wet hands: electric shock
could result.
25. NEVER use detergents, gasoline, glass cleaner, furniture
polish, paint thinner or other household solvents to
clean any part of the generator.
26. See separate safety instructions (pages 4 and 5) for
replacing the UV Lamp with mercury.
27. For General Ventilating Use Only. Do Not Use to Exhaust
Hazardous or Explosive Materials and Vapors.
PLEASE READ AND SAVE THESE
IMPORTANT SAFETY INSTRUCTIONS
Produktspecifikationer
Varumärke: | Newaire |
Kategori: | Luftrenare |
Modell: | HG1500 |
Behöver du hjälp?
Om du behöver hjälp med Newaire HG1500 ställ en fråga nedan och andra användare kommer att svara dig
Luftrenare Newaire Manualer
4 September 2024
Luftrenare Manualer
- Luftrenare Electrolux
- Luftrenare Samsung
- Luftrenare Xiaomi
- Luftrenare LG
- Luftrenare Bosch
- Luftrenare AEG
- Luftrenare IKEA
- Luftrenare Braun
- Luftrenare Philips
- Luftrenare Panasonic
- Luftrenare BEKO
- Luftrenare Delonghi
- Luftrenare Honeywell
- Luftrenare JVC
- Luftrenare Karcher
- Luftrenare Miele
- Luftrenare Toshiba
- Luftrenare Unold
- Luftrenare Tefal
- Luftrenare Air-O-Swiss
- Luftrenare Airfree
- Luftrenare Argo
- Luftrenare Aeris
- Luftrenare WDH
- Luftrenare Shark
- Luftrenare GE
- Luftrenare Sharp
- Luftrenare Holmes
- Luftrenare Klarstein
- Luftrenare Gorenje
- Luftrenare Hitachi
- Luftrenare Hoover
- Luftrenare Breville
- Luftrenare Innoliving
- Luftrenare Tristar
- Luftrenare Domo
- Luftrenare Rowenta
- Luftrenare Livoo
- Luftrenare OBH Nordica
- Luftrenare Beurer
- Luftrenare Hisense
- Luftrenare Dyson
- Luftrenare Bestron
- Luftrenare Oster
- Luftrenare VAX
- Luftrenare Kodak
- Luftrenare Scarlett
- Luftrenare Taurus
- Luftrenare Russell Hobbs
- Luftrenare Lanaform
- Luftrenare Blaupunkt
- Luftrenare Sunbeam
- Luftrenare Medisana
- Luftrenare Danby
- Luftrenare Stirling
- Luftrenare Daikin
- Luftrenare Elro
- Luftrenare EMOS
- Luftrenare Gemini
- Luftrenare Bissell
- Luftrenare Eldom
- Luftrenare Maxxmee
- Luftrenare TCL
- Luftrenare Bionaire
- Luftrenare Lasko
- Luftrenare Dimplex
- Luftrenare Suntec
- Luftrenare Profile
- Luftrenare Solis
- Luftrenare Malloca
- Luftrenare Falmec
- Luftrenare Haier
- Luftrenare Steba
- Luftrenare Bort
- Luftrenare Ideal
- Luftrenare Homedics
- Luftrenare Soehnle
- Luftrenare Royal Sovereign
- Luftrenare Maxwell
- Luftrenare Zelmer
- Luftrenare Ardes
- Luftrenare ETA
- Luftrenare Stadler Form
- Luftrenare Heylo
- Luftrenare Proficare
- Luftrenare Ufesa
- Luftrenare Vicks
- Luftrenare Wilfa
- Luftrenare Olimpia Splendid
- Luftrenare Trotec
- Luftrenare Fellowes
- Luftrenare Qlima
- Luftrenare Duux
- Luftrenare Dirt Devil
- Luftrenare Hombli
- Luftrenare Sygonix
- Luftrenare Habitat
- Luftrenare Hunter
- Luftrenare Gastroback
- Luftrenare Sauber
- Luftrenare Mill
- Luftrenare Reer
- Luftrenare Tesla
- Luftrenare Alen
- Luftrenare Levoit
- Luftrenare Winix
- Luftrenare Leifheit
- Luftrenare Fuave
- Luftrenare Leitz
- Luftrenare Instant Pot
- Luftrenare Boneco
- Luftrenare Efbe-schott
- Luftrenare Venta
- Luftrenare Thermex
- Luftrenare Bimar
- Luftrenare Be Cool
- Luftrenare Turmix
- Luftrenare Fakir
- Luftrenare Blueair
- Luftrenare Laserliner
- Luftrenare Vornado
- Luftrenare Sonnenkonig
- Luftrenare AENO
- Luftrenare REMKO
- Luftrenare Clean Air Optima
- Luftrenare TruSense
- Luftrenare Oreck
- Luftrenare Zepter
- Luftrenare Instant
- Luftrenare Whynter
- Luftrenare Kalorik
- Luftrenare Gutfels
- Luftrenare Klarbach
- Luftrenare Crane
- Luftrenare Qlima - Zibro
- Luftrenare LTC
- Luftrenare Galanz
- Luftrenare IQAir
- Luftrenare Duracraft
- Luftrenare Brondell
- Luftrenare Queenaire
- Luftrenare Moneual
- Luftrenare Kogan
- Luftrenare Lenoxx
- Luftrenare Uni-T
- Luftrenare GermGuardian
- Luftrenare MSR
- Luftrenare SPT
- Luftrenare Lentz
- Luftrenare IonizAir
- Luftrenare LightAir
- Luftrenare Heaven Fresh
- Luftrenare Airthereal
- Luftrenare PURIFY
- Luftrenare Djive
- Luftrenare TruSens
- Luftrenare Dri Eaz
- Luftrenare NEO Tools
- Luftrenare Ravanson
- Luftrenare E.ziclean
- Luftrenare Zedar
- Luftrenare Nevoox
- Luftrenare Stylies
- Luftrenare House & Luft
- Luftrenare Woods
- Luftrenare Blue Air
- Luftrenare Guardian
- Luftrenare RainbowAir
- Luftrenare Lifeair
- Luftrenare Periso
- Luftrenare Beghelli
- Luftrenare ASIGO
- Luftrenare P3 International
- Luftrenare Luma Comfort
- Luftrenare Brentwood
- Luftrenare Ionmax
- Luftrenare Greentec
- Luftrenare Meross
- Luftrenare Airo
- Luftrenare MANN+HUMMEL
- Luftrenare Airocide
- Luftrenare SHE
- Luftrenare PRIMAVERA
- Luftrenare OZONOS
- Luftrenare Welcare
- Luftrenare Coplax
- Luftrenare DH Lifelabs
- Luftrenare Hacienda
- Luftrenare FilterStream
- Luftrenare Aconatic
- Luftrenare Arovec
- Luftrenare Imarflex
- Luftrenare Perfect Aire
- Luftrenare Ulsonix
Nyaste Luftrenare Manualer
27 Oktober 2024
27 Oktober 2024
23 Oktober 2024
21 Oktober 2024
19 Oktober 2024
18 Oktober 2024
18 Oktober 2024
17 Oktober 2024
17 Oktober 2024
17 Oktober 2024