USER’S MANUAL
2
REMARKS ABOUT SAFETYSAVE THESE INSTRUCTIONS
In order to keep safe in using the UPS, please comply with the
following:
•Pleasechargethebatteryatleast12hoursbeforetheUPSisin
operation.
•Afterthebatteryisdischargedoroverthreemonthswithout
operarion,thebatteryshouldbechargedimmediatelyforatleast
12hours,ensuringthebatteryisfullandavoidinganyunnecessary
damageofthebattery.
•WhenACfailsandtheONbuttononthefrontpanelispressed,
theUPSwilloutputvoltage;iftheOFFbuttononthefrontpanelis
pressed,theUPSwillnotoutputvoltage.
This manual contains important safety instructions. Please follow
all instructions carefully during installation. Read this manual
thoroughlybeforeattemptingtounpack,installoroperate.
CAUTION Topreventtheriskofreorelectricshock,installina
temperature and humidity controlled indoor area, free
ofconductivecontaminants.
CAUTION Riskofelectricshock,donotremovethecover.Nouser
serviceableparts.Referservicingtoqualiedservice
personnel.
CAUTION Riskofelectricshock,hazardouslivepartsinsidethis
UPScanbeenergizedfromthebatterysupplyeven
when the input AC power is disconnected.
CAUTION Risk of electric shock, Battery Circuit is not isolated from
ACinput;hazardousvoltagemayexistbetweenbattery
terminalsandground.Testbeforetouching.
WARNING This is a Class A-UPS Product. In a domestic
environment,thisproductmaycauseradiointerference,
inwhichcase,theusermayberequiredtotake
additional measures.
NOTICE TheUPSisdesignedtobeforusewithcomputer
loads only.
NOTICE Topreventinjury,donotcarrywiththehandleoffront
coverwhenmovingtheUPS.
ENGLISH
3
MODEL SPECIFICATIONS INTRODUCTION
FORTRESSBUNKER 600VA/360W Battery:1x12V/7Ah
1.BatterychargingLed:itlitswhentheUPSispluggedtothemains.
2. Power failure Led: it lits when the UPS detects a power cut.
3.IndicatesoverloadinUPS.AlsoindicatesthattheUPSwillshut
down in less than thirty seconds when there is a power cut.
4.ON/OFFbutton:turnsUPSonando.
Press and release to turn on
 Pressandreleasetoturno
MAIN SPECIFICATIONS
Model FORTRESS BUNKER
DCvoltageinbatterymode 12V
Type of load Computer, displayer
Inputvoltage 230V
Inputfrequency 50Hz
Outputvoltage 230V
Outputfrequency 50/60Hz
Power factor PF=0.6 (when input range -35%
to -23%, PF=0.45)
Backup time 5-10minutes(dependsofthe
load)
Transfer time 10ms
Short-circuit protection Circuitbreaker,limitedoutput
currencyininvertermode
Eciency of power >80%ininvertermode
Temperature 0°C ~ 40°C
Humidity 10%~90%
Display LED display: AC, charging,
inverting
312
4